dc.description.abstract | Amaç: Bu çalışmasının amacı ortodontik mini-vidaların stabilitesinde kemik simanlarının etkisini in-vitro olarak incelemektir.Materyal ve Metot: Çalışmamızda iki farklı mini-vida, Dewimed ve Sydney, kullanıldı. Mini-vidalar ile koyun humerus kemiğinin `proksimal metafizi` bölgesinde yerleştirildi. 30 Dewimed mini-vida ve 30 Sydney mini-vida rehber oluklar açılarak kemiğe yerleştirildi. 30 Dewimed mini-vida vidalama öncesi rehber oluklar açılarak ve rehber oluklara kemik simanı konularak kemiğe yerleştirildi. 30 Sidney mini-vida rehber oluklar hazırlandıktan kemik bloğa yerleştirilmiştir ve sonrasında kemik simanı vidanın kanülüne enjekte edildi. Her bir grup, mini-vidaların stabilitesini değerlendirmek amacıyla, iki eşit alt gruba ayrılarak, çıkarma tork değerleri ve pull-out değerleri ölçüldü.Bulgular: Her iki mini-vidanın siman uygulanmış ve uygulanmamış çıkarma tork ve pull-out değerleri kendi içlerinde karşılaştırıldığında istatistiksel olarak önemli fark bulunmadı (P>0,0083). Dewimed mini-vidanın siman uygulanmış ve uygulanmamış tork değerlerinin Sydney mini-vidanın siman uygulanmış ve uygulanmamış tork değerlerinden istatistiksel olarak daha büyük olduğu izlendi (P<0,0083). Sydney mini-vidanın siman uygulanmış ve uygulanmamış pull-out değerlerinin Dewimed mini-vidanın siman uygulanmış ve uygulanmamış pull-out değerlerinden istatistiksel olarak daha büyük olduğu izlendi (P<0,0016).Sonuç: Bu çalışmanın bulguları ışığında, kemik simanlarının mini-vida stabilitesi üzerinde etkisi olmadığı sonucuna ulaşabiliriz.Anahtar Kelimeler: Çıkarma torku; kemik simanı; mini-vida; pull-out; stabilite. | |
dc.description.abstract | Aim: The purpose of this study was the in-vitro evaluation of the effect of bone cement on the stability of mini-screws.Material and Methods: Two different mini-screws, Dewimed and Sydney, were used in this study. Mini-screws were inserted into the `proximal metaphysis` of sheep humerus bone. Thirty Dewimed and 30 Sydney mini-screws were inserted into the bone after pre-drilling without any cement application. Thirty Dewimed mini-screws were inserted into the pre-drilling hole which had been filled with cement. Thirty Sydney mini-screws were inserted after pre-drilling and subsequently bone cement was injected into the cannula of the mini-screw extending from the head to the lateral port holes. Each group was divided into two subgroups to measure the removal torque and the pull-out values for the evaluation of mini-screw stability.Results: Application and non-application of bone cement did not show any significant difference for both mini-screw types (P>0.0083). Removal torque values of Dewimed mini-screws, application and non-application of cement, were significantly higher than that of the Sydney mini-screws (P>0.0083). Pull-out values of Sydney mini-screws, application and non-application of cement, were significantly higher than that of the Dewimed mini-screws (P>0.0016).Conclusion: According to the results of this study it can be concluded that the application of bone cement did not affect the stability of mini-screws.Key Words: Bone cement;mini-screw; pull-out; removal torque; stability. | en_US |
dc.language | Turkish | |
dc.language.iso | tr | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Attribution 4.0 United States | tr_TR |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject | Diş Hekimliği | tr_TR |
dc.subject | Dentistry | en_US |
dc.title | Kemik simanlarının mini-vida stabilitesi üzerine etkisi: İn vitro çalışma | |
dc.title.alternative | Effects of bone cement on the stability of miniscrews: In-vitro study | |
dc.type | doctoralThesis | |
dc.date.updated | 2019-03-16 | |
dc.contributor.department | Ortodonti Ana Bilim Dalı | |
dc.subject.ytm | Dental cements | |
dc.subject.ytm | Orthodontics | |
dc.subject.ytm | Bone screws | |
dc.subject.ytm | Dental bonding | |
dc.subject.ytm | In vitro | |
dc.identifier.yokid | 10105107 | |
dc.publisher.institute | Sağlık Bilimleri Enstitüsü | |
dc.publisher.university | ONDOKUZ MAYIS ÜNİVERSİTESİ | |
dc.identifier.thesisid | 424853 | |
dc.description.pages | 66 | |
dc.publisher.discipline | Diğer |