dc.description.abstractAmaç: Bu çalışma Cavalieri Prensibine dayanarak organ hacim ölçümünde kullanılan bilgisayar ara yüzlerinin (bilgisayar faresi ve grafik tablet) avantaj ve dezavantajlarını tutarlılık, süre ve konfor kriterlerine göre kıyaslayarak kullanılan teçhizatın güvenirliklerini belirlemeyi amaçlamaktadır.Materyal ve metot: Çalışmamızda Ondokuz Mayıs Üniversitesi Radyoloji Anabilim dalına ait radyolojik görüntüleme merkezinden alınan, 22 kadın ve 21 erkeğe abdominal bilgisayarlı tomografi (BT) görüntüleri kullanıldı. ImageJ yazılımı ile Cavalieri Prensibine uygun olarak BT görüntüleri üzerinden dalak ve böbrek hacimleri hesaplandı. Hesaplama sırasında bilgisayar faresi ve grafik tablet kullanıldı. Bulgular: Bilgisayar faresi kullanılarak alınan böbreğe ait hacim ölçümlerinin ortalaması 181,53 ±51,72 cm3 olarak tespit edildi. Aynı cihaz ile yapılan dalağa ait ölçümlerde dalak hacim ortalaması 211,03 ±78,47 cm3 olarak ölçüldü. Bilgisayar faresi kullanılarak böbrek ve dalak üzerinden alınan hacim ölçümleri sırasında tutulan süre ortalamaları sırası ile 283,55 ±56,03 sn ve 386,74 ±106,66 sn olarak tespit edildi. Grafik tablet kullanılarak alınan böbreğe ait hacim ölçümlerinin ortalaması 179,34 ±51,37 cm3 olarak tespit edildi. Aynı cihaz ile yapılan dalağa ait ölçümlerde dalak hacmi 205,93 ±77,52 cm3 olarak ölçüldü. Grafik tablet kullanılarak böbrek ve dalak üzerinden alınan ölçümler sırasında tutulan süre ortalamaları sırası ile 128,79 ±33,32 sn ve 141,91 ±40,18 sn olarak tespit edildi. İki cihaza ait hacim sonuçları arasında istatiksel olarak anlamlı fark bulundu (p<0,001). Süre bazında grafik tabletin daha hızlı ölçüm almaya olanak sağladığı istatiksel olarak tespit edildi (p<0,001). Sonuç: Çalışmada elde ettiğimiz verilere dayanarak, grafik tabletlerin Cavalieri Prensibinin uygulanması sırasında bilgisayar faresine alternatif kullanılabilecek bir cihaz olduğunu ortaya konulmuştur.
dc.description.abstractAim: This study aims to determine the reliability of the used equipment comparing the advantages and disadvantages of the computer interfaces (computer mouse and graphic tablet) used in organ volume measurements based on Cavalieri Principle by consistency, duration and comfort criteria.Material and Method: 22 female and 21 male abdominal computarized tomography (CT) images obtained from The Radiological Imaging Center of Ondokuz Mayis University, Department of Radiology were used in this study. Sleen and kidney volumes were measured on CT images by Image J software according to Cavalieri Principle. Computer mouse and graphic tablet were used during measurement.Results: The mean measurements of kidney volume taken by computer mouse was found as 181.53 ± 51.72 cm3. The mean volume of the spleen measured by the same device, was 211.03 ± 78.47 cm3. The mean duration of the volume measurements taken from the kidney and spleen by using the computer mouse was 283.55 ± 56.03 sec and 386.74 ± 106.66 sec, respectively. The mean volume measurements of kidney taken by using graphic tablet were found as 179.34 ± 51.37 cm3. The mean volume of the spleen performed by the same device, was measured as 205.93 ± 77.52 cm3. The mean durations calculated during the measurements of the kidney and spleen by using the graphic tablet were 128.79 ± 33.32 sec and 141.91± 40.18 sec, respectively. A statistically significant difference was found between the volume results of the two devices (p <0.001). It was identified that the graphical tablet allows for faster measurement (p <0.001).Conclusion: Based on the data obtained in the study, it was revealed that the graphics tablets were an alternative to the computer mouse during the application of the Cavalieri Principle.en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectAnatomitr_TR
dc.subjectAnatomyen_US
dc.titleCavalieri prensibi ile izole organ hacimlerinin planimetri ve grafik tablet kullanarak hesaplanmasının etkinliğinin karşılaştırılması
dc.title.alternativeComparison of effectiveness of the calculation of isolated organ volumes with cavalieri principle by using planimetry and graphical tablets
dc.typedoctoralThesis
dc.date.updated2020-01-23
dc.contributor.departmentAnatomi Ana Bilim Dalı
dc.subject.ytmCavalieri principle
dc.subject.ytmOrgan
dc.subject.ytmOrgan weight
dc.subject.ytmKidney
dc.subject.ytmVolume
dc.subject.ytmVolumetric analysis
dc.subject.ytmGraphic tablet
dc.subject.ytmStereology
dc.identifier.yokid10239302
dc.publisher.instituteSağlık Bilimleri Enstitüsü
dc.publisher.universityONDOKUZ MAYIS ÜNİVERSİTESİ
dc.identifier.thesisid548980
dc.description.pages66
dc.publisher.disciplineDiğer