Manyetik rezonans görüntüleme yapılan hastalarda gürültünün periferik işitme organına olası etkisinin otoakustik emisyon cihazı ile değerlendirilmesi
dc.contributor.advisor | Erbek, Hatice Seyra | |
dc.contributor.author | Turay, Cevahir Bulut | |
dc.date.accessioned | 2020-12-04T08:17:11Z | |
dc.date.available | 2020-12-04T08:17:11Z | |
dc.date.submitted | 2020 | |
dc.date.issued | 2020-06-17 | |
dc.identifier.uri | https://acikbilim.yok.gov.tr/handle/20.500.12812/65240 | |
dc.description.abstract | Bu çalışmanın amacı, sağlıklı işiten bireylerde manyetik rezonans görüntüleme(MRG) gürültüsü maruziyeti öncesi ve sonrasında işitmeyi objektif ve subjektifodyolojik yöntemler ile değerlendirerek MRG cihazının yaydığı gürültünün işitmeüzerine etkisini saptamaktır.Çalışmaya 18-50 yaş arası, otoskopik muayenesi ve timpanogramı normal olan,işitme kaybı olmayan toplam 38 hasta dahil edildi. Tüm hastaların muayeneleriyapıldıktan sonra MRG öncesi ve sonrası saf ses odyometrisi, konuşma odyometrisiyüksek frekans odyometrisi, transient evoked otoakustik emisyon (TEOAE) vedistorsion product otoakustik emisyon (DPOAE) testleri yapıldı.Çalışmamızda TEOAE, saf ses odyometrisi, konuşma odyometrisi, yüksekfrekans odyometrisi sonuçları karşılaştırıldığında hastaların MRG öncesi ve sonrası,işitme eşiklerinde anlamlı bir farklılık gözlenmedi. DPOAE ölçümlerinde; 4 kHzfrekansta sol kulakta MRG öncesi ortanca değeri 13,6 SNR iken MRG sonrası 15,7SNR olarak bulunmuştur (p>0,05). Sağ kulakta ise MRG öncesi ortanca değeri 14,1SNR iken MRG sonrası 13,2 SNR olarak bulunmuştur (p<0,05). Diğer frekanslardaise MRG öncesi ve sonrası ölçümler arasında anlamlı fark bulunamamıştır.DPOAE ölçümleri sonucunda elde ettiğimiz 4kHz frekansındaki etkilenmeyegöre MRG esnasında kullanılan kulak üstü kulaklıkların hastaları gürültüdenkorumada ne derece etkin olduğunun araştırılması gerektiğini düşünmekteyiz. MRGcihazının yarattığı gürültünün işitmeye olan etkisini tam olarak anlayabilmek dahakapsamlı çalışmalar yapılmalıdır.Anahtar Sözcükler: Manyetik Rezonans Görüntüleme (MRG), İşitme YüksekFrekans Odyometrisi, Transient Evoked Otoakustik Emisyon (TEOAE), DistorsionProduct Otoakustik Emisyon (DPOAE) | |
dc.description.abstract | The aim of this study is to evaluate the effect of noise produced by magneticresonance imaging (MRI) device on hearing by using objective and subjectiveaudiological assesments.A total of 38 patients between the ages of 18 and 50, who had normal otoscopicexamination and normal tympanogram wtihout hearing loss were included. Afterotoscopic examination; pure tone audiometry, speech audiometry, high requencyaudiometry, transient evoked otoacoustic emissions (TEOAE) and distortion productotoacoustic emission (DPOAE) tests were performed before and after MRI to allpatients.There was no statistically significant differences in TEOAE, pure tone audiogram,high frequency audiogram and speech audiogram tresholds before and after MRI.DPOAE results at 4kHz were significantly differerent before and after MRI. On leftear median values were 13,6 and 15,7 before and after MRI consecutively. On theright ear median values were 14,1 and 13,2 before and after MRI consecutively.There was no statistically significant difference in other frequencies in DPOAE.Based on the difference at 4 kHz frequency on DPOAE; earphones may besufficiently protect the patients from the MRI noise and this issue should deservefurther research. In order to completely undertstand the effect of MRI noise onhearing; more comprehensive studies should be performedKeywords: Magnetic Resonance Imaging (MRI), Hearing, High FrequencyAudiometry, Transient Evoked Otoacoustic Emissions (TEOAE),Distortion ProductOtoacoustic Emissions (DPOAE). | en_US |
dc.language | Turkish | |
dc.language.iso | tr | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Attribution 4.0 United States | tr_TR |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject | Kulak Burun ve Boğaz | tr_TR |
dc.subject | Otorhinolaryngology (Ear-Nose-Throat) | en_US |
dc.title | Manyetik rezonans görüntüleme yapılan hastalarda gürültünün periferik işitme organına olası etkisinin otoakustik emisyon cihazı ile değerlendirilmesi | |
dc.title.alternative | Evaluation of the possible effect of noise on theperipheral hearing organ on magnetic resonance i̇maging patients with autoacoustic emmission device | |
dc.type | masterThesis | |
dc.date.updated | 2020-06-17 | |
dc.contributor.department | Kulak Burun Boğaz Hastalıkları Anabilim Dalı | |
dc.identifier.yokid | 10327600 | |
dc.publisher.institute | Sağlık Bilimleri Enstitüsü | |
dc.publisher.university | BAŞKENT ÜNİVERSİTESİ | |
dc.identifier.thesisid | 609931 | |
dc.description.pages | 71 | |
dc.publisher.discipline | Odyoloji Bilim Dalı |