Show simple item record

dc.contributor.advisorEkici, Behice
dc.contributor.authorÇetin, Kenan
dc.date.accessioned2021-05-08T09:05:39Z
dc.date.available2021-05-08T09:05:39Z
dc.date.submitted2019
dc.date.issued2020-04-22
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/662631
dc.description.abstractAraştırma, Yenidoğan Yoğun Bakım (YYB) ünitesinde tedavi gören term ve pretermlerde kullanılan kuvöz örtüsünün yenidoğanların vital bulgularına etkisini belirlemek amacı ile gerçekleştirildi. Araştırmanın örneklemini Siverek Devlet Hastanesi YYB ünitesinde Kasım 2017- Mart 2018 tarihleri arasında yatan, araştırma kriterlerine uyan ve ailelerinden gönüllü onam izni alınan 91 yenidoğan oluşturdu. Veriler, Yenidoğan Tanıtıcı Bilgi ve Uygulama Formu, cilt ısı probu, pulse oksimetre, kuvöz, kuvöz örtüsü, mezura, ses desibeli ölçüm cihazı kullanılarak toplandı. Veriler; sayı, yüzde, ortalama, ortanca, Fisher, Mann Whitney U, T, ki-kare ve Friedman testleri ile analiz edilmiştir. İstatiksel anlamlılık değeri p<0,05 kabul edilmiştir. Yenidoğanların %57,1'in erkek, gestasyon yaş ortancası 37.0'dır. Term ve preterm yenidoğanlarda örtülü - örtüsüz gruplarda nabız ve solunum sayısı ortanca değerleri arasında anlamlı farklılık saptanmamıştır (p>0,05). Termlerin ve pretermlerin oksijen satürasyon düzeyi kuvöz örtülü grupta 99.0-100.0 aralığında; örtüsüz gruptaki termlerin 99.0-99.5; pretermlerin 99.0-100.0 aralığında olduğu ve istatistiksel olarak farkın anlamlı (p<0,001) olduğu belirlendi. Term ve pretermlerde, kuvöz örtülü olanlarda 30. dakikadaki vücut sıcaklığı ortancası 0. ve 15. dakikalardaki ortanca değerlerine göre yüksek olduğu (p=0,034) ve istatistiksel olarak farkın anlamlı olduğu belirlendi (p<0,05). Sonuç olarak; kuvöz örtüsünün term ve pretermlerin vital bulgularına etkisinin çoklu YYB ünitelerinde incelenmesi, bu araştırmada kullanılan kuvöz örtüsü ile diğer kuvöz örtülerinin etkinliğini araştıran başka çalışmalar önerilir
dc.description.abstractThe study examined the effects of the incubator covers used in the treatment of full term and preterm newborns in Neonatal Intensive Care Units (NICUs) on their vital signs. The study sample included 91 newborns in the NICUs of Siverek Public Hospital between November 2017 and March 2018, who met the inclusion criteria and whose parents signed the voluntary informed consent form. The data were collected using a Newborn Introductory Information and Administration Form, a skin temperature probe, a pulse oximeter, an incubator, an incubator cover, a tape measure and an audio level meter, and analyzed using frequencies, percentages, means, medians, and the Fisher, Mann-Whitney U, t, chi-square and Friedman tests. The threshold for statistical significance was p<0.05. of the newborns, 57.1% were male, and the median gestation age was 37.0. There were no statistically significant differences between the median values of the pulse rate and the respiratory rate of the covered and uncovered groups of full term and preterm newborns (p>0.05). The oxygen saturation levels of the covered full term and preterm newborns, the uncovered full term newborns and the uncovered preterm newborns varied between 99.0-100.0, 99.0-99.5 and 99.0-100.0, respectively, and the differences between them were statistically significant (p<0.001). The covered full term and preterm newborns' body temperature medians were higher at the 30th minute than at the 0 and 15th minutes (p=0.034), and the differences between them were statistically significant (p<0.05). As a result, studies should examine the effect of incubator covers on the vital signs of full term and preterm newborns in multiple NICUs, and the effectiveness of the incubator cover used in this study and other incubator covers should be evaluated.en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectHemşireliktr_TR
dc.subjectNursingen_US
dc.titleKuvöz örtüsünün term ve preterm yenidoğanların vital bulgularına etkisi
dc.title.alternativeThe effect of an incubator cover on full term and preterm newborns' vital signs
dc.typemasterThesis
dc.date.updated2020-04-22
dc.contributor.departmentHemşirelik Ana Bilim Dalı
dc.subject.ytmIncubator
dc.subject.ytmInfant
dc.subject.ytmInfant-premature
dc.subject.ytmVital statistics
dc.subject.ytmNoise
dc.subject.ytmCover
dc.identifier.yokid10239818
dc.publisher.instituteSağlık Bilimleri Enstitüsü
dc.publisher.universityMALTEPE ÜNİVERSİTESİ
dc.identifier.thesisid565954
dc.description.pages71
dc.publisher.disciplineÇocuk Sağlığı ve Hastalıkları Hemşireliği Bilim Dalı


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess