Show simple item record

dc.contributor.advisorYavuz Alagöz, Handan
dc.contributor.authorSari Üzek, Esma
dc.date.accessioned2020-12-30T06:34:47Z
dc.date.available2020-12-30T06:34:47Z
dc.date.submitted2017
dc.date.issued2020-01-17
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/474726
dc.description.abstractBu tez çalışması kapsamında Prednisolon (PRD) tayinine yönelik yüzey tanıma bölgelerine sahip moleküler baskılanmış optik sensörler hazırlanmıştır. Çalışma kapsamında kalıp molekül olan prednisolon miktarı değiştirilerek iki fazlı mini-emülsiyon polimerizasyonuyla nanopartiküller hazırlanmış ve yüzey plasmon rezonans sensörün altın çip yüzeyine farklı tekniklerle tutturulmuştur. Hazırlanmış olan üç farklı baskılanmış partikül (PIN1, PIN2 ve PIN3) ve bir tane baskılanmamış partikül (NIN) ilk olarak boyut analiziyle (Zeta-sizer ve STEM) ve yapısal olarak (FTIR ve elementel analiz) karakterize edilmiştir. Çip yüzeyi modifiye edildikten sonra nanosensörler elipsometre ve temas açısı ölçümleri vasıtasıyla karakterize edilmiştir. Kinetik analizler pH 6.6 ve 7.4'de dört sensör içinde gerçekleştirilmiş ve verilere Langmuir, Freundlich, Scathard ve Langmuir-Freundlich izoterm modelleri uygulanmıştır. Kinetik analizler sonucunda pH 6.6'da PIN1, PIN2, PIN3 ve NIN kodlu sensörler için elde edilen tayin limiti sırasıyla 5.1 ppb, 5.5 ppb, 6.9 ppb ve 7.4 ppb iken tayin alt sınırı 16.9 ppb, 18.2 ppb, 23.1 ppb ve 24.2 ppb olarak belirlenmiştir. pH 7.4 belirlenen tayin limiti ise aynı sıralamayla 10.7 ppb, 8.9 ppb, 13.7 ppb ve 12.1 ppb olarak hesaplanırken tayin alt sınırları sırasıyla 35.5 ppb, 29.7 ppb, 45.5 ppb ve 40.2 ppb olarak hesaplanmıştır. Yarışmalı kinetik analizler 17-α-etinil estradiol (EEST) ve estradiol (EST) kullanılarak gerçekleştirilmiştir. pH 6.6'da baskılanmış PIN1, PIN2 ve PIN3 kodlu sensörler baskılanmamış NIN kodlu sensöre göre PRD'yi EEST'den sırasıyla 1.195; 6.500 ve 1.699 kat daha seçici tanırken bu değerler EST için 1.676; 7.857 ve 2.037 kat olarak belirlenmiştir. pH 7.4'de ise bağıl seçicilik katsayıları EEST ve EST için sırasıyla 3.009; 10.556; 2.679 ve 2.758; 14.778; 4.500 kat olarak hesaplanmıştır. Tekrar kullanılabilirlik çalışmaları en iyi sonuçların elde edildiği sensöre uygulanmış ve % 92.8 geri kazanım elde edilmiştir. Doğal örnek olarak vücut sıvılarıyla (idrar ve plazma) çalışılmıştır. Sistemin validasyon çalışmaları yüksek performaslı sıvı kromatografisi (HPLC) ile standart yönteme uygun olarak gerçekleştirilmiştir. Hazırlanan SPR sensörünün HPLC sonuçlarıyla iyi bir uyum içinde olduğu gösterilmiştir.
dc.description.abstractIn this thesis, molecularly imprinted optical sensors with surface recognition regions for prednisolone (PRD) determination have been prepared. Within the scope of this study, nanoparticles were prepared by two-phase mini-emulsion polymerization by changing amount of PRD, which is a template molecule, and the particles were attached to the gold chip surface of the surface plasmon resonance sensor with different techniques. Three differentially imprinted particles (PIN1, PIN2, and PIN3) and one non-imprinted particle (NIN) were first characterized by dimensional analysis (Zeta-sizer and STEM) and then structurally (FTIR and elemental analysis). After the chip surface has been modified with particles, the nanosensors were characterized by means of ellipsometer and contact angle measurements. Kinetic analyzes were performed for four sensors at pH 6.6 and 7.4 and Langmuir, Freundlich, Scathard and Langmuir-Freundlich isotherm models were applied to the data. As a result of the kinetic analyzes, the limit of detection for the PIN1, PIN2, PIN3 and NIN sensors at pH 6.6 were 5.1 ppb, 5.5 ppb, 6.9 ppb and 7.4 ppb, respectively, while the limit of quantifications were determined as 16.9 ppb, 18.2 ppb, 23.1 ppb and 24.2 ppb, respectively. The limit of detection at pH 7.4 was calculated as 10.7 ppb, 8.9 ppb, 13.7 ppb and 12.1 ppb in the same order, and the limit of quantification were calculated as 35.5 ppb, 29.7 ppb, 45.5 ppb and 40.2 ppb, respectively. Competition kinetic assays were performed by using 17-a-ethynyl estradiol (EEST) and estradiol (EST). Imprinted sensors labeled with PIN1, PIN2 and PIN3 codes were selected 1.195; 6.500 and 1.699 times more sensitive to the PRD than EEST when it is compared with non-imprinted NIN-encoded sensor, respectively, and these values were determined as 1.676; 7.857 and 2.037 times for EST at pH 6.6. At pH 7.4, the relative selectivity coefficients were calculated as 3.009; 10.556; 2.679 and 2.758; 14.778; 4.500 times for EEST and EST, respectively. The reusability studies have been applied to the sensor with the best results and 92.8 % recovery is achieved. The method was successfully applied to monitor PRD levels in body fluids (urine and plasma) as a naturel sample. Validation studies of the system were performed according to the standard procedure by high performance liquid chromatography (HPLC). Proposed SPR sensor method was in good agreement with those obtained by HPLC method.en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectBiyokimyatr_TR
dc.subjectBiochemistryen_US
dc.subjectKimyatr_TR
dc.subjectChemistryen_US
dc.titlePrednisolon tayini için yüzey tanıma bölgelerine sahip moleküler baskılanmış sensörlerin geliştirilmesi
dc.title.alternativeDevelopment of molecularly imprinted sensors with surface recognation sites for detection of prednisolone
dc.typedoctoralThesis
dc.date.updated2020-01-17
dc.contributor.departmentKimya Anabilim Dalı
dc.subject.ytmBiosensors
dc.identifier.yokid10135476
dc.publisher.instituteFen Bilimleri Enstitüsü
dc.publisher.universityHACETTEPE ÜNİVERSİTESİ
dc.identifier.thesisid455705
dc.description.pages149
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess