Show simple item record

dc.contributor.advisorCebeci, Mehmet
dc.contributor.authorGençoğlu, Muhsin Tunay
dc.date.accessioned2020-12-29T13:13:06Z
dc.date.available2020-12-29T13:13:06Z
dc.date.submitted1997
dc.date.issued2018-08-06
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/421430
dc.description.abstractm ÖZET Yüksek Lisans Tezi YÜKSEK GERİLİM İZOLATÖRLERİNİN KİRLENME ATLAMA DAVRANIŞLARININ SONLU ELEMANLAR YÖNTEMİ YARDIMIYLA BELİRLENMESİ Muhsin Tunay GENÇOĞLU Fırat Üniversitesi Fen Bilimleri Enstitüsü Elektrik-Elektronik Mühendisliği Anabilim Dalı 1997, Sayfa: 81 Yüksek gerilim izolatörlerinin, enerji iletim sistemlerinde sürekli ve emniyetli bir yalıtım sağlaması istenir. Ancak izolatörlerin yüzeyinde oluşan kir tabakası, izolatörlerden beklenen performansı ve görevleri olumsuz yönde etkileyerek yüzeysel atlamalara ve dolayısıyla kısa devre arızalarına neden olur. Bu durum, enerji iletim problemlerinin en önemlilerinden biridir. Kirli bölgelerde kullanılacak izolatörlerin yüzeysel atlama performansını belirlemek üzere birçok tabii ve suni test yöntemleri geliştirilmiştir. Ayrıca modeller üzerinde analitik hesaplamalar yapılmıştır. İzolatör yüzeyinde oluşan kir tabakası, AR modeli ile temsil edilebilir. Bu model, izolatör yüzeyini sızma uzunluğu boyunca açarak bir düzlem haline getiren gerçek modeldir. İzolatörün yüzeysel atlama performansını belirleyen arka seri kir direncinin hesabı, modeller üzerinde ve bilgisayar yöntemleri kullanılarak yapılabilir. Bu çalışmada kirlenme atlamasının önemi, tanıtımı ve fiziksel mekanizması açıklanarak izolatörlerin atlama davranışlarının tabii ve suni testler yoluyla nasıl belirlendiği ve izolatör eşdeğer modelleri karşılaştırmalı olarak incelenmiştir. Ele alınan 5 tip izolatörün arka seri direnç değişimlerini hesaplamak üzere önce izolatörlerin AR modelleri ayrı ayrı bulunmuş ve bu modellere SEY uygulanarak direnç değişimleri bilgisayar yardımıyla hesaplanmıştır. Hesaplanan sonuçlar deneysel sonuçlarla karşılaştırılmıştır. ANAHTAR KELİMELER: İzolatör, Sonlu Elemanlar Yöntemi, AR modeli, Kirlenme atlaması, Kir direnci.
dc.description.abstractIV SUMMARY Master Thesis Determination of Pollution Flashover Behaviour of High Voltage Insulators by The Finite Element Method Muhsin Tunay GENÇO?LU Fırat University Graduate School of Natural and Applied Sciences Department of Electrical and Electronics Engineering 1997, Page: 81 High voltage insulators are supposed to provide a continuous and safety insulation in energy transmission systems. However, pollution layer that occurs on the surface of insulator, decreases the performance of insulators and causes surface flashovers and therefore short circuit failures. Several natural and artificial test methods had been developed to determine the surface flashover performance of the insulators, which will be used in polluted region. In addition, analytical calculations have been carried out on the models. AR model can be used to model the surface pollution layer of the insulator. AR model is a real model that open the surface of the insulator along the leakage length to a plane. Calculation of the pollution resistance serial to the discharge which determines the surface flashover performance can be carried out on the models and using computer methods. In this work, pollution flashover and physical mechanism of it have been defined and its importance has been explained. Determination of the flashover behaviour of the insulators via natural and artificial tests and insulator equivalent models have been examined, comparatively. In order to calculate the variation of the resistance serial to the flashover, AR models of the insulators has been constructed seperately for 5 insulators that has been examined and later their resistance variations have been calculated applying FKM analysis to the models. Computational results are compared with the experimental results. Key Words: Insulator, Finite Element Method, AR model, Pollution flashover, Pollution resistance.en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectElektrik ve Elektronik Mühendisliğitr_TR
dc.subjectElectrical and Electronics Engineeringen_US
dc.titleYüksek gerilim izolatörlerinin kirlenme atlama davranışlarının sonlu elemanlar yöntemi yardımıyla belirlenmesi
dc.title.alternativeDetermination of pollution flashover behaviour of high voltage insulators by the finite element method
dc.typemasterThesis
dc.date.updated2018-08-06
dc.contributor.departmentElektrik-Elektronik Mühendisliği Anabilim Dalı
dc.subject.ytmPollution
dc.subject.ytmInsulating materials
dc.subject.ytmHigh voltage
dc.subject.ytmFinite element method
dc.identifier.yokid65868
dc.publisher.instituteFen Bilimleri Enstitüsü
dc.publisher.universityFIRAT ÜNİVERSİTESİ
dc.identifier.thesisid65868
dc.description.pages81
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess