Sağlıklı erişkin bireylerde LS CE-chirp uyaran ve klik uyaran ile kaydedilen ekstra-timpanik elektrokokleografi yanıtlarının karşılaştırılması
dc.contributor.advisor | Erbek, Hatice Seyra | |
dc.contributor.author | Arslantaş, Mehmet Recai | |
dc.date.accessioned | 2020-12-04T08:19:21Z | |
dc.date.available | 2020-12-04T08:19:21Z | |
dc.date.submitted | 2018 | |
dc.date.issued | 2018-10-23 | |
dc.identifier.uri | https://acikbilim.yok.gov.tr/handle/20.500.12812/65472 | |
dc.description.abstract | Giriş ECochG ölçümleri; Méniere hastalığı, İşitsel nöropati spektrum bozukluğu tanısınınkonulması ve lezyon tarafının belirlenmesi, intraoperatif monitörizasyon ve koklearimplant öncesi değerlendirmeler gibi farklı klinik uygulamalarda kullanılmaktadır. Buçalışmada sağlıklı bireyler, yeni geliştirilen LS CE-Chirp uyaran ve klik uyaran ileekstra-timpanik elektrokokleografi ölçüm metodu kullanılarak test edilmiş ve sonuçlarkarşılaştırılmıştır.Materyal ve Metod Bu çalışma Ankara Başkent Üniversitesi Hastanesi KBB Anabilim dalı kliniğindeyapılmıştır. Çalışma grubunda 18 – 40 yaş arasında normal işitmeye sahip, 19 kadın(38 kulak) ve 4 erkek (8 kulak), toplam 23 kişi (46 kulak) dahil edilmiştir. Çalışmayadahil edilen gönüllü bireylerin ayrıntılı bir anamnezi alınmış, kulak burun boğazmuayanesi yapılarak herhangi bir patoloji saptanmamış, odyometri testi veimmitansmetri ölçümleri yapılıp işitmesinin normal olduğu görüşmüş ve gönüllülerintest kriterlerine uygun olduğu ispatlandıktan sonra ECochG testleri yapılmıştır.Yapılan ECochG testleri klik ve LS CE-Chirp uyaranlar kullanılarak 90, 80 ve 70 dBnHL şiddetlerinde yapılmıştır. Elde edilen değerler, verilerin dağılımına uygun olarakistatistiksel olarak değerlendirilmiştir. Bulgular Hem klik hem de LS CE-Chirp uyaran kullanılarak ECochG testi yapılmıştır. 90 dBnHL şiddetinde SP/AP oranı, 80 dB nHL şiddetinde AP latansı, 70 dB nHL şiddetindeAP latansı ve SP/AP oranı değerlerinde klik ve LS CE-Chirp uyaranlarda istatistikselolarak farklılık görülmüştür. Sonuç Altın folyo kaplı tip trode elektrot aracılığı ile LS CE-Chirp ve klik uyaranlarıkullanılarak yapılan ECochG testleri sonucunda istatiksel fark elde edilmiştir. Anahtar Kelimeler: Elektrokokleografi, ECochG, LS CE-Chirp | |
dc.description.abstract | Introduction ECochG testing is used for Méniere disease, auditory neuropathy spectrum disorderdiagnosis, defining the side of the lesion, intraoperative monitorization and pre coclearimplantation assesments in clinics. In this study, healty subjects were tested andevaluated with extra-tympanic electrocochleography method using LS CE-Chirp andclick stimulus. Material and Method This study is held by Ankara Başkent University Hospital in the department of ENT.The work group was 19 woman (38 ears) and 4 men (8 ears), total of 23 subjects withthe age range 18 – 40. All subjects anemnesis were taken in details and complete ENTexaminations were done. ECochG testings were done after being sure there is nopathology with each subject, audiometric and immitansmetric testings were performedand all were confirmed to have healthy hearing. ECochG tests were performed with90, 80 and 70 dB nHL levels using click and LS CE-Chirp stimuluses. All acquireddata were analysed statistically according to the data distribution. Results Statistically significant values were acquired for ECochG testing with 90 dB nHLSP/AP ratio, 80 dB nHL AP latency, 70 dB nHL AP latency and SP/AP ratio by theuse of click and LS CE-Chirp stimuluses. Conclusion ECochG test performed by the use of gold foil covered tip trode electrode, LS CEChirp and clickstimulus had statistically significant results. Key words: Electrocochleography, ECochG, LS CE-Chirp This study is held by the ethical committee permission of Başkent University Medicine& Health Sciences Research Committee (Project number: KA17/163, dated:12/07/2017 & issued 17/59). | en_US |
dc.language | Turkish | |
dc.language.iso | tr | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Attribution 4.0 United States | tr_TR |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject | Kulak Burun ve Boğaz | tr_TR |
dc.subject | Otorhinolaryngology (Ear-Nose-Throat) | en_US |
dc.title | Sağlıklı erişkin bireylerde LS CE-chirp uyaran ve klik uyaran ile kaydedilen ekstra-timpanik elektrokokleografi yanıtlarının karşılaştırılması | |
dc.title.alternative | Comparison of extra-tympanic electrocochleography test results using LS CE-chirp & clik stimulus in healty adult subjects | |
dc.type | masterThesis | |
dc.date.updated | 2018-10-23 | |
dc.contributor.department | Kulak Burun Boğaz Hastalıkları Anabilim Dalı | |
dc.subject.ytm | Meniere disease | |
dc.subject.ytm | Audiometry-evoked response | |
dc.subject.ytm | Audiometry | |
dc.subject.ytm | Evoked potentials-auditory | |
dc.subject.ytm | Acoustic impedance tests | |
dc.identifier.yokid | 10182975 | |
dc.publisher.institute | Sağlık Bilimleri Enstitüsü | |
dc.publisher.university | BAŞKENT ÜNİVERSİTESİ | |
dc.identifier.thesisid | 493233 | |
dc.description.pages | 65 | |
dc.publisher.discipline | Odyoloji Bilim Dalı |