dc.description.abstractAmaç: Uykuda beyin yanıtlılığının, klasik uyku evreleme ve BİS sistemine göre farklı dönemlerde, işitsel uyaranlar aracılığıyla ve ?Uyarılma Potansiyelleri? yöntemi ile incelenmesi.Gereç ve Yöntem: Çalışmada 18 gönüllü bireyin uyku kayıtları incelendi (18-32 yaş, ort: 24.4 ± 3.6; 5 kadın). Uyku kayıtları sırasında basit işitsel uyaranlar (1500 Hz, 80 dB, 500 ms) kulak içine (etimotik) uygulandı. Klasik uyku skorlama ve BİS sistemine göre uyku dönemleri belirlendi ve her bir uyku döneminde işitsel uyarılma potansiyelleri (İUP) incelendi. N100, P200, N300, P450, N550 ve P900 yanıtlarının uyku dönemleri arasındaki değişimi araştırıldı.Bulgular: BİS sistemi ve klasik NREM uyku evreleri arasında, yüksek korelasyon olduğu saptandı. BİS sistemi ile uyku, klasik skorlama sistemlerine göre daha fazla sayıda dönemlerine ayrıldı ve İUP bileşenlerindeki değişim, daha fazla kademede incelendi. Özellikle, N100 bileşen genliğinde uyku derinleştikçe küçülme, N300 ve P900 bileşen genliklerinde ise büyüme görüldü. BİS ve NREM uyku evrelerinde elde edilen İUP arasında, yüksek korelasyon bulundu. Uykunun ilk ve ikinci yarısı arasında, İUP açısından farklılıklar olduğu gösterildi. İkinci yarı uykuda, yüzeyel uyku döneminde N100 genliğinin, derin uyku dönemlerinde ise P200 ve P900 genliklerinin küçüldüğü görüldü.Sonuç: Bu çalışma, BİS sistemi ile uykuda IUP'nin birlikte incelendiği ilk çalışma olma özelliğini göstermektedir. Bulgular, BİS sisteminin uyku dinamiğinin çalışılmasında, yararlı olabileceğini göstermiştir. Ayrıca uyku, BİS sistemi ile daha fazla alt dönemde incelenebildiği için İUP altında yatan süreçler, daha detaylı çalışılabilmiştir. Bu çalışmada BİS sistemi, klasik uyku evreleme sistemleri yerine değil, beraberinde kullanılmak üzere önerilmektedir.Uyku İUP bileşenlerinin altında yatan süreçleri anlayabilmek için daha çok kapsamlı çalışmaya ihtiyaç vardır. Dinamik İUP yöntemi ile BİS sisteminin birlikte kullanıldığı yeni çalışmalar, farklı uyku bozukluklarının altındaki patolojik süreçlerin aydınlatılmasında da fayda sağlayabilir.Anahtar Kelimeler: Uyku, Elektrofizyoloji, İşitsel Uyarılma Potansiyelleri, N100, P200, N300, P450, N550, P900
dc.description.abstractObjective: The aim of the present study is to investigate the brain responsiveness during different stages of sleep, which are scored according to classical sleep scoring and BIS systems, via auditory stimulations and ?Evoked Potentials?.Materials and Methods: In the study sleep recordings of 18 volunteer subjects were analyzed (18-32 year old, mean age: 24.4 ± 3.6; 5 females). During sleep recordings, auditory stimuli were applied into the ear channel (etymotic). Sleep stages were scored according to conventional sleep scoring systems and BIS system and in each of these stages Auditory Evoked Potentials (AEP) were analyzed. The alterations of N100, P200, N300, P450, N550 and P900 waveforms were investigated in different sleep stages.Results: A very high correlation factor was obtained between BIS system and classical NREM sleep stages. Sleep recordings were scored into more levels according to BIS system than conventional scoring systems. Deepening of sleep were followed by the decrease of N100 component amplitude, whereas N300 and P900 components? were found to be increased. Also, it has been found that, there was a very high correlation between AEPs which were scored according to classical methods and BIS system. Furthermore, it has been shown that, there was prominent differences in the first and second halves of sleep AEPs. In the second half of the sleep, N100 amplitude was higher in the light sleep and the amplitudes of P200 and P900 were higher in deep sleep stages.Conclusion: The present research is the first in studying BIS and AEPs together in sleep. The results showed that, BIS system may serve as a fruitful method in studying sleep dynamics. Furthermore, with the usage of BIS system, sleep could be analyzed in more stages which will in turn be useful studying the underlying processes of AEPs. In the present study, it was not the intention to claim that BIS system can replace classical staging methods, rather it is recommended as an accompanying method to sleep staging.Understanding the processes underlying the sleep AEPs needs further comprehensive researches. Future studies with dynamic AEPs and BIS system might also be beneficial in clarifying the pathological processes underlying sleep disorders.Key words: Sleep, Electrophysiology, Auditory Evoked Potentials, N100, P200, N300, P450, N550, P900en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/embargoedAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectBiyofiziktr_TR
dc.subjectBiophysicsen_US
dc.titleUyku dinamiğinin çoklu ses uyaranları ile incelenmesi
dc.title.alternativeInvestigation of sleep dynamics through multi-auditory stimuli
dc.typedoctoralThesis
dc.date.updated2018-08-06
dc.contributor.departmentBiyofizik Ana Bilim Dalı
dc.subject.ytmEvoked potentials-auditory
dc.subject.ytmElectrophysiology
dc.subject.ytmScales
dc.subject.ytmSleep
dc.subject.ytmSleep disorders
dc.identifier.yokid389352
dc.publisher.instituteSağlık Bilimleri Enstitüsü
dc.publisher.universityDOKUZ EYLÜL ÜNİVERSİTESİ
dc.identifier.thesisid281949
dc.description.pages123
dc.publisher.disciplineDiğer