Show simple item record

dc.contributor.advisorÖzdemir, Hakan
dc.contributor.authorÖzbek, Erdal Halil
dc.date.accessioned2020-12-29T08:46:25Z
dc.date.available2020-12-29T08:46:25Z
dc.date.submitted1998
dc.date.issued2018-08-06
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/370990
dc.description.abstractÖZET AMAÇ: Ultrason kontrast ajanı olarak EchoGen'in, karaciğer kitle lezyonlarında benign- malign ayırıcı tanısına olan etkinliği ve güvenirliliğini araştırmak GEREÇ ve YÖNTEM: EchoGen'in güvenirlik ve etkinliğini değerlendiren, multisentrik uluslararası faz Illb çalışma kapsamında kliniğimizde, 24 karaciğer lezyonlu (5 hemanjiom, 1 fokal nodüler hiperplazi, 3 hepatoselüler karsinom ve 15 metastatik karaciğer tümörü) 20 hastaya 'EchoGen' uygulaması gerçekleştirildi. Üç hemanjiom ve 1 olgudaki fokal nodüler hiperplazi hariç tüm olgularda histopatolojik tanı konurken, histopatolojik tanı konamayan olgularda tanı klinik izlem, tipik BT ve MR bulguları ile desteklendi. EchoGen'in 0.05 ml/kg olacak şekilde, enjeksiyonu öncesi ve sonrası power ve renkli Doppler incelemeler gerçekleştirildi. Lezyonların vaskülarizasyonları akım paternlerinin dağılımı ve miktarlarına göre her ultrasonografık incelemede sınıflandırıldı. BULGULAR: Hepatoselüler karsinom olgularının hepsinde tümör dokusunun periferal ve santral kesimlerinde kontrast sonrası güçlü sinyal intensiteleri tespit edildi. Orta şiddette yada güçlü akım sinyalleri 15 metastatik olgunun 10'unda saptandı. Fokal nodüler hiperplazi olgusu özellikle santral kesimde belirgin vaskülarizasyon artışı gösterdi. Hemanjiomlarda enjeksiyon sonrası kontrast tutulumu saptanmadı. TARTIŞMA ve SONUÇ: EchoGen uygulamasını takiben tumoral kanlanma artışı malign tümör varlığını düşündürmektedir. Enjeksiyon sonrası lezyonda akım sinyallerinin izlenmemesi benign tümörlerde sıklıkla görülmekle birlikte malignensi varlığını ekarte ettirmez.
dc.description.abstract70 Vm. ABSTRACT VALUE OF ECHOGEN-ENHANCED POWER & COLOR DOPPLER SONOGRAPHY IN DIFFERENTIATING LIVER TUMOURS Purpose: To evaluate the efficacy and safety of EchoGen, an investigational ultrasound contrast-enhancing agent, in separating benign from malignant liver masses. Methods and Materials: During Phase Illb multicentric trial of EchoGen, twenty patients with 24 liver lesions(5 haemangiomas, 1 focal nodular hyperplasias, 3 hepatocellular carcinomas and 15 metastases) were evaluated prospectively. Histological verification was obtained in all liver lesions, except in three haemangiomas and one focal nodular hyperplasias, where CT and MR imagings were regarded as sufficient proof. Power and color Doppler ultrasound was performed before and after intravenous injection of 0.05 ml/kg of EchoGen. Vascularization of the lesions classified according to the distrubition and amount of flow pattern in each sonographic examination. Results: In three patients with hepatocellular carcinoma strongly enhanced signal intensity was observed in all patients both in the central and peripheral portion of the tumor. Moderate or strong flow signals were detected after contrast injection in 10/15 metastatic tumors. One patient with focal nodular hyperplasias showed strong signal enhancement in the central area of the tumor. No signal enhancement was observed in haemangiomas. Conclusion: Following Echogen administration, enhanced intratumoural flow signals favour a malignant tumor. While, the absence of flow signals is a frequent finding in benign lesions, it does not rule out malignancyen_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/embargoedAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectRadyoloji ve Nükleer Tıptr_TR
dc.subjectRadiology and Nuclear Medicineen_US
dc.titleKaraciğer kitle lezyonlarının renkli ve power renkli doppler ultrasonografi ile değerlendirilmesinde ultrason kontrast ajanı olarak Echoge`nin yeri
dc.title.alternativeValue of echogen enhanced power and color doppler sonography in differentiating liver tumours
dc.typedoctoralThesis
dc.date.updated2018-08-06
dc.contributor.departmentDiğer
dc.subject.ytmUltrasonography
dc.subject.ytmContrast media
dc.subject.ytmLiver
dc.identifier.yokid69981
dc.publisher.instituteTıp Fakültesi
dc.publisher.universityGAZİ ÜNİVERSİTESİ
dc.type.submedicineThesis
dc.identifier.thesisid69981
dc.description.pages78
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/embargoedAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/embargoedAccess