Show simple item record

dc.contributor.advisorUlusoy, Mutahhar
dc.contributor.authorAkgök, Vacide
dc.date.accessioned2020-12-04T11:51:31Z
dc.date.available2020-12-04T11:51:31Z
dc.date.submitted1992
dc.date.issued2018-08-06
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/81257
dc.description.abstract80 SUMMARY The comparison of bilateral and unilateral prosthesis designs used in Kennedy Class- II cases from the view point of retention and stability. Various bilateral and unilateral prosthesis designs used in Kennedy Class-II unilate¬ ral free end cases have been compared for their retention and stability in this investigation. Nine mandibular models of Kennedy Class-II partially edentulous case have been prepared from the photoelastic material for the stability and stress analysis tests. Three groups of unilateral and six groups of bilateral framework designs were made on the models and the castings were done and finished with the routine techniques. These models were loaded under special conditions for the three dimensional stress analysis. in this technique, parallel sections of models were analysed under polarized light in Polariscope and then the photographs were taken. Number of fringes on the photographs were counted and evaluated. in addition the results were shown with graphics and compared with each other. On the other hand, Kennedy Class-II mandibular model from acrylic resin was pre¬ pared and the framevvork designs rneııtioned above were done for the retention tests. Each framevvork was tested ten times to measure tensile forces and to define the strength of the force resisting to remove the prosthesis and the results were evaluated statistically.
dc.description.abstract80 SUMMARY The comparison of bilateral and unilateral prosthesis designs used in Kennedy Class- II cases from the view point of retention and stability. Various bilateral and unilateral prosthesis designs used in Kennedy Class-II unilate¬ ral free end cases have been compared for their retention and stability in this investigation. Nine mandibular models of Kennedy Class-II partially edentulous case have been prepared from the photoelastic material for the stability and stress analysis tests. Three groups of unilateral and six groups of bilateral framework designs were made on the models and the castings were done and finished with the routine techniques. These models were loaded under special conditions for the three dimensional stress analysis. in this technique, parallel sections of models were analysed under polarized light in Polariscope and then the photographs were taken. Number of fringes on the photographs were counted and evaluated. in addition the results were shown with graphics and compared with each other. On the other hand, Kennedy Class-II mandibular model from acrylic resin was pre¬ pared and the framevvork designs rneııtioned above were done for the retention tests. Each framevvork was tested ten times to measure tensile forces and to define the strength of the force resisting to remove the prosthesis and the results were evaluated statistically.en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/embargoedAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectDiş Hekimliğitr_TR
dc.subjectDentistryen_US
dc.titleKennedy class II vak`alarında kullanılan bilateral ve unilateral protez tasarımlarının retansiyon ve stabilite bakımından mukayeseleri
dc.typedoctoralThesis
dc.date.updated2018-08-06
dc.contributor.departmentDiğer
dc.subject.ytmDenture retention
dc.subject.ytmDenture design
dc.identifier.yokid23970
dc.publisher.instituteSağlık Bilimleri Enstitüsü
dc.publisher.universityANKARA ÜNİVERSİTESİ
dc.identifier.thesisid23970
dc.description.pages87
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/embargoedAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/embargoedAccess