Show simple item record

dc.contributor.advisorCengiz, Kuddusi
dc.contributor.authorDemiray Özen, Feride
dc.date.accessioned2020-12-29T13:51:28Z
dc.date.available2020-12-29T13:51:28Z
dc.date.submitted2009
dc.date.issued2018-08-06
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/434580
dc.description.abstractKardiyovasküler hastalık, böbrek yetmezlikli hastalarda ve böbrek nakli olanlarda en önemli mortalite ve morbidite nedenidir. Bu duruma yol açan faktörlerin belirlenip, aşikar bulgular gelişmeden kardiyak patolojilerin saptanması, zamanında alınacak önlemlerle hastaların yaşam kalitesinde ve süresinde uzamaya neden olacaktır. Bu amaçla hemodiyaliz (HD), böbrek nakli yapılan transplantasyon (Tx) ve rejeksiyon (Rx) hastalarında ekokardiyografi ve 24 saatlik kan basıncı monitorizasyonu (AKBM) ile yapılan ölçüm sonuçları karşılaştırıldıÇalışmaya; 23 hemodiyaliz, 28 transplantasyon, 32 rejeksiyon ve 30 kontrol olmak üzere toplam 113 hasta dahil edildi. Çalışmaya alınan hastaların kalp fonksiyonları, konvansiyonel ekokardiyografik ölçümler yanında doppler ve doku doppler yöntemiyle değerlendirildi. Dört grup arasında ejeksiyon fraksiyonu açısından anlamlı bir fark saptanmadı (p>0,05). HD grubunun %60' ında, Tx grubunun %48' inde, Rx hastasının %50' sinde ve kontrol grubunun %4' ünde LVH saptandı. Ortalama E' dalga hızına göre; HD grubunun %58' inde, Tx grubunun %50' sinde, Rx grubunun %52' sinde, kontrol grubundaki hastaların ise %4,3' ünde diyastolik disfonksiyon tespit edildi. Diyastolik disfonksiyon açısından HD, Tx ve Rx grupları arasında anlamlı fark saptanmadı (p>0,05). Üç grup (HD, Tx ,Rx) kontrol grubu ile karşılaştırıldığında diyastolik disfonksiyon açısından anlamlı fark mevcuttu (p<0,05). Doku doppler E/E' oranı açısından dört grup arasında anlamlı fark tespit edilmedi (p>0,05Çalışmaya alınan hastaların ambulatuar kan basıncı monitorizasyonu ölçümleri karşılaştırıldı. HD hastalarının %69,6' sı, Tx hastalarının %66' sı, Rx hastalarının %70,8' i, kontrol grubunun %13,3' ü non-dipper .paterne sahiptiler. Böbrek nakli yapılan hastalarda, gece kan basıncı yükünün, LVMI üzerindeki etkisini belirlemek amacıyla dipper ve non-dipper olan böbrek nakil hastaları sol ventrikül kitle indeksi, yaş, cinsiyet, diyaliz süresi açısından karşılaştırıldı. LVMI açısından non-dipper grupta, dipper gruba göre anlamlı fark saptandı (p<0,05). Yaş, cinsiyet, diyaliz süresi açısından dipper ve non- dipper grup arasında anlamlı fark saptanmadı (p>0,05Sistolik ve diyastolik disfonksiyon etyolojisinde rol oynayan hipertansiyon ve ateroskleroz hem kronik böbrek hastalarını hemde böbrek nakil hastalarını etkilemektedir. Kardiyovasküler risk profili olarak birbirlerine oldukça benzeyen hemodiyaliz ve böbrek nakli gruplarında ekokardiyografik ölçümleri ve ambulatuar kan basıncı monitorizasyonu sonuçlarını araştıran bu çalışma, HD ve böbrek nakli grubunun sistolik ve diyastolik disfonksiyon, kan basıncı ölçümleri ve kan basıncının gece-gündüz gösterdiği değişkenlikler açısından birbirlerine benzediğini ve normal sağlıklı erişkinlerden farklı olduklarını ortaya koymuştur.
dc.description.abstractCardiovascular disease (CVD) is the most important cause of the mortality and morbidity in the patients with kidney failure and in those who underwent kidney transplantation. The quality and span of life of the patients might be enhanced by finding out the causative factors, determining the cardiologic pathologies before the emergence of some apparent symptoms and taking the timely precautions. For this purpose, investigated echocardiographic measuremets and the results of ambulatory blood pressure (AKBM) in HD and renal transplantation (Tx) and rejection (Rx) patientsHD, Tx and rejection respectively 113 patients (23 HD, 28 transplantation, 32 rejection, 30 control group) were included in the study. Heart functions of the patients included in the study were assessed via tissue doppler echocardiography method as well as conventional measurements. No significant differrence was detected between 4 groups in terms of the ejection fraction (p>0,05). Left ventricular hypertrophy was detected 60% of the HD groups, 48% of the Tx groups, 50% of the Rx groups and 4% of the control group had. 62% of the HD groups, 50% of the Tx groups, 52% of the Rx groups and 4,3% of the control groups had diastolic disfunction of the average E? wave velocity. No significant difference was detected between HD, Tx and Rx groups in terms of diastolic disfunction (p>0,05). A significant difference was observed between the control group and HD, Tx, Rx group with respect to diastolic functions in this methods (p<0,05). No significant difference was detected between four groups in terms of the ratio of tissue doppler E/E? (p>0,05All the patients underwent an ambulatory blood pressure monitoring for 24 hours. The measurements of ambulatory blood pressure monitoring of the patients included in the study were compared. 69,6 % of the HD patients, 66 % of Tx patients, 70,8 % of Rx patients and 13,3 % control group had non- dipper pattern. Except for the control group, no significante was detected in the other 3 groups in terms of the measurements the blood pressure. The Tx and Rx patients with dipper and non-dipper profile were compared in terms of LVMI (Left ventricular mass index), age, gender, duration of dialysis and the values of haemoglobin in order to detect the effect of the load of the blood pressure during the night on LVMI in Tx and Rx patients. No significant difference was detected with respect to age, gender, duration of dialysis and the values of haemoglobin (p>0,05). There was a significant difference in non-dipper group with respect to LMVI in comparison with dipper group (p<0,05Hypertension and atherosclerosis which play a part in the aetology of the systolic and diastolic disfunction afflicts both the chronic kidney patients and the transplantation patients. This research which investigates echocardiographic measuremets and the results of ambulatory blood pressure in HD and renal transplantation patients resemble each other in systolic and diastolic dysfunction changes in the measurements of blood pressure during the day and night and they are different from normal healthy adults.en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/embargoedAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectNefrolojitr_TR
dc.subjectNephrologyen_US
dc.titleHemodiyaliz ve böbrek nakli yapılan hastalarda doku doppler ekokardiyografi ve 24 saatlik ayaktan kan basıncı monitörizasyonu ölçümlerinin değerlendirilmesi
dc.title.alternativeİnvestigated tissue doppler echocardiographic measurements and the results of 24 hours ambulatory blood pressure in haemodialysis and renal transplantation patients
dc.typedoctoralThesis
dc.date.updated2018-08-06
dc.contributor.departmentİç Hastalıkları Anabilim Dalı
dc.subject.ytmKidney diseases
dc.subject.ytmKidney transplantation
dc.subject.ytmKidney failure-chronic
dc.subject.ytmRenal dialysis
dc.subject.ytmEchocardiography-doppler
dc.subject.ytmEchocardiography
dc.subject.ytmBlood pressure determination
dc.subject.ytmBlood pressure monitors
dc.subject.ytmBlood pressure
dc.identifier.yokid345901
dc.publisher.instituteTıp Fakültesi
dc.publisher.universityONDOKUZ MAYIS ÜNİVERSİTESİ
dc.type.submedicineThesis
dc.identifier.thesisid236496
dc.description.pages65
dc.publisher.disciplineNefroloji Bilim Dalı


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/embargoedAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/embargoedAccess