dc.contributor.advisor | Hayran, Yeliz | |
dc.contributor.author | Hazir Tekin, Yadel | |
dc.date.accessioned | 2021-05-07T12:00:58Z | |
dc.date.available | 2021-05-07T12:00:58Z | |
dc.date.submitted | 2017 | |
dc.date.issued | 2018-08-06 | |
dc.identifier.uri | https://acikbilim.yok.gov.tr/handle/20.500.12812/617202 | |
dc.description.abstract | Zirkonya esaslı tam seramik ve metal destekli seramik kronların marjinaluyumlarının ve çiğneme simülatörü sonrası aşınma miktarlarının değerlendirilmesiAmaç: Bu çalışmanın amacı farklı monolitik zirkonya ve metal destekliseramiklerin marjinal uyumlarının ve yaşlandırma işlemlerinden sonra aşınmamiktarlarının değerlendirilmesidir.Yöntem: Çalışmamızda, Katana® UTML, Prettau®, Zenostar® T, InCoris® TZI,BruxZir® (0,5 mm, 0,8 mm, 1 mm, 1,5 mm) monolitik zirkonya ve kontrol grubu olarakmetal destekli seramik kullanıldı. Her bir gruptan 10'ar adet kron elde edilerek toplam 9grup oluşturuldu. Örneklerin simantasyonu öncesi silikon replika tekniği ile stereomikroskop kullanılarak marjinal aralık ölçümleri yapıldı. Marjinal aralık ölçümlerininardından örnekler, termal siklusta (5-55 oC, 10 000 siklus) yaşlandırıldı. Aşınma testi;çiğneme simülatöründe (50N, 1 Hz, lateral hareket: 2 mm, ağız açıklığı: 2 mm) metalantagonistlerle, distile su solüsyonu içinde, 12 aylık süreyi yansıtan 240 000 siklusuygulanacak şekilde gerçekleştirildi. Örneklerin aşınmaları lazer tarayıcı ve üç boyutluçakıştırma yapabilen yazılım programı kullanılarak değerlendirildi. Ortalamalar vestandart deviasyonlar hesaplandı. İstatistiksel analiz; tek yönlü varyans analizi veanlamlı sonuçlanan tek yönlü varyans analizi sonrası çoklu karşılaştırma için TukeyHSD ve Tamhane T2 testi ile gerçekleştirildi (α=0,05).Bulgular: Örneklerin marjinal aralık ölçümleri arasında anlamlı bir farklılıkbulundu (p<0,001). Yapılan ölçümlerde en düşük marjinal aralık değerini BruxZir®(1,5mm) monolitik zirkonya kronlar (46±9μm), en yüksek marjinal aralık değerini deZenostar® (92±22μm) gösterdi. Örneklerin aşınma ölçümleri arasında anlamlı birfarklılık olduğu belirlendi (p<0,05). Yapılan ölçümlerde en düşük aşınma değeriniBruxZir® (0,8 mm) monolitik zirkonya kronlar (0,96±0,81mm2), en yüksek aşınmadeğerini metal seramik kronlar (4,59±2,08 mm2) gösterdi.Sonuçlar: Monolitik zirkonya seramikler feldspatik porselenlerlekarşılaştırıldığında üstün aşınma davranışı sergilediler. Metal destekli ve monolitikzirkonya seramiklerin marjinal aralık ölçümleri klinik olarak kabul edilebilir sınırlariçerisindedir.Anahtar Kelimeler: Zirkonya, porselen, marjinal uyum, çiğneme simülatörü,aşınma | |
dc.description.abstract | ABSTRACTEvaluation of marginal discrepancy and wear behavior of zirconia based fullceramic and metal supported ceramic crowns after chewing simulatorAim: The aim of this study is to determine the marginal fit of differentmonolithic zirconia and metal-supported ceramics and their wear resistance after aging.Material and methods: The present study monolithic zirconias as Katana®UTML, Prettau®, Zenostar® T, InCoris® TZI, BruxZir® (0.5mm,0.8mm,1mm,1.5mm)and metal ceramic as a control group were used. A total of 9 groups (n=9) were formed.Before the cementation of the samples, marginal gap measurements were performedusing a stereo microscope with a silicon replica technique. Samples were then aged withthermal cycling (5-55 oC,10000cycles). Wear tests were performed by using chewingsimulator (50N,1Hz,240000cycles,lateral movement:2mm,mouth opening:2mm) withmetal antagonists in distilled water solution. The samples were evaluated using a laserscanner and a software program capable of three-dimensional registration. Statisticalanalysis was performed using one-way analysis of variance (ANOVA) and Tukey HSDor Tamhane T2 test for multiple comparisons (α=0.05).Results: There was a significant difference between marginal gap measurementsof the samples (p<0.001). In the measurements, the lowest marginal range value wasfound in BruxZir® (1.5mm) monolithic zirconia crowns (46±9μm) and the highestmarginal range value was detected in Zenostar® (92±22μm). A significant differencewas found between the wear measurements of the samples (p<0.05). In themeasurements, the lowest wear value was seen in BruxZir® (0,8mm) monolithiczirconia crowns (0.96±0.81mm2) and the highest one was found in metal ceramiccrowns (4.59±2.08mm2).Conclusions: Zirconia ceramics exhibited superior wear behaviors whencompared to feldspar porcelain. The marginal gap measurements of metal supported andzirconia ceramics are within clinically acceptable limits.Keywords: Zirconia, porcelain, marginal discrepancy, chewing simulator, wear | en_US |
dc.language | Turkish | |
dc.language.iso | tr | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Attribution 4.0 United States | tr_TR |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject | Diş Hekimliği | tr_TR |
dc.subject | Dentistry | en_US |
dc.title | Zirkonya esaslı tam seramik ve metal destekli seramik kronların marjinal uyumlarının ve çiğneme simülatörü sonrası aşınma miktarlarının değerlendirilmesi | |
dc.title.alternative | Evaluation of marginal discrepancy and wear behavior of zirconia based full ceramic and metal supported ceramic crowns after chewing simulator | |
dc.type | doctoralThesis | |
dc.date.updated | 2018-08-06 | |
dc.contributor.department | Protetik Diş Tedavisi Ana Bilim Dalı | |
dc.subject.ytm | Dental restoration | |
dc.subject.ytm | Dental materials | |
dc.subject.ytm | Dental porcelain | |
dc.subject.ytm | Dental occlusion | |
dc.subject.ytm | Crowns | |
dc.subject.ytm | Zirconium oxide | |
dc.subject.ytm | Wear | |
dc.identifier.yokid | 10141786 | |
dc.publisher.institute | Diş Hekimliği Fakültesi | |
dc.publisher.university | GAZİOSMANPAŞA ÜNİVERSİTESİ | |
dc.type.sub | dentistThesis | |
dc.identifier.thesisid | 454028 | |
dc.description.pages | 130 | |
dc.publisher.discipline | Diğer | |