Solid-state kardiyak gama kamera ile pet/bt`de miyokardiyal perfüzyon görüntülemedeki hareket artefaktlarının karşılaştırılması: Fantom çalışması
dc.contributor.advisor | Ayan, Arif Kürşad | |
dc.contributor.author | Dönmez, Semra | |
dc.date.accessioned | 2020-12-03T14:41:03Z | |
dc.date.available | 2020-12-03T14:41:03Z | |
dc.date.submitted | 2013 | |
dc.date.issued | 2018-08-06 | |
dc.identifier.uri | https://acikbilim.yok.gov.tr/handle/20.500.12812/54912 | |
dc.description.abstract | Solid-State Kardiyak Gama Kamera Gle Pet/Bt?de Miyokardiyal Perfüzyon Görüntülemedeki Hareket Artefaktlarının KarGılaGtırılması:Fantom ÇalıGması Amaç. Bu çalışmanın amacı, kardiyak gama kamera ile PET/BT.de miyokardiyal perfüzyon görüntülemedeki aksiyel yöndeki hasta hareketlerinden kaynaklanan artefaktların karşılaştırılması, olası hasta hareketlerinin hangi boyutta defekt oluşturabileceğinin bulunması, bu defektlerin toplam çekim süresinin hangi safhasında meydana gelebileceğini ve hangi sistemde yapılan kalp çalışmalarının daha güvenilir olduğunu araştırmaktır. Materyal ve Metot.Çalışmada Anthropomorphic SPECT kalp fantomu iki ayrı kamera sisteminde hasta hareketini simüle etmek için kullanılmıştır. Kalp fantomu her iki sistemde de tek gün protokolünde rest çalışması başladıktan sonra sırasıyla; çekim süresinin başında, ortasında ve sonunda hareketsiz, 4 mm, 12 mm ve 20 mm.lik hareket oluşturularak 10 kez tekrar edildi. Daha sonra her görüntü tek tek analiz edildikten sonra polar harita sonuçları üzerinden istatistiksel analiz yapıldı. Bulgular.Kardiyak gama kamera sonuçlarında çekim süresinin başında ve sonunda oluşturulan 4 mm, 12 mm ve 20 mm.lik hareketler ile hareketsiz çalışmalar arasında anlamlı fark bulunmadı. Çekim süresinin ortasında oluşturulan hareketler arasında istatistiksel olarak anlamlı bir fark bulundu (p<0.05). Post hoc analizlerde bu farkın 20 mm hareket oluşturulan grup ile hareketsiz ve 4 mm hareket oluşturulan gruptan kaynaklandığı anlaşılmıştır. PET/BT sisteminde ise çekim süresinin başında ve ortasında oluşturulan, 4 mm, 12 mm ve 20 mm.lik hareketler ile hareketsiz çalışmalar arasında istatistiksel fark bulunmadı. Çekim süresinin sonunda oluşturulan hareketler arasında ise istatistiksel olarak anlamlı bir fark bulundu. Post hoc analizlerde bu farkın | |
dc.description.abstract | The Comparison of Movements Artifacts in Myocardial Perfusion Scanning In Solid-State Cardiac Gamma Camera and PET/CT:Phantom Study Aim.The aim of this article is to compare the artifacts based on the patient movement while myocardial perfusion scanning with cardiac gamma camera and PET/CT, to determine the size of the defects which patient movement causes, to research at which shooting time phase these defects would occur and in which system the studies are more reliable. Material and Method.Anthropomorphic SPECT cardiac phantom is used to simulate the movement of the patient in two separate camera systems in this study. As soon as one day protocol rest study was started, cardiac phantom was repeated 10 times in both systems respectively; at the beginning, mid and end of shooting time without motion and 4mm, 12mm and 20mm with motion creating. After analyzing each image one by one, polar map was based on the results of statistical analysis. Results.According to cardiac gamma camera results; there was no statistical significant difference between 4mm, 12mm and 20mm of movements generated at the beginning and end of study. A statistically significant difference was found between the movements created in the mid of shooting time (p<0.05). It was understood in post hoc analysis that; this difference was derived from 20mm group without motion and 4mmgroup with motion. In PET/CT study; there was no statistically significant difference between 4mm, 12mm and 20mm of movements generated at the beginning and mid of study. A statistically significant difference was found between the movements created in the end of shooting time (p<0.05). It was understood in post hoc analysis that; this difference was derived from 20 mm group generated motion and 12mm group with motion. Conclusion.When the artifacts based on axial patient movement in MPS studies in cardiac gamma camera and PET/CT was compared, it was understood that cardiac gamma camera was more sensitive and reliable than PET/BT. Key Words: Anthropomorphic Phantom, Myocardial Perfusion Scintigraphy, PET/BT, Solid State Gama Kamera, SPECT | en_US |
dc.language | Turkish | |
dc.language.iso | tr | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Attribution 4.0 United States | tr_TR |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject | Fizik ve Fizik Mühendisliği | tr_TR |
dc.subject | Physics and Physics Engineering | en_US |
dc.title | Solid-state kardiyak gama kamera ile pet/bt`de miyokardiyal perfüzyon görüntülemedeki hareket artefaktlarının karşılaştırılması: Fantom çalışması | |
dc.title.alternative | The comparison of movements artifacts in myocardial perfusion scanning in solid-state cardiac gamma camera and pet/ct: Phantom study | |
dc.type | masterThesis | |
dc.date.updated | 2018-08-06 | |
dc.contributor.department | Nükleer Tıp Anabilim Dalı | |
dc.subject.ytm | Radionuclide imaging | |
dc.subject.ytm | Positron-emission tomography | |
dc.subject.ytm | Myocardium | |
dc.subject.ytm | Perfusion-regional | |
dc.identifier.yokid | 10004426 | |
dc.publisher.institute | Sağlık Bilimleri Enstitüsü | |
dc.publisher.university | ATATÜRK ÜNİVERSİTESİ | |
dc.identifier.thesisid | 334329 | |
dc.description.pages | 100 | |
dc.publisher.discipline | Diğer |