dc.description.abstractÖZET Bu çalışmada, enerji dispersiv (dağılımlı) x-ışını floresans (EDXRF) analizinde, numune içerisindeki analit ve matris konsantrasyonları değiştirilerek, şiddetlendirme etkisinin konsantrasyonla değişimi incelenmiştir. Ayrıca numunedeki analit ve matrislerin konsantrasyonları sabit tutulup, matris elementleri değiştirilerek şiddetlendirme etkisinin değişimi araştırılmıştır. Analit olarak La203, matris olarak da Sb, Pr6°ll' Sm2°3' Eu2°3' Gd2°3' Dv2°3' Ho2°3' Tb2°3' Er2°3 ve T1TI2O3 kullanılmıştır. 2 Numuneler, bilinen konsantrasyonlarda 0,066348 g/cm kalınlığında homojen olarak hazırlanmış ve 100 mCi şiddetindeki Am-241 y~`nalka kaynağı ile uyarılmıştır. Numuneden yayımlanan Ka karakteristik x-ışınları Ge(Li) katıhal sayacında sayılmıştır. Sayaçta meydana gelen pulslar ND 66B çok kanallı puis yükseklik analizörünün 2048 kanalında kaydedilmiştir. Sonuçlar üzerinde soğurma, parçacık büyüklüğü ve çalışmanın temelini oluşturan şiddetlendirme etkisine ait düzeltmeler yapılmıştır. Bilinen analit konsantrasyonu ile şiddetlendirme düzeltmesi yapılmadan önceki ve şiddetlendirme düzeltmesi yapıldıktan sonraki analit konsantrasyonları mukayese edilmiştir.
dc.description.abstractSUMMARY In this study, the variation of enhancement effect with concentration has been examined changing the concentrations of analyte and matrix in sample in energy dispersive x-ray fluorescence (EDXRF) analysis. Furthermore the variation of enhancement effect, keeping constant the concentrations of analyte and matrix, changing matrix samples, was investi gated. La2Û3 as an analyte and Sb, Pr6°ll' Sm2°3' Eu2°3' Gd2Û3, Dy203, H02O3, Tb203, E^C^ ve Tm203 as matrixes were used respectively. Samples were prepared at known concentrations and a thickness 2 of 0,066348 g/cm homogeneously and excited by Am-241 y-annular source at an intensity of 100 mCi. Characteristic Ka x-rays which are emitted from the sample were counted by means of Ge (Li) detector. The pulses which are produced in the detector were recorded at 2048 different channels by ND 66B pulse hight analyser. In the results which were found in this study, a correction of absorption, particle size effect and enhancement effect were done. The concentrations of analyte before and after making a correction of enhancement, were compared with a known analyte concentration.en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectFizik ve Fizik Mühendisliğitr_TR
dc.subjectPhysics and Physics Engineeringen_US
dc.titleEnerji dispersiv x-ışını floresans analizinde şiddetlendirme etkisi
dc.typedoctoralThesis
dc.date.updated2018-08-06
dc.contributor.departmentDiğer
dc.subject.ytmEnergy distribution
dc.subject.ytmX ray fluorence analysis
dc.identifier.yokid35125
dc.publisher.instituteFen Bilimleri Enstitüsü
dc.publisher.universityATATÜRK ÜNİVERSİTESİ
dc.identifier.thesisid35125
dc.description.pages65
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess