Show simple item record

dc.contributor.advisorErkılıç, Kuddusi
dc.contributor.authorUlusal, Hatice
dc.date.accessioned2020-12-30T08:13:29Z
dc.date.available2020-12-30T08:13:29Z
dc.date.submitted2005
dc.date.issued2018-08-06
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/495992
dc.description.abstractÖZET Nidek MK-2000 Model Mikrokeratom Kullanarak Miyop Ve Miyopik Astigmat Olgulara Yapılan LASIK Ameliyatlarında Ortalama Flep Kalınlığı ve Buna Etki Eden Faktörlerin Değerlendirilmesi AMAÇ: Nidek MK2000 mikrokeratom modeli ve Nidek EC5000 CX marka excimer laser kullanılarak yapılan LASIK (Laser in situ keratomileusis) olgularında miyop ve miyop astigmatlarda ortalama flep kalınlığının belirlenmesi ve flep kalınlığına etki eden, göze ve mikrokeratoma ait faktörlerin değerlendirilmesi. METODLAR: LASIK uygulanan miyop ve miyop astigmat 82 hastanın 158 gözü çalışma kapsamına alındı. Hastalar kullanılan 130 um ve 160 um'lik keratom başlıklarına göre iki gruba ayrıldı. LASIK işlemi için tüm hastalara Nidek MK2000 mikrokeratom ve Nidek EC 5000 CX excimer laser sistemi kullanıldı. Bütün hastaların preoperatif korneal kalınlık değerinden, flep kaldırıldıktan sonra ölçülen stromal yatak kalınlığı çıkarılarak elde edilen değer, gerçek flep kalınlığı değeri olarak kaydedildi. Hasta yaşı, preoperatif korneal pakimetri, keratometri, viirefraksiyon değerleri ve yanı sıra aynı gün bilateral LASIK geçiren olgularda mikrokeratomun ilk(sağ) ve ikinci(sol) kez kullanımının flep kalınlığına etkileri incelendi. BULGULAR: Sekseniki hastanın 158 gözüne LASIK uygulandı. Altmışdört göze 130 um'lik keratom başlığı kullanılırken, 95 göze 160 um'lik keratom başlığı kullanıldı. Preoperatif sferik ekivelan değeri 130um'lik grupta ortalama -4.2 ± 2.03 D iken löOum'lik grupta ortalama -3.9 ±1.7 D bulundu. Preoperatif korneal pakimetri değerleri 130 um'lik grupta ortalama 523.9 ±34.4 um iken 160 um'lik grupta 556.2 ± 29.4 um bulundu, preoperatif keratometri değerleri ise 130um'lik grupta ortalama Kavg değeri 44.15 ± 1.4 iken 160 um'lik grupta 43.14 ±1.4 bulundu. Ortalama flep kalınlıkları 130 um'lik grupta 87.75 ± 15.8 um iken 160 um'lik grupta 120.8 ± 20.2 fim bulundu. Her iki grupta da ortalama flep kalınlıkları, beklenen flep kalınlığı değerinden istatistiksel olarak anlamlı bir şekilde düşük bulundu ( t=21.349, p<0.001 / 1=18.782, pO.001). Flep kalınlığı ile preoperatif pakimetri arasında pozitif yönde, istatistiksel olarak anlamlı bir ilişki bulunurken, keratometrik değerler ve astigmat değerleri ile negatif yönde bir ilişki tespit edildi. Sağ ve sol gözler arasında flep kalınlığı açısından 130um'lik grupta fark bulunmazken löOum'lik grupta birinci kesimlerin ( sağ göz) ikinci kesimlerden daha kaim olduğu tespit edildi. SONUÇ: Nidek MK 2000 mikrokeratomun her iki keratom başlığında da elde edilen flep kalınlıkları beklenen flep kalınlığı değerinden ince bulundu. Preoperatif korneal kalınlık, korneal keratometrik değerler, astigmat değerleri ve bıçağm ikinci kez kullannmmn elde edilen flep kalınlığına asıl etki eden faktörler olduğu tespit edildi. Anahtar Kelimeler: Flep, keratometre, LASIK, mikrokeratom, pakimetre ve refraksiyon viii
dc.description.abstractSUMMARY The Evaluation Of The Flap Thickness And The Factors Affecting The Flap Thickness İn Myopic And Myopic Astigmatic LASIK Cases Performed By Using Nidek MK 2000 Model Microkeratome Aim : To evaluate the mean flap thickness and the factors affecting the flap thickness in myopic and myopic astigmatic LASIK cases performed by using Nidek MK 2000 Model microkeratome and Nidek EC 5000 CX brand excimer laser. Materials and Methods: One hundred and fifty eight eyes of 82 myopic and myopic astigmatic patients who had LASIK operation were studied. Patients were divided into 2 groups according to microkeratome plate thickness: 130 Jm and 160 pm keratome headings. For LASIK operation, Nidek MK 2000 microkeratom and Nidek EC 5000 CX excimer laser system were used for all patients. The actual flap thickness was calculated by a subtraction method (ie, actual flap thickness = preoperatif corneal thickness - residuel stromal bed thickness). Effects of age, preoperative corneal pacimeter, keratometry and refraction values on flap thickness were studied, also, the effect of the first and the second usage of the microkeratome on flap thickness was studied in cases who underwent bilateral LASIK operation on the same day. Results: LASIK was performed to 158 eyes of 82 patients. 130 ym keratome heading was used in 64 eyes and 160 ym keratome heading in 95 eyes. The mean preoperative spheric equivalant value was -4.2 ± 2.03 D in 130 Jm group and -3,9 ± 1.7 D in 160 Jm group. The mean preoperative corneal pacimeter values were 523.9 ± 34.4 pm in 130 Jim group and 556.2 ± 29.4 ym in 160 ym group. The mean preoperative keratometry (Kavg )values were 44.15 ± 1.4 in 130 ym group and 43.14 ± 1.4 in 160 ym group. The mean flap thicknesses were 87.75 ± 15.8 ym in 130 ym group and 120.8 ± 20.2 ym in 160 ym group. The mean flap thicknesses were significantly lower than the expected flap thickness in both groups ( t= 21.349 p<0.001 / IXt=l 8.782 p<0.001 ). A positive correlation was found between flap thickness and preoperative pakimeter and a negative correlation was found between the flap thickness and keratometric and astigmatic values. Although there was no difference between left and the right eyes flap thickness values in 130 pm group, in 160 Jm group, we found that first flap (in the right eye ) was thicker than the second flap in the left eye. Conclusion: The actual flap thickness was significantly lower than the expected flap thickness by using Nidek MK 2000 microkeratome (plate thickness : 130 and 160 /im). Preoperative central corneal thickness, corneal keratometer values, astigmatic values and the second usage of the microkeratome were the principal factors that influenced flap thickness. Key Words: Flap, keratometry, LASIK, microkeratome, pakimetry, refractionen_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/embargoedAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectGöz Hastalıklarıtr_TR
dc.subjectEye Diseasesen_US
dc.titleNidek MK-2000 model mikrokeratom kullanarak miyop ve miyopik astigmat olgulara yapılan LASIK ameliyatlarında ortalama flep kalınlığı ve buna etki eden faktörlerin değerlendirilmesi
dc.title.alternativeEvaluating the average flap thickness and the factors affection it on myopic and myopic astigmatic LASIK cases performed by using Nidek MK 2000 model microkeratome
dc.typedoctoralThesis
dc.date.updated2018-08-06
dc.contributor.departmentGöz Hastalıkları Anabilim Dalı
dc.identifier.yokid194260
dc.publisher.instituteTıp Fakültesi
dc.publisher.universityERCİYES ÜNİVERSİTESİ
dc.type.submedicineThesis
dc.identifier.thesisid171971
dc.description.pages80
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/embargoedAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/embargoedAccess