dc.description.abstractiv3/&<$5',0,</$257$*(5ø/ø0(1(5-ø'$ö,7,07$/ø+$7/$5,1'$$5,=$$1$/ø=øùHEQHP7h5(Elektrik-(OHNWURQLN0ÂKHQGLVOL÷L<ÂNVHN/LVDQV7H]L7H]'DQÃúPDQÃ<DUG'Ro'U<ÃOPD]$6/$1ÖZET%X oDOÃúPDGD KDYDL HQHUML GD÷ÃWÃP KDWODUÃQGD SURJUDPODQDELOLU PDQWÃNVDO NRQWUROU3URJUDPPDEOH /RJLF &RQWUROOHU 3/& YH %LOHúHQOHU )DUNà /QWHPL NXOODQÃODUDN úQW DUÃ]DODUWHVSLWHGLOPLúYHWUDQVIRUPDWUPHUNH]LQHRODQPHVDIHOHULKHVDSODQPÃúWÃU*HOLúWLULOHQ/QWHPGHWDOL KDWODUGDQ HOGH HGLOHQ DNÃP ELOJLOHUL 3/& NXOODQÃODUDN J]OHPOHQPHNWH YH KDW EDúÃQGDEXOXQDQDQDELOJLVD/DULOHHNUDQODQPÃú6KLHOGHG7ZLVWHG3DLU673NDEOR/DUGÃPÃ/ODGHYDPOÃKDEHUOHúPH VD÷ODQPDNWDGÃU *HOLúWLULOHQ /QWHPGH oHúLWOL DUÃ]D WLSOHUL DUÃ]D GLUHQoOHUL YH KDWsonu kaynak kapasiteleri için Electro-0DJQHWLF 7UDQVLHQWV %HQ]HWLP 3URJUDPà (073NXOODQÃODUDNWHVWHGLOPLúWLUAnahtar Kelimeler: $UÃ]D /HUL EXOPD %LOHúHQOHU )DUNà <QWHPL (QHUML 'D÷ÃWÃP +DWODUÃ3URJUDPODQDELOLU0DQWÃNVDO.RQWUROU3/&
dc.description.abstractv$'ø*ø7$/)$8/7/2&$7ø21$1'021ø725,1*7(&+1ø48(86ø1*352*5$00$%/(/2*ø&&21752//(53/&)25OVERHEAD POWER DISTRIBUTION SYSTEMSùHEQHP7h5(Electrical and Electronic Engineering, M. S. Thesis, 20057KHVLV6XSHUYLVRU$VVRF3URI'U<ÃOPD]$6/$1SUMMARYIn this study, a digital fault location and monitoring technique using ProgrammableLogic Controller (PLC) for overhead power distribution lines is presented. This techniqueemploys pre- and post-fault current and voltage information along with data from laterals. Inthis method a knowledge based algorithm is incorporated to the superimposed componentsbased fault location and monitoring algorithm to locate shunt faults in radial power distributionlines with sub-feeders. By transferring current information from sub-feeders to the substation,through Shielded Twisted Pair (STP) cables the possibility of multiple fault point locations areeliminated. The effectiveness of this method is tested with Electro-magnetic Transients Program(EMTP) simulations.Key Words: Fault Location, Programmable Logic Controllers, Power Distribution Feeders,Superimposed Components,en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectElektrik ve Elektronik Mühendisliğitr_TR
dc.subjectElectrical and Electronics Engineeringen_US
dc.titleProgramlanabilir mantıksal kontrolör (PLC) ile orta gerilim enerji dağıtım tali hatlarında arıza analizi
dc.title.alternativeA digital fault location and monitoring technique using programmable logic controller (PLC) for overhead power distribution systems
dc.typemasterThesis
dc.date.updated2018-08-06
dc.contributor.departmentDiğer
dc.identifier.yokid196443
dc.publisher.instituteFen Bilimleri Enstitüsü
dc.publisher.universityDUMLUPINAR ÜNİVERSİTESİ
dc.identifier.thesisid198259
dc.description.pages78