Show simple item record

dc.contributor.advisorŞermatova, Saime
dc.contributor.authorAltaş, İbrahim Halil
dc.date.accessioned2020-12-04T15:48:06Z
dc.date.available2020-12-04T15:48:06Z
dc.date.submitted2009
dc.date.issued2018-08-06
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/91168
dc.description.abstractSon yıllarda kronik astım olgularında bronş duvarı kalınlaşması gibi yapısal değişikliklerin toraks yüksek rezolüsyonlu bilgisayarlı tomografi (YRBT) ile saptanabildiği bildirilmektedir.Bu olası değişiklikleri saptamak, astım şiddeti ile ilişkisini araştırmak, standart ve düşük doz YRBT bulgularını karşılaştırmak amacıyla 10. 10. 2008 - 01. 07. 2009 tarihleri arasında, akciğer radyogramında belirgin patoloji tespit edilmeyen, 30 stabil astımlı olguya hem standart doz (120kVp-180 mAs) hem de düşük doz (120kVp-60mAs ) toraks YRBT çekildi. Astımlı olguların 14 (% 46,7)'ü erkek, 16 (% 53,3)'si kadın olup, yaş ortalaması 40,06 ± 12.56 yıl idi. Hastalık süresi 6.46 ± 5.21 yıl idi.Astım şiddetine göre grup 1 (hafif intermitan,persistan) ve grup 2 (orta ve ağır persistan)'nin standart ve düşük doz toraks YRBT bulguları karşılatırıldı.Fibrotik değişikler açısından anlamlı fark saptandı (P<0,05).Standart doz ve düşük doz karşılaştırıldığında; duvar kalınlığı (T), duvar kalınlığı/dış çap oranı (T/D), bronş duvarı alanı (WA) ve bronş duvarı alanı yüzdesi (%WA) ölçümlerinde anlamlı bir fark izlenmedi(P>0,05). Sadece sağ akciğer lob bronşu T/D oranı yönünden anlamlı bir fark vardı (P<0,05).Her iki akciğer dokusunun ortalama HU (Hounsfield Unit) ve DE/Di değerleri yönünden karşılaştırıldığında anlamlı bir fark bulunmadı. Standart ve düşük dozda yapılan YRBT çekimlerde lezyon saptama hassasiyetinde istatiksel ve görüntü kalitesi yönünden anlamlı bir fark saptanmadı.(P>0,05)Yarar/zarar oranı karşılaştırıldığında; düşük doz YRBT çalışmalarında, hastanın aldığı radyasyon dozunun azalması ve YRBT cihazının tüp ömrünün uzamasından dolayı, düşük doz YRBT çalışmalarının tercih edilmesi giderek önem kazanmalıdır.Anahtar Kelimeler: Astım, standart doz yüksek rezolüsyonlu bilgisayarlı tomografi, düşük doz yüksek rezolüsyonlu bilgisayarlı tomografi, mAs, duvar kalınlaşması
dc.description.abstractHas informed that structural changes as bronch wall thickness can determine with torax high resolution computed tomography recent years. To determine this possible changes, to study relationship with asthma severity, with the aim of comparing standart and low dose HRCT findings, between 10 September 2008 and 1 July 2009, 30 stable cases with asthma that hasn?t promiment patology on lung radiogram, both standart dose (120 kVp 180 mAs) and low dose (120 kVp- 60 mAs) torax HRCT was taken at same time.. 14 (46,7%) of asthma cases were man, 16 (53,3%) of asthma cases were women and mean age was 40,06 ± 12,56 years. Duration of disease was 6,46±5,21 years.Standart and lowe dose in group 1 (slight intermittent, persistent) and group 2 (mean and heavy persistent) torax HRCT findings were compared according to asthma severity. Fibrotic variables from the angle expressive was determine.(P<0,05)When standart and low dose were compared; wall thickness (T), wall thickness/outer diameter (T/D), bronch wall area (WA), bronch wall area % (%WA) measurements from the angle expressive one difference wasn?t determined .(P>0,05). Only Right lung bronch wall thickness (WA)/outer diamater (D) ratio from the angle expressive one diference was determined (P<0,05).Both lung tissues mean HU (Hounsifield unit) and DE/Dİ rates there wasn?t determined for image quality or statistical significant difference in standart and lowe dose tomography in lesion sensitivite, because in P was > 0,05.When Benefit/harm ratio were compared; in low-dose HRCT studies, the reduction of radiation dose the patient receives and HRCT tools tube due to prolongation of life, low-dose HRCT studies should be preferred gaining importance.Keywords: Asthma, standart dose high resolution computed tomography, lowe dose high resolution computed tomography, mAs, wall thicknessen_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectRadyoloji ve Nükleer Tıptr_TR
dc.subjectRadiology and Nuclear Medicineen_US
dc.titleAstımlı hastalarda standart doz YRBT ile düşük doz YRBT bulgularının karşılaştırılması
dc.title.alternativeComparison findings of standard dose and low dose HRCT on patients with asthma
dc.typedoctoralThesis
dc.date.updated2018-08-06
dc.contributor.departmentRadyoloji Anabilim Dalı
dc.identifier.yokid360442
dc.publisher.instituteTıp Fakültesi
dc.publisher.universityHARRAN ÜNİVERSİTESİ
dc.type.submedicineThesis
dc.identifier.thesisid247931
dc.description.pages92
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess