Show simple item record

dc.contributor.advisorKaptan, Arife
dc.contributor.authorÇukurcu, Çiğdem
dc.date.accessioned2021-05-07T08:53:25Z
dc.date.available2021-05-07T08:53:25Z
dc.date.submitted2019
dc.date.issued2020-01-27
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/599228
dc.description.abstractBu çalışmada, farklı yapıdaki cam iyonomer esaslı dört farklı restoratif materyalin (Dyract XP, Photac Fil Quick Aplicap, GC Fuji II LC ve GCP Glass Fill) polimerizasyonu esnasında pulpal mikrosirkülasyon taklit edilerek, farklı dentin kalınlıklarında süt dişi pulpa odasında meydana gelen sıcaklık değişikliklerinin değerlendirilmesi amaçlanmıştır.Çalışmamızda kullanılan 80 adet çürüksüz süt molar dişine, paralelometre cihazı yardımı ile 3x3 mm genişliğinde ve 2 mm derinliğinde sınıf I kaviteler açıldı. Örnekler kavite tabanı ve pulpa odası tavanı arasında kalan dentin kalınlığı 1 mm ve 2 mm olmak üzere iki gruba ayrıldı. Her bir restoratif materyal, 1 mm ve 2 mm dentin kalınlığında 10'ar örnek olacak şekilde üretici firma talimatları doğrultusunda kavitelere yerleştirildi ve ışık cihazlarıyla (Valo LED, GCP Carbo-LED) polimerizasyonları gerçekleştirildi. Materyallerin polimerizasyonu esnasında pulpa odasında ortaya çıkan sıcaklık artışları, pulpal mikrosirkülasyonu taklit eden düzenekler kullanılarak, J tip termokupl ile ölçülerek kaydedildi. Verilerin istatistiksel olarak değerlendirilmesinde Varyans analizi ve Tukey testi kullanıldı.Çalışmada kullanılan restoratif materyallerin polimerizasyonu sırasında pulpa odasında ortaya çıkan sıcaklık değişiklikleri arasında istatistiksel olarak anlamlı farklılık bulundu (p<0,05). En düşük sıcaklık artış değerleri, 2 mm dentin kalınlığı bulunan örneklerde Dyract XP grubunda gözlenirken, en yüksek sıcaklık artışı 1mm dentin kalınlığına sahip GCP Glass Fill grubunda gözlendi. Restoratif materyallerin polimerizasyonu esnasında ortaya çıkan sıcaklık artışları farklı dentin kalınlığına sahip gruplar arasında istatistiksel olarak anlamlı farklılık gösterdi (p<0,05). En yüksek sıcaklık artış değerleri 1 mm dentin kalınlığına sahip gruplarda gözlendi.Kullanılan restoratif materyallerin polimerizasyonu sırasında ortaya çıkan sıcaklık değerlerinin, her iki dentin kalınlığında da pulpa için kritik değer olan 5,5 ºC'yi aşmadığı görüldü. Anahtar sözcükler: Süt dişi, Pulpal sıcaklık artışı, Dentin kalınlığı, Pulpal mikrosirkülasyon
dc.description.abstractThe purpose of this study is to evaluate the temperature changes in primary teeth pulp chamber with different dentin thicknesses during the polymerization of four glass ionomer based restorative materials (Dyract XP, Photac Fil Quick Aplicap, GC Fuji II LC and GCP Glass Fill).Eighty extracted, caries‑free, primary molars were prepared as occlusal cavities with a surface area of 3x3 mm and a depth of 2 mm by parallelometer device. The samples were divided into two groups as the thickness of the remaining dentin between the pulp chamber and the cavity floor were 1 mm and 2 mm. Each restorative material was placed in the cavities in accordance with the manufacturer's instructions, with 10 samples in each 1 mm and 2 mm dentin thicknesses, and polymerizations were performed with light devices (Valo LED, GCP Carbo-LED). During the polymerization of the materials, temperature increases in the pulp chamber were recorded by a J type thermocouple while using a pulpal microcirculation setup. Variance analysis and Tukey test were used for statistical evaluation of the data.There was a statistically significant difference between the temperature changes occurring in the pulp chamber during the polymerization of the restorative materials used in the study (p <0.05). The lowest temperature increase was observed in Dyract XP group with 2 mm dentin thickness while the highest temperature increase was observed in GCP Glass Fill group with 1mm dentin thickness. Dentin thicknesses was significantly associated with the temperature changes during the polymerization of the restorative materials (p <0.05). The highest temperature increase was observed in groups with 1 mm dentin thickness.The temperature changes during the polymerization of the restorative materials used did not exceed 5.5 ºC, which is critical for pulp at both dentin thicknesses.Keywords: Primary teeth, Pulpal temperature increase, Dentin thickness, Pulpal microcirculationen_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectDiş Hekimliğitr_TR
dc.subjectDentistryen_US
dc.titleFarklı yapıdaki cam iyonomer esaslı restoratif materyallerin polimerizasyonu esnasında süt dişi pulpa odasında oluşan sıcaklık değişikliklerinin değerlendirilmesi
dc.title.alternativeThe evaluation of the temperature changes in primary teeth pulp chamber during the polymerization of different glass ionomer based restorative materials
dc.typedoctoralThesis
dc.date.updated2020-01-27
dc.contributor.departmentÇocuk Diş Hekimliği Ana Bilim Dalı
dc.subject.ytmDental materials
dc.subject.ytmGlass ionomer cements
dc.subject.ytmDental restoration
dc.subject.ytmTooth deciduous
dc.subject.ytmDental pulp cavity
dc.subject.ytmDentin
dc.subject.ytmHeat change
dc.identifier.yokid10247340
dc.publisher.instituteDiş Hekimliği Fakültesi
dc.publisher.universityCUMHURİYET ÜNİVERSİTESİ
dc.type.subdentistThesis
dc.identifier.thesisid549364
dc.description.pages80
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess