Show simple item record

dc.contributor.advisorÇehreli, Zafer Cavit
dc.contributor.authorArslan, Ezgihan
dc.date.accessioned2020-12-29T13:42:01Z
dc.date.available2020-12-29T13:42:01Z
dc.date.submitted2016
dc.date.issued2018-08-06
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/431440
dc.description.abstractBu çalışma, bulk-fill yapıdaki farklı kompozit rezinlerin sınıf 1 kavitelerdeki sızdırmazlık performanslarının in vitro koşullarda değerlendirilmesi amacıyla yürütülmüştür. Çekilmiş çürüksüz 168 adet insan 3. azı dişi, kullanılan dolgu materyali/adeziv uygulama moduna göre 14 alt gruba (n=12) rastgele ayrılmıştır: Grup 1: Minede ön asitleme (ÖA) + FL-BOND II + Beautifil Bulk fill Restorative 2X2 mm inkrement; Grup 2: ÖA + FL-BOND II + Beautifil Bulk fill Restorative 4 mm tek inkrement; Grup 3: ÖA + FL-BOND II + Beautifil Bulk fill Flowable 2X2 mm inkrement; Grup 4: ÖA + FL-BOND II + Beautifil Bulk fill Flowable 4 mm tek inkrement; Grup 5: ÖA + Single Bond Universal (SBU)+Filtek Bulk Fill Posterior 2X2 mm inkrement; Grup 6: ÖA + SBU + Filtek Bulk Fill Posterior 4 mm tek inkrement; Grup 7: ÖA + SBU + Filtek Bulk Fill Flowable 2X2 mm inkrement; Grup 8: ÖA+ SBU+ Filtek Bulk Fill Flowable 4 mm tek inkrement; Grup 9: ÖA + Adhese Universal Vivapen (AU) + Tetric Evo Ceram Bulk Fill 2X2 mm inkrement; Grup 10: ÖA + AU + Tetric Evo Ceram Bulk Fill 4 mm tek inkrement; Grup 11: ÖA + AU + Tetric Evo Flow Bulk Fill Flowable 2X2 mm inkrement; Grup 12: ÖA + AU + Tetric Evo Flow Bulk Fill Flowable 4 mm tek inkrement; Grup 13: ÖA + SBU + Z550 2X2mm inkrement; Grup 14: ÖA + SBU + Z550 4 mm tek inkrement. Örnekler 1000 devir termosiklusa tabi tutulduktan sonra, %0,5'lik bazik fuksin solüsyon ile boya penetrasyon testi gerçekleştirilmiştir. Diş kesitlerinden alınan dijital görüntüler üzerinde görüntü analizi ile kantitatif olarak belirlenen mikrosızıntı düzeyleri, Tek yönlü varyans analizi ve Tukey testleri ile istatistiksel olarak karşılaştırılmıştır (p=0.05). Kütlesel teknikle uygulanan örnekler, tabakalama tekniği ile uygulanan örneklere kıyasla anlamlı düzeyde yüksek sızıntı göstermişlerdir (p<0.05). Akışkan kompozitlerin uygulandığı gruplar da anlamlı düzeyde yüksek mikrosızıntı göstermiştir (p<0.05). Tüm gruplar içinde en fazla sızıntı düzeyi Grup 3 ve Grup 4'te izlenmiştir (p<0.05).
dc.description.abstractThis in vitro study was conducted to evaluate the sealing effectiveness of different bulk fill composite resins in class I cavities. Extracted human third molars (n=168) were randomly allocated into 14 experimental groups (n=12/group) with respect to the composite resin/adhesive system employed: Group 1: Phosphoric acid ethcing of enamel (PE) + FL-BOND II + Beautifil Bulk fill Restorative 2X2mm increment; Group 2: PE + FL-BOND II + Beautifil Bulk fill Restorative 4 mm single increment; Group 3: PE + FL-BOND II + Beautifil Bulk fill Flowable 2X2mm increment; Group 4: PE + FL-BOND II + Beautifil Bulk fill Flowable 4 mm single increment; Group 5: PE + Single Bond Universal (SBU) + Filtek Bulk Fill Posterior 2X2mm increment; Group 6: PE + SBU + Filtek Bulk Fill Posterior 4 mm single increment; Group 7: PE + SBU + Filtek Bulk Fill Flowable 2X2mm increment; Group 8: PE + SBU + Filtek Bulk Fill Flowable 4 mm single increment; Group 9: PE + Adhese Universal Vivapen (AU) + Tetric Evo Ceram Bulk Fill 2X2mm increment; Group 10: PE + AU + Tetric Evo Ceram Bulk Fill 4 mm single increment; Group 11: PE + AU + Tetric Evo Flow Bulk Fill Flowable 2X2mm increment; Group 12: PE + AU + Tetric Evo Flow Bulk Fill Flowable 4 mm single increment. Group 13: PE + SBU + Z550 2X2mm increment; Group 14: PE + SBU + Z550 4 mm single increment. Specimens were subjected to 1000X thermocycling, and thereafter to 0.5% basic fuchsin dye penetration test. The extent of microleakage was measured quantitatively using image analysis on sections of specimens. One-way ANOVA and Tukey tests were used for statistical analysis of the data (p=0.05). Single increment application of the tested composites resulted in significantly greater leakage values compared with their layered counterparts (p<0.05). Flowable bulk-fill composites showed significantly greater leakage values (p<0.05). The maximum amount of microleakage was observed in groups 3 and 4 (p<0.05).en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectDiş Hekimliğitr_TR
dc.subjectDentistryen_US
dc.titleKütlesel veya tabakalı formda uygulanan bulk-fıll kompozitlerin sızdırmazlık performanslarının in vitro koşullarda incelenmesi
dc.title.alternativeInvitro conditions of the sealing performance of bulk-fill composites applied in the glass or layered form
dc.typedoctoralThesis
dc.date.updated2018-08-06
dc.contributor.departmentÇocuk Diş Hekimliği Anabilim Dalı
dc.subject.ytmDental restoration
dc.subject.ytmDental leakage
dc.subject.ytmDental materials
dc.subject.ytmComposite resins
dc.subject.ytmComposite materials
dc.identifier.yokid10131539
dc.publisher.instituteDiş Hekimliği Fakültesi
dc.publisher.universityHACETTEPE ÜNİVERSİTESİ
dc.type.subdentistThesis
dc.identifier.thesisid443889
dc.description.pages96
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess