Farklı renklerdeki feldspatik seramiklerin farklı ışık kaynakları kullanılarak rezin simanla olan bağlantısının değerlendirilmesi
dc.contributor.advisor | Duran, İbrahim | |
dc.contributor.author | Yilmaz Evmek, Betül | |
dc.date.accessioned | 2021-05-08T10:59:45Z | |
dc.date.available | 2021-05-08T10:59:45Z | |
dc.date.submitted | 2016 | |
dc.date.issued | 2020-01-03 | |
dc.identifier.uri | https://acikbilim.yok.gov.tr/handle/20.500.12812/677917 | |
dc.description.abstract | Amaç : Bu çalışmanın amacı farklı renklerdeki CAD-CAM üretim tekniğinde kullanılan prefabrike feldspatik seramik blokların, farklı ışık kaynakları altında rezin simanla olan bağlantısının değerlendirilmesidir.Materyal ve Metot : Çalışmada 2mm (±0.1 mm) kalınlıkta ve 9 farklı renk grubunda Cerec feldspatik seramik örnekler hazırlandı. Bütün örnekler Plazma ark (2400 mw/cm2), LED (1600-1800 mw/cm2) ve halojen (800-1200 mw/cm2) ışık kaynakları kullanılarak ışıkla sertleşen rezin simanla kompozit rezin bloklara bağlandı. Simantasyondan sonra kapalı kaplarda distile su içerisinde 24 saat bekletilen örneklere makaslama testi uygulandı. Elde edilen sonuçlar istatistiksel olarak iki yönlü varyans analizi (ANOVA), tek yönlü varyans analizi (ANOVA), ve Tukey HSD testi kullanılarak değerlendirildi (p<0,05).Bulgular : Çalışmanın sonuçları istatistiksel olarak değerlendirildiğinde, gruplar içerisinde plazma ark grubu en yüksek ortalama değere sahipken, en düşük değer halojen grubundadır ve aralarında istatistiksel olarak anlamlı farklılık vardır (p<0,05). Işık cihazı ayırt edilmeksizin en yüksek bağlantı dirençleri S2M ve S2T renk gruplarında elde edilmiş ve bu gruplar arasında istatistiksel olarak anlamlı bir farklılık bulunamamıştır. En düşük bağlantı direnci ise S4O renk grubunda elde edilmiştir.Sonuç : Yapılan bu in vitro çalışmanın sonucunda feldspatik seramik restorasyonların bağlantı direncinin kullanılan ışık kaynağı ile doğrudan ilişkili olduğu ortaya çıkmış ve seramik rengi koyulaştıkça bağlantı direnci düşmüştür. Çıkan sonuçlar ışığında, 2mm kalınlığındaki koyu renkli restorasyonlarda ışıkla polimerize olan rezin siman sisteminin yerine dual olarak polimerize olan rezin sisteminin kullanımının daha güvenli olabileceği söylenebilir.Anahtar Kelimeler : Bağlantı dayanımı, CAD-CAM, Işık cihazları, Rezin siman | |
dc.description.abstract | Aim : The aim of this study is to investigate the bonding with resin cement different prefabricated feldspathic ceramic blocks in different colors used in CAD-CAM manufacturing technique with different light sources beneath ceramics.Material and Method : In this study, feldspathic ceramic speciments were prepared 2mm thickness in nine different colors. All groups were bonded to composite resin blocks with a light-cure resin cement beneath plasma arc (2400 mW/cm2), LED (1600-1800 mW/cm2) and halogen (800-1200 mW/cm2) light sources. After the cementation, all speciments were kept in distilled water for 24 hours in closed cups and shear test was performed. The data were analyzed with two-way and one-way analysis of variance (ANOVA) and Tukey HSD test (p<0,05).Results : When the results of the study are evaluated statistically, for all groups while the highest light power was observed in plasma arc groups, the lowest was observed in halogen groups and difference was statistically significant (p<0,05). The highest bonding strength were obtained in the S2M and S2T color groups without discrimination of the light source, and no statistically significant difference was found between these groups. The lowest bonding strength is obtained in the S4O color group.Conclusion : As a result of this in vitro study, it has been found that the feldspathic ceramic restorations are directly related to the light source of the bonding strength and the bonding strength decreases as the ceramic color becomes darker. In the light of the results, it can be said that the use of dual polymerized resin system may be safer instead of the light-cured resin system which is polymerized by light in dark restorations of 2mm thickness.Keywords : Bond strength, CAD-CAM, Light curing units, Resin cement | en_US |
dc.language | Turkish | |
dc.language.iso | tr | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Attribution 4.0 United States | tr_TR |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject | Diş Hekimliği | tr_TR |
dc.subject | Dentistry | en_US |
dc.title | Farklı renklerdeki feldspatik seramiklerin farklı ışık kaynakları kullanılarak rezin simanla olan bağlantısının değerlendirilmesi | |
dc.title.alternative | The evaluation of resin bond strength of feldspathic ceramics in different colors using different light source | |
dc.type | doctoralThesis | |
dc.date.updated | 2020-01-03 | |
dc.contributor.department | Protetik Diş Tedavisi Ana Bilim Dalı | |
dc.subject.ytm | Dental bonding | |
dc.subject.ytm | Dental cements | |
dc.subject.ytm | Dental materials | |
dc.subject.ytm | Dental porcelain | |
dc.subject.ytm | Dental stress analysis | |
dc.subject.ytm | CAD/CAM | |
dc.subject.ytm | Resin | |
dc.subject.ytm | Resins-synthetic | |
dc.identifier.yokid | 10133860 | |
dc.publisher.institute | Sağlık Bilimleri Enstitüsü | |
dc.publisher.university | ONDOKUZ MAYIS ÜNİVERSİTESİ | |
dc.identifier.thesisid | 454098 | |
dc.description.pages | 104 | |
dc.publisher.discipline | Diğer |