dc.contributor.advisor | Özden, Ali Veysel | |
dc.contributor.author | Söylemez, Hüseyin Oğuzhan | |
dc.date.accessioned | 2021-05-06T13:06:56Z | |
dc.date.available | 2021-05-06T13:06:56Z | |
dc.date.submitted | 2020 | |
dc.date.issued | 2020-09-28 | |
dc.identifier.uri | https://acikbilim.yok.gov.tr/handle/20.500.12812/591979 | |
dc.description.abstract | Çalışmanın amacı, servikal manipülasyonu uygulamasında 27 fizyoterapistin, (15 erkek,12 kadın) Humerus ve Radius kemikleri arasındaki dirsek açısının, 60°, 90° ve 120°,manipülasyon hızına, kuvvetine, gücüne etkisinin değerlendirilmesi.Çalışmaya, kayropraktik mezun, tez aşamasında yada en az ikinci sınıf öğrencigönüllüler dahil edilmiştir. Çalışmada gönüllüler, Randomize olarak 1- 60°, 90° ve 120°(n=15, 6 kadın, 9 erkek), 2- 120°, 90° ve 60° (n=12, 6 kadın, 6 erkek), iki grubaayrılmıştır. gruplar arası karşılaştırmalarda Kruskal Wallis veya Mann Whitney Utestleri kullanılmıştır.Ölçümler sorasında cansız bir mankenin servikal bölgesine Microfet 2 wifi dinamometresin ve cihazın uygulama programı Ficrofet 2 Clinical by Hoggan HealthIndustries, programı bilgisayara yüklenerek ölçümler kayıt altına alınmıştır. Humerus veRadius arasındaki dirsek açısının ölçülmesinde analog goniometre kullanılmıştır.Elde edilen sonuçlara göre 60°, 90° ve 120° derecelik açılar arasında uygulanan kuvvetaçısından istatistiksel olarak anlamlı farklılık bulunmaktadır (p<0.05). Açı arttıkçakuvvet azalmaktadır. Hangi açılar arasında farklılık olduğunu anlamak amacıyla yapılanikili karşılaştırmalar sonucunda 60° uygulanan kuvvetin 120° uygulanan kuvvete göreanlamlılık yaratacak şekilde daha yüksek olduğu sonucu bulunmuştur. | |
dc.description.abstract | The aim of the study was to determine the angle of elbow between Humerus and Radiusbones (60 °, 90 ° and 120 °) in 27 physiotherapists (15 male, 12 female) in cervicalmanipulation. manipulation speed, strength, power to evaluate the effect.Volunteers who are chiropractic graduates, at thesis stage or at least second gradestudents were included in the study. Volunteers in the study were randomly assigned 1-60 °, 90 ° and 120° (n = 15, 6 female, 9 male), 2- 120 °, 90 ° and 60 ° (n = 12, 6 female,6 male), two divided into groups. Kruskal Wallis or Mann Whitney U tests were usedfor comparisons between groups.During measurements, microfet 2 wifi dynamo meter and Ficrofet 2 Clinical by HogganHealth Industries program were installed on a cervical area of a mannequin andmeasurements were recorded. Analog goniometer was used to measure the angle ofelbow between humerus and radius.According to the results, there is a statistically significant difference between the anglesof 60°, 90 ° and 120 ° in terms of applied force (p <0.05). As the angle increases, theforce decreases. In order to understand which angles are different, it was found that the60 ° applied force was significantly higher than the 120 ° applied force | en_US |
dc.language | Turkish | |
dc.language.iso | tr | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Attribution 4.0 United States | tr_TR |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject | Fizyoterapi ve Rehabilitasyon | tr_TR |
dc.subject | Physiotherapy and Rehabilitation | en_US |
dc.title | Servikal manipülasyonda, kuvvet zaman grafiği vedirsek açısı arasındaki ilişkinin incelenmesi | |
dc.title.alternative | In cervical manuplation, investigation of the relationshipwi̇th the elbow angle on force time graphic | |
dc.type | masterThesis | |
dc.date.updated | 2020-09-28 | |
dc.contributor.department | Radyoloji Ana Bilim Dalı | |
dc.identifier.yokid | 10324540 | |
dc.publisher.institute | Sağlık Bilimleri Enstitüsü | |
dc.publisher.university | BAHÇEŞEHİR ÜNİVERSİTESİ | |
dc.identifier.thesisid | 637064 | |
dc.description.pages | 91 | |
dc.publisher.discipline | Kayropraktik Bilim Dalı | |