dc.description.abstractAmaç: Koklear implant cerrahisi gerek ameliyat sırasında gerekse ameliyat sonrası erken ve geç dönemde önemli komplikasyonları olabilen bir cerrahidir. Bunlar arsında vestibüler sistem şikayetleri özel öneme sahiptir. Bu çalışmanın amacı koklear implant cerrahisi uygulanan hastalarda uzun dönemde vestibüler sistemin çalışmasını değerlendirmektir.Plan: Prospektif, kontrol gruplu, klinik çalışma.Yer: Konya Başkent Üniversitesi Tıp Fakültesi KBB KliniğiHastalar: Çalışmamıza 18 yaş altı takip edilen ve koklear implant uygulandıktan sonra bir yıl geçen 35 hasta ve hikayesinde vestibüler sistemle ilgili herhangi bir yakınması olmayan 35 gönüllü 18 yaş altı sağlıklı kişi dahil edildi.Yöntem: Çalışmaya dahil edilen koklear implantlı hasta ve sağlıklı gruba, her iki kulaklarına servikal ve oküler VEMP yapılarak gruplar arası karşılaştırıldı.Bulgular: Koklear implantlı çocuklarda cVEMP dalgası elde edilme oranları ve P1 latansları opere edilen ve karşı kulak arasında istatistiksel anlamlı bir fark göstermedi (sırasıyla p=0,802 ve p=0,123). Diğer taraftan kontrol grubu kulaklarda cVEMP dalgası implantlı olgularda hem opere taraf hem de karşı kulak ile karşılaştırıldığında anlamlı olarak yüksek oranda elde edildi. P1 latans değerlerinin karşılaştırılmasında ise opere taraf değerleri kontrol grubuna göre anlamlı oranda kısa bulunurken (p=0,046), karşı kulak ile sağlıklı çocukların kulaklarının karşılaştırılmasında iki grup arasında fark yoktu (p=0,746). Servikal VEMP bulgularına benzer şekilde, koklear implantlı çocuklarda oVEMP dalgası elde edilme oranları ve P1 latansları opere edilen ve karşı kulak arasında anlamlı bir fark yoktu (sırasıyla p=0,078 ve p=0,851). Kontrol grubu kulaklarda oVEMP dalgası implantlı olgularda hem opere taraf hem de karşı kulak ile karşılaştırıldığında anlamlı olarak yüksek oranda elde edildi. N1 latans değerlerinin karşılaştırılmasında ise iki grup arasında fark yoktu (p>0,05).Sonuç: Hastaların operasyon öncesi mevcut olan kohlear etkilenim kadar vestibüler son organda da etkilenmelerin olması, cerrahi sırasında hasar oluşması denge sorunlarının oluşmasında önemli nedenler olarak görünmektedir. Semptomların önemli bir kısmı geçici ve orta şiddette olmaktadır. Tedavide uygun egsersizler ve medikal tedavi ile şikayetlerde büyük oranda azalma ya da kaybolma sağlanmaktadır. Anahtar kelimeler: koklear implant; komplikasyon; vemp;
dc.description.abstractObjective: Cochlear implantation is an operation in which important complications can take place in both peroperative, early and late postperative periods. Among these vestibular complaints have special consideration. The aim of tis study was to evaluate the long therm functions of vestibular system in patients underwent cochlear implantation surgery. Planing : Prospective, controlled clinical study.Center: Başkent University, Faculty of Medicine, Otolaryngology Deparment, KonyaStudy Group:Thirty five patients under 18 years old with cochlear implantation after after at least a year from the operation were included to the study. Contro group included 35 voluntary patients under 18 years who had no complaint about vestibular system.Method : Cervical and ocular VEMP vestibular evoked myogenic patentials testing were achieved in both control and cochlear implantation groups. Results were compared between the groups. Results: Rate of Existence of cVEMP and P1 latency in children with implants did not significontly differ in between the operated and non operated ears(p=0,802 and p=0,123 respedively). On the other hand in control group, c VEMP significonly was highly achiaevable compared to both operated and non operated ears of children with cochlear implants. P1 latancies of operated ears were significontly shorter than the contro group(p=0,046). There were no significont difference between the P1 latancies of control group and non operated ears of study group(p=0,746). As c VEMPS, rate of existence of o VEMP and P1 latancies in children with cochlear implants did not significontly diffe in between the operated nonoperated ears(respectively p=0,078 and p=0,851). In control group, o VEMP was significontly high achievable compaierd to both operated and nonoperated ears of children with cochlear implantation. There were no statisticaly significont difference between n1 latencies of the two groups (p>0,05). Conclusion : Possible vestibular and organ impairments of the patients as in cochlear functions and possible vestibular damage during the operation are important factors about postoperative vestibular functions. Most of the symptomps are transient and moderate. With propriate physical exercises and madical therapy considerable improvement can be achieved in vestibular complaints.en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectKulak Burun ve Boğaztr_TR
dc.subjectOtorhinolaryngology (Ear-Nose-Throat)en_US
dc.titleKoklear implant(biyonik kulak) cerrahisi sonrası uzun dönem vestibüler fonksiyonların vestibüler uyarılmış kas cevapları ile değerlendirilmesi
dc.title.alternativeEvaluation of long term vestibular functions by using vestibular evoked myogenic potentials after cochlear implantation(bionic ear)
dc.typemasterThesis
dc.date.updated2020-01-12
dc.contributor.departmentKulak Burun Boğaz Anabilim Dalı
dc.subject.ytmVestibular function tests
dc.subject.ytmCochlear implants
dc.subject.ytmComplications
dc.subject.ytmSurgery
dc.subject.ytmSurgery-otorhinolaryngologic
dc.subject.ytmPostoperative complications
dc.identifier.yokid10127484
dc.publisher.instituteSağlık Bilimleri Enstitüsü
dc.publisher.universityBAŞKENT ÜNİVERSİTESİ
dc.identifier.thesisid449080
dc.description.pages55
dc.publisher.disciplineOdyoloji ve Konuşma Bozuklukları Bilim Dalı


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess