Show simple item record

dc.contributor.advisorGül, Ferhat
dc.contributor.authorÇetin, Melik
dc.date.accessioned2020-12-10T13:51:10Z
dc.date.available2020-12-10T13:51:10Z
dc.date.submitted2005
dc.date.issued2018-08-06
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/303032
dc.description.abstractÖZET EMPERLENMİŞ KÜRESEL GRAFİTLİ DÖKME DEMİRLERİN AŞINMA DAVRANIŞLARININ GELİŞTİRİLMESİ (Doktora Tezi) MELİK ÇETİN GAZİ ÜNİVERSİTESİ FEN FİLİMLERİ ENSTİTÜSÜ Mart 2005 ÖZET Bu araştırmada, döküm durumu yapısı ferritîk ve perlitik olan östemperlenmiş küresel grafiti! dökme demirlerde (ÖKGDD) östenitleme sıcaklığı ve süresi ile östemperleme sıcaklığı ve süresinin sonuç mikroyapısına, sertliğine ve aşmma davranışına, aşmma sırasında oluşan sürtünme kuvvetine ve pim sıcaklığına olan etkisi araştırılmıştır. Bu amaçla, döküm durumu yapısı ferritik ve perlitik olan küresel grafitli dökme demirler 850°C ve 900°C'de 30, 60 ve 90 dakika östenitleme işleminden sonra 250°C, 320°C 370°C ve 400°C'de 60 ve 120 dakika östemperlenmiştir. Mikroyapısal karakterizasyon işlemleri optik mikroskop ile yapılmıştır. ÖKGDD numunelerin sertlikleri oda sıcaklığında belirlenmiştir. Aşmma deneyleri, disk üzerinde pim cihazında, kuru kayma şarlarmda AISI 5190 çelik disk (62 HRC) üzerinde, 1 m/s doğrusal kayma hızında, 20, 40 ve 60 N yükler altında ve 3600 m kayma mesafesinde gerçekleştirilmiştir. Deneylerin tamamı normal atmosferde, oda sıcaklığında gerçekleştirilmiş olup aşınmış yüzeyler, tarama elektron mikroskobu (SEM) ile incelenmiştir. İncelenen ÖKGDD numunelerin sertliği, östenitleme sıcaklığı ve süresinin artmasıyla ve östemperleme sıcaklığının azalması ile artmıştır. Deneysel sonuçlar; 850°C'de 30 dk östenitlemeden sonra 250°C'de 60 dakikan fazla östemperleme yapılmasının, her iki grup numunenin sertliğini düşürdüğünügöstermiştir. 850°C'de ostenitlenen numunelerin aşmma kaybı, uygulanan tüm yüklerde ostemperleme sıcaklığının ve ostenitleme süresinin artması ile azalmıştır. 900°C'de ostenitlenen numunelerin aşınma kaybı ise uygulanan tüm yüklerde ostemperleme sıcaklığının ve ostenitleme süresinin artmasıyla artmıştır. 850°C ve 900°C'de 30, 60 ve 90 dakika östenitlemeden sonra 250°C ve 320°C'de ostemperlenen döküm durumu yapısı ferritik ve perlitik KGDD'lerin aşınma dirençlerinin 370 ve 400°C sıcaklıklarda ostemperlenen her iki grup numuneden daha fazla iyileştiği görülmüştür. Aşmma performansının iyileşmesinde, mikroyapıda bulunan küresel grafitlerin yağlayıcı gibi davranmalarının, ösferritik yapı ile başlangıç sertliğinin artmasının, aşmma deneyi sırasında plastik deformasyonla yüksek karbonlu östenitin martensite dönüşmesinin ve yüzeyin pekleşmesinin etkili olduğu düşünülmüştür. Yüksek sıcaklıklarda ostemperlenen ÖKGDD numunelerin sürtünme katsayısı, düşük sıcaklıklarda östemperlenenlere göre daha yüksek olduğu tespit edilmiştir. Aşmma deneylerinde, ÖKGDD numunelerin yüzey sıcaklığının artmasıyla numunelerin sürtünme kuvvetlerinin düştüğü tespit edilmiştir. SEM incelemelerinden ÖKGDD' in kuru kayma aşınmasında baskın aşınma mekanizmasının plastik akma, delaminasyon ve oksidasyonun malzeme kaybında etkili olduğu görülmüştür. Oluşan oksitler, deney sürecinde sertleşerek abrasifler gibi davranış sergilemişlerdir. Döküm durumu KGDD'Ierde aşmma temel olarak, yüzey adhesyonu ve plastik deformasyonun malzeme kaybında etkili olduğu görülmüştür. Bilim kodu : 626.17.01 Anahtar Kelimeler : Östemperlenmiş küresel grafitli dökme demir (ÖKGDD), Isıl işlem, Mikroyapı, Sertlik, Adhesif Aşmma, Sürtünme Kuvveti, Pim Sıcaklığı Sayfa Adedi : 246 Tez Yöneticisi : Yrd-Doç. Dr. Ferhat GÜL
dc.description.abstractm THE IMPROVEMENT OF WEAR BEHAVIOUR OF AUSTEMPERED DUCTILE IRONS (PhD Thesis) Melik ÇETİN GAZI UNIVERSITY INSTITUTE OF SCD2NCE AND TECHNOLOGY March 2005 ABSTRACT An investigation was carried out to examine the influence of austenizing temperature and time together with austempering temperature and time on the resultant microstructure, hardness, wear behaviour, friction force and pin temperature of as-cast ferritic and as-cast pearlitic structure of austempered ductile irons (ADI). For this purpose, as-cast ferritic and as-cast pearlitic ductile cast irons were austenitized at 850°C and 900°C for 30, 60 and 90 min and subsequently austempered for 60 and 120 minutes at 250°C, 320°C, 370°C and 400°C. Microstructural characterizations were carried out by optical microscopy examinations. Hardness of the ADIs were determined at room temperature. The wear tests were carried out using a pin-on-disc type apparatus at dry sliding conditions. The wear specimens were rubbed against the hardened AISI 5190 steel disc (62 HRC) at a linear sliding speed of İm s`1, under the loads of 20N, 40N and 60N and sliding distance of 3600m. All tests were performed in ambient air at room temperature. The worn surface of the specimens were examined by scanning electron microscope (SEM). The hardness of the investigated ADI specimens increased with increasing austenitising temperature and time and decreasing austempering temperature. The results indicated that the austempering time above 60 min at 250°C afterIV austenitising at 850°C for 30 min had a detrimental effect on the hardness of both as-cast ferritic and perlitic ductile iron specimens. Wear loss of the specimens austenitised at 850°C decreased with increasing austempering temperature and increasing austenitising time for all the applied loads. Wear loss of the specimens austenitised at 900°C increased with increasing austempering temperature and austenitising time for all the applied loads. The results obtained showed that austempering at 250°C and 320°C after austenitising at 850°C and 900°C for 30,60 and 90 minute improved the wear resistances of the as-cast ferritic and as-cast pearlitic ductile irons more than the both groups austempered at 320°C and 400°C. The improvement in wear performance was explained by the lubricity inherent in the graphite nodules, the increase in initial hardness caused by the ausferritic structure, and the work hardening of the surface as high carbon austenite is transformed to martensite by plastic deformation. It is also found that the ADIs austempered at higher temperatures had higher friction coefficient than those austempered at low temperatures. With increasing surface temperatures of the ADIs during the wear tests, the friction forces decreased. Scanning electron microscopy (SEM) examinations revealed that the dominant wear mechanisms in dry sliding of the ADIs were plastic yield, delemination and oxidation. All these mechanisms were found to be effective in wear losses. The formed oxides were hardened during the tests and acted like abrasives. For the as cast DIs, surface adhesion and plastic deformation were basically found to be responsible from the wear losses. Science code : 626.17.01 Key words : Austempered ductile iron (ADI), Heat treatment, Microstructure, Hardness, Adhesive wear, Friction force, Pin temperature Page number : 246 Adviser : Assist. Prof.Dr. Ferhat GÜLen_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectMetalurji Mühendisliğitr_TR
dc.subjectMetallurgical Engineeringen_US
dc.subjectTeknik Eğitimtr_TR
dc.subjectTechnical Educationen_US
dc.titleÖstemperlenmiş küresel grafitli dökme demirlerin aşınma davranışlarının geliştirilmesi
dc.title.alternativeThe improvement of wear behavior of austempered ductile irons
dc.typedoctoralThesis
dc.date.updated2018-08-06
dc.contributor.departmentMetal Eğitimi Anabilim Dalı
dc.identifier.yokid186543
dc.publisher.instituteFen Bilimleri Enstitüsü
dc.publisher.universityGAZİ ÜNİVERSİTESİ
dc.identifier.thesisid165960
dc.description.pages272
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess