Üç farklı kimyasal bağlantı sisteminin metal-rezin bağlanma dayanıklılığının in vitro koşullarda karşılaştırmalı olarak incelenmesi
dc.contributor.advisor | Nalbant, Levent | |
dc.contributor.author | Kamaci, Kamelya | |
dc.date.accessioned | 2020-12-29T08:16:12Z | |
dc.date.available | 2020-12-29T08:16:12Z | |
dc.date.submitted | 2000 | |
dc.date.issued | 2018-08-06 | |
dc.identifier.uri | https://acikbilim.yok.gov.tr/handle/20.500.12812/359003 | |
dc.description.abstract | -91- ÖZET Bu çalışmada, üç kimyasal bağlantı sistemi ve bu sistemlere ait ışıkla polimerize olan kompozit rezin materyalinin (Targis Link / Targis, Siloc Relink / Artglass ve Vita Zeta HLC / Vita Zeta), kıymetsiz metal alaşımlarla (Rematitan, Remanium 2000, Remanium CS) yaptığı bağlantının kesme tipi kuvvetlere karşı bağlanma dayanıklılığı değerlendirildi. Test için 60 adet Targis Link / Targis, 60 adet Siloc Relink / Artglass ve 60 adet Vita Zeta HLC / Vita Zeta olmak üzere toplam 180 örnek hazırlandı. ISO 10477 standardına göre hazırlanan metal-rezin test örneklerinin yarısı 37 ± 3 °C lik distiie suda 24 saat bekletilip kesme testi uygulandı. Diğer yansı 37 ± 3 `C'de distiie suda 1 hafta bekletilip termosiklus işlemi uygulandı ve tensometrede (Hounsfieıd) kesme testi yapıldı. Sonuç olarak; çalışmamızda, metal alaşımları arasında kesme kuvvetine karşı bağlanma dayanıklılığı açısından, termosiklus uygulanmış ve uygulanmamış örnek grupları arasında ve grupların kendi içinde istatistiksel olarak anlamlı bir fark bulunmadı (P>0,05). Kimyasal bağlantı sistemlerinin kesme kuvvetine karşı bağlanma dayanıklılığı arasındaki fark termosiklus uygulanmış ve uygulanmamış örnek gruplarında, istatistiksel olarak anlamlı bulundu (P<0,05).Termosiklus uygulanmış örnek grupları ve termosiklus uygulanmamış örnek grupları arasında kesme kuvvetlerine karşı bağlanma dayanıklılı arasındaki fark üç kimyasal bağlantı sisteminde de istatistiksel olarak anlamlı bulundu (P<0,05). Kesme testinden sonra, mikroskobik yüzey incelemesinde termosiklus uygulanmış örnek gruplarında uygulanmamış örnek gruplarına göre adeziv kopma yüzeylerinde artış olduğu gözlendi. | |
dc.description.abstract | -92- SUMMARY in this study, shear bond strengths of metal-resin interface between three chemical bonding systems (Targis Link / Targis, Siloc / Relink / Artglass and Vita Zeta HLC / Vita Zeta) and nonprecious metal alloys (Rematitan, Remanium 2000, Remanium CS) were evaluated. For the shear testing, totally 180 metal-resin specimens (60 Targis Link / Targis, 60 Siloc Relink / Artglass and 60 Vita Zeta HLC / Vita Zeta) were prepared. Half of the specimens which were prepared according to ISO 10477 standards were stored in distilled water at 37±3°C for 24 hours and then shear test were performed. The other half of the specimens were stored in distilled water at 37±3°C for one week and after thermocycling, tha bonds were fractured in shear on a Instron testing machine. The results of the study have shown that; the bond strengths at the shear tests between the metal alloys didn't show significant differences in the thermocycled and non- thermocycled groups (p>0,05). The bond strengths between the chemical bonding systems at the shear tests showed significant differences in termocycled and non- thermocycled specimen groups (p<0,05). The bond strengths between thermocycled and non-thermocycled groups in the three chemical bonding systems showed significant differences at the shear tests (p<0,05). After the shear tests microscopic surface examinations were made in both thermocycled and non thermocycled specimen groups. There was an increase of adhesive failure at the metal-resin interface in the thermocycled specimen groups. | en_US |
dc.language | Turkish | |
dc.language.iso | tr | |
dc.rights | info:eu-repo/semantics/embargoedAccess | |
dc.rights | Attribution 4.0 United States | tr_TR |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject | Diş Hekimliği | tr_TR |
dc.subject | Dentistry | en_US |
dc.title | Üç farklı kimyasal bağlantı sisteminin metal-rezin bağlanma dayanıklılığının in vitro koşullarda karşılaştırmalı olarak incelenmesi | |
dc.title.alternative | In vitro comparison of the shear bond strengths of metal to resin in three different chemical bonding systems | |
dc.type | doctoralThesis | |
dc.date.updated | 2018-08-06 | |
dc.contributor.department | Diğer | |
dc.subject.ytm | Dental porcelain | |
dc.subject.ytm | Composite resins | |
dc.subject.ytm | Crowns | |
dc.subject.ytm | Alloys | |
dc.subject.ytm | Dental materials | |
dc.subject.ytm | Dental cements | |
dc.identifier.yokid | 90505 | |
dc.publisher.institute | Sağlık Bilimleri Enstitüsü | |
dc.publisher.university | GAZİ ÜNİVERSİTESİ | |
dc.identifier.thesisid | 90505 | |
dc.description.pages | 107 | |
dc.publisher.discipline | Diğer |