Show simple item record

dc.contributor.advisorÖzdemir, Hakan
dc.contributor.authorSuna, Özhan
dc.date.accessioned2020-12-29T08:46:27Z
dc.date.available2020-12-29T08:46:27Z
dc.date.submitted1998
dc.date.issued2018-08-06
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/371002
dc.description.abstract68 VH. ÖZET: Amaç: Sinovial sıvı miktarı hastalıkların önemli bir göstergesi olduğu için, bazal normal verileri sağlamak üzere, ayak ve ayak bileğinde, sinovial sıvının volümetrik ölçümleri yapıldı. Gereç ve Yöntem: Hacim verileri, 20 asemptomatik gönüllü üzerinde (25-61 yaş), 40 ayak bileğinde, 7-10 MHz 3D probu (Voluson 530D, Medison-America) kullanılarak elde edildi. Eklem reseleri, bursa ve tendon kılıflarındaki sıvı miktan değerlendirildi. Görüntüler sagittal planda elde edildi ve üç ortogonal planda rekonstrükte edildi: transvers, sagittal, ve koronal. Sıvı hacimleri, hacim veri setinden manüel planimetrik yöntem kullanılarak hesaplandı. Bulgular: Tendon kılıflarında sıvı, en sık olarak peronealler etrafinda izlendi (%57.5, ortalama 0.039 mi), ve önceki MR sonuçlarının tersine fleksörler etrafinda daha az sıktı. Fleksör grupta sıvı, fleksör hallusis longus tendonu çevresinde en sık (%50, ortalama 0.03 ml), tibialis posterior tendonu etrafında daha az sık (%47.5, ortalama 0.015 mi), ve fleksör digitorum longus tendonu etrafında nadir (%12.5, ortalama 0.02 mi) idi. Ekstensör grupta, sıvı daha seyrekti, ancak bulunduğu zaman, özellikle de ekstensör hallusis longus tendonu etrafinda hacirni daha fazlaydı (%10, ortalama 0.116 mi). Sıvı tibialis anterior tendonu çevresinde en sık (%17.5, ortalama 0.067 mi), ve ekstensör digitorum longus tendonu etrafinda nadir idi (%7.5, ortalama 0.015 mi). Retrokalkaneal bursaların çoğunda çok az miktarlarda sıvı izlendi (%75, ortalama 0.005 ml). Anterior eklem resesinde sıvı oldukça sıktı (%65, ortalama 0.04 ml). Posterior eklem resesinde sıvı pek sık görüntülenmedi (%15). Sonuç: 3D US, normal ayak ve ayak bileğinde sıvı hacimi ölçümlerine olanak verir. Bu çalışmada normal veri sağlandı.
dc.description.abstract69 Vm. ABSTRACT: Purpose: Since synovial fluid is an important marker of disease, we performed 3-D US volumetric measurements of synovial fluid to provide baseline normative data. Materials and Methods: Volume data were acquired using a dedicated 7-10 MHz 3-D probe on 40 ankles in 20 volunteers (25-61 years). Amounts of fluid were assessed in the ankle joint recesses, bursae and tendon sheaths. Images were acquired in the sagittal plane and were reconstructed in three orthogonal planes; transverse, sagittal and coronal. Fluid volumes were calculated from the volume data set using the manual planimetric method. Results: Fluid in tendon sheaths was most common about the peroneals (57.5%, mean 0.039 ml), and unlike prior MR results was less common about the flexors. In the flexors fluid was most common about the flexor hallucis longus tendon (50%, mean 0.03 ml), less common around posterior tibial tendon (47.5%, mean 0.015 ml), and rare about fleksor digitorum longus tendon (12.5%, mean 0.02 ml). In the extensors, fluid was less common but when present of greater volume, especially about the extensor hallucis longus tendon (10%, mean 0.116 ml). Fluid was most common about the anterior tibial tendon (17.5%, mean 0.067 ml) and rare around extensor digitorum longus tendon (7.5%, mean 0.015 ml). Sparse fluid was seen in the majority of retrocalcaneal bursae (75%, mean 0.015 ml). Fluid in anterior ankle recess was quite common (65%, mean 0.04 ml). Visualization of fluid in the posterior ankle recess was infrequent (15%). Conclusion: 3-D US permits measurement of fluid volume in the normal ankle/hindfoot; normative data are provided.en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/embargoedAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectRadyoloji ve Nükleer Tıptr_TR
dc.subjectRadiology and Nuclear Medicineen_US
dc.titleAyak ve ayak bileğinde sinovial sıvının 3D ultrason ile volümetrik değerlendirilmesi: Teknik ve normal veri
dc.title.alternative3D ultrasound volumetric assesment of the synovial fluid about the ankle and foot: Technique and normative data
dc.typedoctoralThesis
dc.date.updated2018-08-06
dc.contributor.departmentDiğer
dc.subject.ytmAnkle
dc.subject.ytmUltrasonography
dc.subject.ytmSinovial fluid
dc.identifier.yokid69975
dc.publisher.instituteTıp Fakültesi
dc.publisher.universityGAZİ ÜNİVERSİTESİ
dc.type.submedicineThesis
dc.identifier.thesisid69975
dc.description.pages76
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/embargoedAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/embargoedAccess