Show simple item record

dc.contributor.advisorÖzbek Okumuş, Nilgün
dc.contributor.authorDöner, Fatih Mehmet
dc.date.accessioned2021-05-08T10:58:53Z
dc.date.available2021-05-08T10:58:53Z
dc.date.submitted2018
dc.date.issued2019-05-09
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/677715
dc.description.abstractAmaç: Çalışmamızda, vertebra metastazlarında planlama tekniklerinin medulla spinalisin maksimum doz değerine (D-maks), homojenite (HI) ve konformalite indeksine (CI) etkisi araştırıldı.Materyal ve Metot: Bu çalışmada Ondokuz Mayıs Üniversitesi Radyasyon Onkolojisi Anabilim Dalı'nda vertebra metastazı nedeni ile tedavi edilen 20 hastanın 3 mm kesitlerle çekilen bilgisayarlı tomografi görüntüleri kullanıldı. Metastatik vertebranın bir üst ve altındaki vertebrayı içerecek şekilde klinik hedef hacim (CTV) oluşturuldu. CTV'ye her yönden 5 mm marjin verilerek planlanan hedef hacim (PTV) belirlendi. Her bir hasta için 3-boyutlu konformal radyoterapi (3D-CRT), alan-içinde-alan yoğunluk ayarlı radyoterapi (for-IMRT), IMRT ve hacimsel yoğunluk ayarlı ark tedavisi (VMAT) planlamaları yapıldı. PTV'ye doz, fraksiyon başına 3 Gray (Gy)'den toplam 30 Gy olarak tanımlandı. Elde edilen tüm verilerin istatistiksel analizinde SPSS 24.0 programı kullanıldı. Bulgular: Ortanca D-maks değerleri VMAT ve IMRT'de 3D-CRT ile for-IMRT'den istatistiksel olarak anlamlı düzeyde (p=0.000) daha düşüktü. Ortanca HI değerlerinin, VMAT ve IMRT tekniklerinde karşılaştırılmasında istatistiksel anlamlı fark saptanmazken (p>0.05), her iki tekniğin hem for-IMRT hem de 3D-CRT'den istatistiksel olarak anlamlı düzeyde (p=0.000) daha düşük HI değerlerine sahip olduğu belirlendi. Ortalama CI değerlerine göre tüm planlama teknikleri arasında istatistiksel anlamlı fark (p≤0.001) saptandı. En konformal planlama, VMAT tekniği ile elde edildi. Sonuç: IMRT veya VMAT tekniği ile vertebra metastazlarının tedavisinde daha iyi CI ve HI değerleri ile en düşük doz maksimum değeri elde edilerek tedavi planlaması yapılmaktadır. Anahtar Kelimeler: Vertebra; Medulla spinalis; 3D-CRT; IMRT; VMAT
dc.description.abstractAim: In our study, the effect of planning techniques on vertebral metastases on maximal dose of medulla spinalis (D-max), homogeneity (HI) and conformity index (CI) was investigated.Material and Method: In this study, 20 patients treated with the reason of vertebrae metastases in Ondokuz Mayıs University Radiation Oncology Department, computerized tomography images taken with 3 mm cross section were used. The clinical target volume (CTV) was defined as the metastatic vertebrae with an upper and a lower vertebrae. The planned target volume (PTV) was created by giving a margin of 5 mm on each side of the CTV. Three-dimensional conformal radiotherapy (3D-CRT), field-in-field intensity modulated radiotherapy (for-IMRT), IMRT and volumetric modulated arc therapy (VMAT) planning were performed for each patient. The PTV dose was defined as a total of 30 Gy per 3 Gray (Gy) per fraction. Statistical analysis of all data was performed with the SPSS 24.0 program.Results: Median D-max values were statistically significantly lower (p = 0.000) than 3D-CRT and for-IMRT in VMAT and IMRT. There was no statistically significant difference between the median HI values in VMAT and IMRT techniques (p> 0.05) and both techniques had lower HI values statistically significant (p = 0.000) than both for-IMRT and 3D-CRT. A statistically significant difference (p≤0.001) was found between all planning techniques according to the mean CI values. The most conformal planning was achieved with the VMAT technique.Conclusion: In planning for vertebra metastases, planning with IMRT or VMAT technique is recommended to provide better CI and HI values and the lowest dose maximum.Keywords: Vertebra; Medulla spinalis; 3D-CRT; IMRT; VMATen_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectNükleer Mühendisliktr_TR
dc.subjectNuclear Engineeringen_US
dc.subjectOnkolojitr_TR
dc.subjectOncologyen_US
dc.titleVertebra metastazlarında farklı planlama teknikleri ile medulla spinalisin maksimum doz değerinin karşılaştırılması
dc.title.alternativeComparison of maximum dose value of medulla spinal with different planning techniques in vertebra metastases
dc.typemasterThesis
dc.date.updated2019-05-09
dc.contributor.departmentRadyolojik Bilimler Ana Bilim Dalı
dc.subject.ytmSpinal cord neoplasms
dc.subject.ytmSpinal neoplasms
dc.subject.ytmNeoplasm metastasis
dc.subject.ytmNeoplasms
dc.subject.ytmRadiotherapy-intensity-modulated
dc.subject.ytmRadiotherapy-computer assisted
dc.subject.ytmRadiotherapy
dc.identifier.yokid10215556
dc.publisher.instituteSağlık Bilimleri Enstitüsü
dc.publisher.universityONDOKUZ MAYIS ÜNİVERSİTESİ
dc.identifier.thesisid519495
dc.description.pages67
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess