dc.description.abstractBu çalışmanın amacı, farklı kalınlıklardaki CAD/CAM seramik kesitlerinin iki farklı rezin simanın polimerizasyonuna olan etkisini değerlendirmektir. Üç farklı CAD/CAM ile işlenebilen tam seramik restorasyon materyali (IPS Empress, Vita Enamic, Vita Suprinity), dört farklı kalınlığa sahip olacak şekilde (0.5, 1, 1.5, 2 mm) düşük hızlı hassas kesme cihazında kesildi. Her seramik kesiti altında gerçekleştirilen polimerizasyon ile ışık ile polimerize olan rezin siman ve hem kimyasal hem de ışık ile polimerize olan rezin simandan toplam 240 örnek hazırlandı ve 24 saat boyunca 37 °C'de ışık almayacak şekilde saklandı. Tüm örnekler, dönüşüm derecelerinin belirlenebilmesi amacıyla FTIR analizi ile test edilerek 1608 ve 1637 cm-1 dalga boylarındaki absorbsiyon miktarları kaydedildi. Her iki rezin siman türünden 10 örnek polimerizasyon öncesi ve sonrası FTIR analiziyle incelendi ve kontrol grubu olarak görev gördü. Elde edilen veriler yardımıyla rezin siman örneklerin dönüşüm dereceleri (%) hesaplandı. Veriler tek yönlü ANOVA, bağımsız t testi ve Tukey testleri ile analiz edildi (p<0.05). Her iki rezin siman türünde de en yüksek dönüşüm derecesi değerleri kontrol grubunda görülürken en düşük değerler 2 mm kalınlığındaki Vita Enamic kesiti altındaki örneklerde saptanmıştır (p<0.05). Tüm seramik kesitlerin 0.5 ve 1 mm kalınlıkları altında gerçekleştirilen polimerizasyon diğer kalınlıklara göre istatistiksel olarak daha yüksek değerler ortaya çıkmasını sağlamıştır (p<0.05). Aynı seramik kesitler altında polimerizasyonu gerçekleştirilen ışık ile polimerize olan rezin siman ve hem kimyasal hem de ışık ile polimerize olan rezin simanın dönüşüm dereceleri karşılaştırıldığında hem kimyasal hem de ışık ile polimerize olan rezin simanda daha yüksek değerler elde edilmiştir. Işık ile polimerize olan rezin simanın aynı kalınlıktaki seramik kesitlerin altındaki dönüşüm derecesi incelendiğinde 0.5 ve 1 mm kalınlığa sahip IPS Empress kesitler aynı kalınlıktaki diğer seramiklere göre istatistiksel olarak daha yüksek değerler ortaya koymuştur (p<0.05). Aynı kalınlıkların hem kimyasal hem de ışık ile polimerize olan rezin simanın dönüşüm derecesine olan etkileri incelendiğinde ise IPS Empress ile Vita Enamic arasında belirgin bir fark gözlemlenmiştir (p<0.05). 1.5 ve 2 mm kalınlığa sahip kesitlerde ise iki rezin siman türünde de seramikler arasında herhangi bir fark bulunmamıştır (p>0.05)Anahtar sözcükler: DönüĢüm derecesi; FTIR; rezin siman; tam seramik.
dc.description.abstractThe aim of this study was to evaluate the effect of different thicknesses of CAD / CAM ceramic sections on the polymerization of two different resin cements. Three CAD/CAM all-ceramic restorative materials (IPS Empress, Vita Enamic, Vita Suprinity) were sectioned using a low speed diamond saw with four different thicknesses (0.5, 1, 1.5, 2 mm). A total of 240 resin cement specimens were prepared from light cured and dual cure resin cements by means of polymerization under each ceramic section and were stored for 24 hours at 37 ° C. Absorbtion peaks were recorded at 1608 and 1637 cm-1 by testing with FTIR analysis to determine the degree of conversion of all samples. 10 samples of each resin cement type were examined by FTIR analysis before and after polymerization and served as the control group. Data were analyzed using one way ANOVA, independent t and Tukey HSD tests (p<0.05).For both resin cement types, the control group showed the highest degree of conversion values while samples cured under Vita Enamic section with a thickness of 2 mm presented the lowest values (p<0.05). Polymerization performed under 0.5 and 1 mm thicknesses of all ceramic sections provided statistically higher values than other thicknesses (p<0.05). Dual cure resin cement samples cured under the same ceramic sections showed higher degree of conversion values compared to light cured resin cement samples. When the degree of conversion of light cured resin cement samples cured under the same ceramic thicknesses were examined, IPS Empress sections with 0.5 and 1 mm thickness exhibited statistically higher values than other ceramics of the same thickness (p<0.05). When the effects of the same thicknesses on the degree of conversion of dual cure resin cement samples were examined, a significant difference between IPS Empress and Vita Enamic was observed (p<0.05). There was no difference for both resin cement types for sections of 1.5 and 2 mm (p>0.05).Key Words: All ceramic; degree of conversion; FTIR; resin cementen_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectDiş Hekimliğitr_TR
dc.subjectDentistryen_US
dc.titleFarklı kalınlıklardaki CAD/CAM seramiklerin rezin siman polimerizasyonuna olan etkisi
dc.title.alternativeThe effect of CAD/CAM ceramics of different thickness on resin cement polymerization
dc.typedoctoralThesis
dc.date.updated2019-08-22
dc.contributor.departmentProtetik Diş Tedavisi Anabilim Dalı
dc.subject.ytmFTIR
dc.subject.ytmComposite resins
dc.subject.ytmGlass ceramics
dc.subject.ytmCAD/CAM
dc.subject.ytmDental porcelain
dc.subject.ytmComposite resins
dc.subject.ytmAcrylic resins
dc.subject.ytmDental cements
dc.subject.ytmPolymerization
dc.subject.ytmInfrared spectroscopy
dc.identifier.yokid10215803
dc.publisher.instituteDiş Hekimliği Fakültesi
dc.publisher.universitySELÇUK ÜNİVERSİTESİ
dc.type.subdentistThesis
dc.identifier.thesisid538003
dc.description.pages115
dc.publisher.disciplineDiğer