Show simple item record

dc.contributor.advisorIşımer, Aşkın
dc.contributor.authorAlakabak, Cemal
dc.date.accessioned2023-09-26T12:04:32Z
dc.date.available2023-09-26T12:04:32Z
dc.date.submitted2021-09-30
dc.date.issued1993
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/757683
dc.description.abstractÖZET Atomik absorpsiyon spektrofotometrEsinin 5 ayrı yöntemi olan klasik alevli atomik absorpsiyon spektrof otometrisi, klasik alev li atomik absorpsiyon +- atom yakalama yöntemi, klasik alevli atomik absorpsiyon + metil izobutil keton ekstraksiyonu yöntemi, klasik alevli atomik absorpsiyon +. metil izobutil keton ekstrak siyonu + atom yakalama yöntemi ve grafit farınla atomik absorpsi yon yöntemleri birbirleriyle karşılaştırıldı. Karşılaştırma parametreleri olarak optimum çalışma aralığı, tayin limiti, duyarlılık, geri elde etme ve varyasyon katsayısı sonuçları değerlendirildi. Bu parametrelere göre kla sik alevli atomik absorpsiyon + metil izobutil keton + atom yaka lama yönteminin kurşun ölçümlerinde kullanılabilecek en uygun yöntem olabileceği değerlendirildi; kronik olarak eksoz gazına maruz kalan grupla kontrol gruplarının kan ve idrar kurşun ölçümleri de bu yönteme göre yapıldı. Maruz grubun idrar kurşun seviyeleri kontrol grubundan anlamlı şekilde yüksek bulundu (p<0.05), kan kurşun sonuçları arasında ise anlamlı anlamlı bir fark tespit edilmedi. - 78 -
dc.description.abstractSUMMARY THE INVESTIGATION OF LEAD LEVELS WITH DIFFERENT ATOMIC ABSORPTION SPECTROPHOTOMETRY TECNIQUES Five different techniques consisting of classical flame atomic absorption spectrophotometry, flame atomic absorption spectrophotometry combined with atom trapping technique, flame atomic absorption spectrophotometry combined with methyl isobuthyl ketone extraction technique, flame atomic absorption spectrophotometry combined with methyl isobuthyl ketone extraction and atom trapping technique, graphite furnace atomic absorption spactrophotometry were compared with each other. Optimum working range, detection limit, sensitivity, recovery and variation coefficients were used as compairing parameters and they were evaluated. According to these parameters, it was con sidered that flame atomic absorption spectrophotometry combined with methyl isobuthyl ketone extraction and atom trapping technique can be the best appropriate technique to determine lead levels; lead levels in urine and blood samples of control and chronically exposed to exhaused gases groups were determined with this technique- Urine lead levels of exposed group were found significantly higher than control group(p<0.05), signifi cant difference was not found between blood lead levels. - 79 -en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/embargoedAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectEczacılık ve Farmakolojitr_TR
dc.subjectPharmacy and Pharmacologyen_US
dc.titleDeğişik atomik absorpsiyon spektrofotometri yöntemleriyle kurşun düzeylerinin araştırılması
dc.title.alternativeThe Investigation of lead levels with different atomic absorption spectrophotometry tecniques
dc.typemasterThesis
dc.date.updated2021-09-30
dc.contributor.departmentFarmasötik Toksikoloji Ana Bilim Dalı
dc.subject.ytmUrine
dc.subject.ytmBlood
dc.subject.ytmLead
dc.subject.ytmLead poisoning
dc.subject.ytmSpectrophotometry-atomic
dc.subject.ytmToxicology
dc.identifier.yokid31599
dc.publisher.instituteSağlık Bilimleri Enstitüsü
dc.publisher.universityGÜLHANE ASKERİ TIP AKADEMİSİ
dc.identifier.thesisid31599
dc.description.pages94
dc.publisher.disciplineDiğer


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/embargoedAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/embargoedAccess