Show simple item record

dc.contributor.advisorKarakaş, Prof.Dr.Eyüp Selahattin
dc.contributor.authorSaylık, Murat
dc.date.accessioned2023-09-26T11:36:43Z
dc.date.available2023-09-26T11:36:43Z
dc.date.submitted2019-11-12
dc.date.issued2002
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/752763
dc.description.abstractSağlık Bakanlığı Taksim Eğitim ve Araştırma Hastanesinde 1999 ve 2001 yılları arasında,intra kapsüler kollum femoris fraktürü olan 21 hastanın 21 kalçasına bipolar kalça hemiartroplastisi uygulandı.2 hasta postoperatif erken dönem ex , 3 hasta takipten çıktığından çalışma dışı bırakıldı.Hastaların yaş ortalaması kadınlarda;67(minimum;38- maximum;79) ve erkeklerde; 66(minimum;48-maximum;89) olarak bulundu.En genç 38 en yaşlı 89 ,Ortalama yaş;66.6 .Takip süresi 16(minimum;6- maximum;27)ay.Harris kalça skoru ;8 hasta(%50 ) mükemmel sonuç, 4 hasta (%25) iyi sonuç,1 hasta(%6.25) orta sonuç,3 hasta(%18.75) kötü sonuç olarak değerlendirildi.Kwok kriterlerine göre yapılan bir değerlendirmede ;11 hasta iyi,3 hasta orta, 2 hasta kötü olarak değerlendirildi.Radyolojik olarak protezin iç dış hareketi ölçüldü. protez iç ve dış hareket ölçümünde İç hareket 12(minimum;5- maximum;25) derece,dış Hareket 4(minimum ;0-maximum;11) derece olarak ölçüldü.İç dış hareket oranı;3 olarak görüldü.Bipolar hemiartroplasti uygulaması sonrası iç hareket dış hareketten daha fazla olduğundan, asetabuler erozyonu önleyici etkisi olduğu sonucuna ulaşıldı.
dc.description.abstractBetween 1999 and 2001 at the Ministry of Health Taksim Training and Research Hospital, 21-year-old 21 hip hips with hemiarthroplasty were applied to 21 hips with collum femoris fracture. minimum; 38- maximum; 79) and males; 66 (minimum; 48-maximum; 89). The youngest 38 oldest 89, the average age; 4 patients (25%) had good outcome, 1 patient (6.25%) had moderate outcome and 3 patients (18.75%) had poor outcome.In an evaluation made according to Kwok criteria; 11 patients were evaluated as good, 3 patients as moderate and 2 patients as poor. Internal and external level of the prosthesis was measured radiologically. internal and external movement measurement of the prosthesis was measured as 12 (minimum; maximum 5-5; 25) degrees, and external movement as 4 (minimum; 0-maximum; 11) degrees. 3.It was concluded that there was a greater number of acetabular erosion preventive effects than bipolar hemiarthroplasty.en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectOrtopedi ve Travmatolojitr_TR
dc.subjectOrthopedics and Traumatologyen_US
dc.titleBipolar protez uygulamaları ve sonuçları
dc.title.alternativeBipolar prosthesis applications and results
dc.typedoctoralThesis
dc.date.updated2019-11-12
dc.contributor.departmentDiğer
dc.identifier.yokid10307747
dc.publisher.instituteTaksim Eğitim ve Araştırma Hastanesi
dc.publisher.universityDİĞER (KURUMLAR, HASTANELER VB.)
dc.type.submedicineThesis
dc.identifier.thesisid576438
dc.description.pages90
dc.publisher.disciplineDiğer


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess