Show simple item record

dc.contributor.advisorEğilmez, Ferhan
dc.contributor.authorAçar, Burcu
dc.date.accessioned2020-12-29T07:43:46Z
dc.date.available2020-12-29T07:43:46Z
dc.date.submitted2016
dc.date.issued2018-12-05
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/348491
dc.description.abstractAmaç: Bu çalışmanın amacı; farklı yüzey işlemlerinin 3 farklı estetik CAD-CAM materyalinin yüzey pürüzlülüğü ve renk stabilitesine etkisinin değerlendirilmesidir. Gereç-Yöntem: Çalışmada nano hibrit ve polimer infiltre seramik ağ yapılı CAD-CAM bloklardan 70'er adet örnek hazırlanmıştır (n=210). Örnekler uygulanan polisaj işlemlerine göre 5 alt gruba ayrılmıştır (n=14/grup). Grup 1: Alüminyum oksit içerikli bitirme ve polisaj diski (Sof-Lex Disk), Grup 2: Silikon cila lastiği, Grup 3: Elmas dolduruculu polisaj patı (Diapolisher Paste), Grup 4: Elmas içerikli cila diski (Diacomp Plus Twist), Grup 5 (Kontrol): Zımpara (#1000 ve #4000 gridlik SiC kağıdı). Yüzey pürüzlülüğü ölçümü yapılan örneklerin yarısı ısısal döngü (5000 döngü, 5°-55°C) işlemine tabi tutulmuştur. Renk ölçüm işleminde ise örneklerin tümünün birinci renk ölçümleri yapılmıştır. Daha sonra örneklerin tümü ısısal döngü işlemine tabi tutulmuş ve ikinci renk ölçümleri yapılmıştır. Test örneklerinin renk stabilite sonuçları (∆E00) Kruskal-Wallis ve Mann-Whitney U testleri ile; yüzey pürüzlülüğü (Ra) sonuçları ise ANOVA ve Tukey çoklu karşılaştırma testleri ile değerlendirilmiştir (p<0,05). Bulgular: Isısal döngü işlemi sonrası ∆E00 değerleri açısından hem estetik CAD-CAM materyalleri hem de polisaj materyalleri arasında anlamlı fark bulunmuştur (p<0,05). Vita Enamic materyali Lava Ultimate materyalinden belirgin olarak daha fazla renk değişimi göstermiştir (Z=-3,256; p<0,05). Ayrıca en fazla renk değişimi elmas içerikli cila diski ile polisaj yapılan materyallerde görülmüştür (p<0,05). Ra değerleri açısından CAD-CAM materyalleri arasında fark bulunmazken (F=0,948; p=0,389), polisaj işlemleri arasında anlamlı bir farklılık bulunmuştur (F=158,309; p<0,001). Isısal döngü işleminin Ra değerleri üzerinde bir etkisi olmadığı saptanmıştır (F=0,03; p=0,863). Çoklu karşılaştırma sonuçlarına göre polisaj yöntemlerine ait Ra değerleri silikon cila lastiği grubunda en yüksek bulunmuştur (p<0,05). Sonuç: Termal siklus sonrası nano hibrit CAD-CAM materyalleri polimer infiltre seramik ağ yapılı materyalden daha iyi sonuç verirken CAD-CAM materyallerin elmas cila diski ile polisajı renk değişimi açısından uygun görünmemektedir. Silikon cila lastiği ise estetik CAD-CAM materyallerde yüksek yüzey pürüzlülüğüne neden olmaktadır.
dc.description.abstractAIM: The aim of this study was to evaluate the effect of different surface finishing procedures on the surface roughness and color stability of three different aesthetic CAD-CAM Materials. MATERIALS-METHODS: In the study present 70 specimens from each of nano-hybrid and polymer infiltrated ceramic network structured CAD-CAM blocks (Lava Ultimate, Cerasmart, Vita Enamic) were prepared (n=210). The specimens were divided into 5 sub-groups according to the applied polishing procedure (n=14/group). Group 1: Finishing and polishing disc (Sof-Lex Disk), Group 2: Silicone rubber polisher, Group 3: Polishing paste with diamond filler (Diapolisher Paste), Group 4: Diamond polishing disc (Diacomp Plus Twist), Group 5: Sandpaper (#1000 ve #4000 grid SiC paper) as control. For surface rougness measurements, half of the specimens in each group were submitted to the thermal cycling (5000 cycles, 5°-55°C). For color stability measurements, first color measurements of all samples were done. Then, all of the samples were submitted to thermal cycling and second color measurements were performed. ANOVA and Tukey multiple comparison tests and were used for the evaluation of surface roughness (Ra) data. Kruskal-Wallis and Mann-Whitney U tests were used for the evaluation of color stability (∆E00) data (p<0.05). RESULTS: Significant differences in ∆E00 data were found among CAD-CAM materials and polishing procedures after thermal cycling (p<0.05). Vita Enamic exhibited significantly higher color change than Lava Ultimate (Z=-3,256; p<0.05). Besides, the most color change was found in the materials polished with diamond polishing discs (p<0.05). No significant difference was found in Ra data amongst CAD-CAM materials (F=0.948; p=0.389), whereas significant difference was determined among polishing procedures (F=158.309; p<0.001). Thermal cycling did not affect Ra values (F=0.03; p=0.863). According to the multiple comparison results, Ra data in polishing procedures was found the highest in silicone rubber polisher. (p<0.05).CONCLUSION: Better results were obtained with nano hybrid CAD-CAM materials than polymer infiltrated ceramic network material in following thermal cycling. In addition, polishing CAD-CAM materials with diamond polishing discs did not seem an appropriate procedure in terms of color stability. Polishing with silicone rubber polisher resulted in higher surface roughness.en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectDiş Hekimliğitr_TR
dc.subjectDentistryen_US
dc.titleFarklı yüzey işlemlerinin cad-cam materyallerin yüzey pürüzlülüğü ve renk stabilitesi üzerine etkilerinin değerlendirilmesi
dc.title.alternativeEffect of different surface finishing procedures on the surface roughness and color stability of cad-cam materials
dc.typedoctoralThesis
dc.date.updated2018-12-05
dc.contributor.departmentProtetik Diş Tedavisi Anabilim Dalı
dc.identifier.yokid10129425
dc.publisher.instituteDiş Hekimliği Fakültesi
dc.publisher.universityGAZİ ÜNİVERSİTESİ
dc.type.subdentistThesis
dc.identifier.thesisid521919
dc.description.pages140
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess