dc.description.abstract23 Gauge transkonjonktival sütürsüz vitrektomiden sonra korneal biyomekanik parametrelerdeki değişikliklerin incelenmesiAmaç: 23 gauge transkonjonktival sütürsüz vitrektomi (23 G TSV) yapılan hastaların korneal biomekanik parametrelerinde cerrahi olarak indüklenen değişikliklerin araştırılması amaçlandı.Metod: Kliniğimizde 23 G TSV yapılan 29 hastanın 29 gözü çalışmaya dahil edildi. Ocular Response Analizer ile korneal histerezis (CH), korneal rezistans faktör (CRF), Goldmann ile korele göz içi basıncı (GİBg) ve korneal kompanse GİB (GİBcc), korneal topografi ile simulated K ve bu değerler kullanılarak cerrahi olarak indüklenen astigmatizma ameliyat öncesinde ve ameliyattan sonra 1. ve 3. ayların sonunda ölçüldü. Ölçülen bu parametreler arasındaki değişiklikler istatistiksel olarak değerlendirildi.Bulgular: Preoperatif ve postoperatif 1. ve 3. aylarda ortalama CRF ve GİBg parametrelerinde istatistiksel anlamlı fark yoktu. Preoperatif ve postoperatif 1. ve 3. aylarda ortalama CH sırasıyla 9.12±1.83 mmHg, 8.15±2.16 mmHg, 8.55±1.61 mmHg idi (p=0.04, p=0.11 ve p=0.25, sırasıyla). Preoperatif ve postoperatif 1. ve 3. aylarda ortalama GİBcc sırasıyla 17.72±6.23 mmHg, 20.28±6.50 mmHg, 18.74±5.76 mmHg idi (p=0.03, p=0.45 ve p=0.23, sırasıyla). Preoperatif ve postoperatif 1. ay arasında ortalama CH ve GİBcc parametrelerinde istatistiksel anlamlı fark saptandı (p=0.04 ve p=0.03, sırasıyla). Preoperatif ve postoperatif dönemlerdeki ortalama Sim K değerleri arasında istatistiksel anlamlı fark saptanmadı. Postoperatif 1. ve 3. aydaki cerrahi olarak uyarılmış astigmatizma değerleri 1.98 ± 1.20 D ve 3.22 ± 1.77 D bulundu.Sonuç: Erken postoperatif dönemde CH'nin azalmasına ve GİBcc'nin artmasına rağmen, postoperatif 3.ayda parametreler preoperatif değerlere ulaşmıştır. Sonuç olarak; 23 G TSV ameliyatı geç postoperatif dönemde korneal biyomekanik parametrelerde önemli değişikliğe neden olmayan minimal invaziv bir vitreoretinal cerrahi tekniktirAnahtar Kelimeler: korneal histerezis, korneal rezistans faktör, ORA, vitrektomi.
dc.description.abstractSurgically Induced Changes in Corneal Biomechanical Parameters After 23 Gauge Pars Plana VitrectomyPurpose: To evaluate surgically induced changes in corneal biomechanical properties of patients undergoing 23 gauge transconjunctival sutureless vitrectomy (23 G TSV).Methods: We prospectively examined 29 eyes of 29 patients who underwent 23 G TSV. Corneal biomechanical properties, including corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (İOPg) and corneal compensated intraocular pressure (İOPcc) were measured by Ocular Response Analyser (ORA) before, 1 and 3 months postoperatively. Topographic mesaurements were obtained and recorded at the same time periods. Taking these mesaurements into account, induced astigmatism values were determined. The ORA and topographic measurements before and after the surgery were compared statistically.Results: There were no statistically significant difference between the preoperative and postoperative mean CRF and IOPg measurements in the study group. Mean CH was 9.12±1.83 mmHg preoperatively, 8.15±2.16 mmHg 1 month and 8.55±1.61 mmHg 3 months postoperatively (p=0.04, p=0.11 and p=0.25, respectively). The mean IOPcc was 17.72±6.23 mmHg preoperatively, 20.28±6.50 mmHg 1 month and 18.74±5.76 mmHg 3 months postoperatively (p=0.03, p=0.45 and p=0.23, respectively). There were significant differences between preoperative and 1-month postoperative mean CH and IOPcc measurements (p=0.04 and p=0.03, respectively). There were no statistically significant difference between the preoperative and postoperative mean Sim K values. Surgically induced astigmatism was 1.98 ± 1.20 D and 3.22 ± 1.77 D at postoperative 1 and 3 months respectively.Conclusion: Although CH decreased and IOPcc increased in the early postoperative period, the parameters reached preoperative values by 3 months postoperatively, showing that corneal biomechanical properties are not influenced by 23 G TSV which is a minimal invasive vitreoretinal surgical technique.Keywords: corneal hysteresis, corneal resistance factor, ORA, vitrectomy.en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectGöz Hastalıklarıtr_TR
dc.subjectEye Diseasesen_US
dc.title23 gauge transkonjonktival sütürsüz vitrektomiden sonra korneal biyomekanik parametrelerdeki değişikliklerin incelenmesi
dc.title.alternativeSurgically induced changes in corneal biomechanical parameters after 23 gauge pars plana vitrectomy
dc.typedoctoralThesis
dc.date.updated2018-08-06
dc.contributor.departmentGöz Hastalıkları Ana Bilim Dalı
dc.subject.ytmVitrectomy
dc.subject.ytmCornea
dc.subject.ytmCorneal diseases
dc.subject.ytmSurgery-eye
dc.subject.ytmBiomechanics
dc.identifier.yokid420136
dc.publisher.instituteTıp Fakültesi
dc.publisher.universityCELÂL BAYAR ÜNİVERSİTESİ
dc.type.submedicineThesis
dc.identifier.thesisid303462
dc.description.pages42
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess