Show simple item record

dc.contributor.advisorDivrikli, Ümit
dc.contributor.authorSevinç, Berivan
dc.date.accessioned2023-09-22T12:35:22Z
dc.date.available2023-09-22T12:35:22Z
dc.date.submitted2023-04-05
dc.date.issued2023
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/741800
dc.description.abstractBu tezde, krom(III) tayini için, Aloe vera ile modifiye edilmiş Fe3O4 nano biyokompozit kullanılarak, manyetik katı faz ekstraksiyonu ile (Aloe vera-nZVI-MSPE) yöntem geliştirilmesi ve atomik absorpsiyon spektrometresiyle tayini amaçlanmıştır. Aloe vera-nZVI nano biyokompozitin yapısal karekterizasyonu Fourier Dönüşümlü Kızılötesi Spektroskopisi (ATR-IR), Enerji Dağılımlı X-ışını sepektroskopisi (EDS) ve Taramalı Elektron Mikroskobu (SEM) ile incelenmiştir. Krom(III) iyonu alıkonması, 50 mg Aloe vera-nZVI nano biyokompozitiyle, pH 7'de 200 mL'lik örnekten, 1 mL 1 mol/L HNO3 elüentiyle ≥ %95 kantitatif geri kazanımla elde edilmiştir. Ekstraksiyon süresi 10 dk olarak belirlenmiştir. Zenginleştirme faktörü 200 mL örnek hacmi ve 1 mL elüent hacmiyle 200 olarak hesaplandı. Optimum şartlarda, gözlenebilme sınırı 3,4 µg/L, tayin sınırı 8,9 µg/L, yöntemin bağıl hatası %5,5 olarak bulunmuştur. Sertifikalı referans su örneklerinin analizi ve standart ekleme deneyleri ile doğrulanmıştır ve yöntemin doğrululuğu test edilmiştir. Yöntem çeşitli su örneklerindeki krom(III) tayinine başarıyla uygulanmıştır.
dc.description.abstractIn this thesis, for the determination of chromium(III) method components by magnetic solid phase extraction (Aloe vera-nZVI-MSPE) using Aloe vera modified Fe3O4 nano biocomposite and its determination by atomic absorption spectrometry predictions. Structural characterization of aloe vera-nZVI nano biocomposite was investigated by Fourier Transform Infrared Spectroscopy (ATR-IR), Energy Dispersive X-ray spectroscopy (EDS), and Scanning Electron Microscopy (SEM). Chromium(III) ion retention was obtained with 50 mg Aloe vera-nZVI from 200 mL sample at pH 7 with ≥% 95 quantitative recovery with 1 mL of 1 mol/L HNO3 eluent. The extraction time was set as 10 min. The enrichment factor was calculated as 200 with a sample volume of 200 mL and an eluent volume of 1 mL. Under optimum conditions, the detection limit was 3.4 µg/L, the detection limit was 8.9 µg/L, and the relative error of the method was %5. It has been verified by analysis of certified reference water samples and standard addition experiments, and the accuracy of the method has been tested. The method has been successfully applied to the determination of chromium (III) in various water samples.en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectKimyatr_TR
dc.subjectChemistryen_US
dc.titleManyetik aloe vera biyokompoziti ile krom tayini
dc.title.alternativeDetermination of chromium by magnetic aloe vera biocomposite
dc.typemasterThesis
dc.date.updated2023-04-05
dc.contributor.departmentKimya Ana Bilim Dalı
dc.identifier.yokid10320722
dc.publisher.instituteFen Bilimleri Enstitüsü
dc.publisher.universityPAMUKKALE ÜNİVERSİTESİ
dc.identifier.thesisid784251
dc.description.pages81
dc.publisher.disciplineDiğer


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess