dc.description.abstract | ISTANBUL BİNALARINDA KAROT YARDIMIYLA BETON NİTELİK DENETİMİ Burcu AKÇAY Anahtar Kelimeler: Beton Karodan, Yerinde Deneyler, Beton Kalitesi, istanbul Binaları. Özet: Ağustos 1999 Gölcük depreminde önemli ölçülerde can ve mal kaybına neden olan betonarme yapılardaki hasar sonrası, birinci dereceden deprem bölgesi olan İstanbul İli ve çevresindeki yapılarda beton dayanımının belirlenmesine gerek duyulmuştur. Bu amaçla, İMO İstanbul Şubesi Beton Araştırma ve Geliştirme Laboratuvanndan, yapım zamanı, kat sayısı beton kaynağı ve projedeki beton sınıfı bilinen 511 binadan alınan karotlar üzerinde basınç deneyleri uygulanmıştır. Yapılan istatistik değerlendirmeler, 511 binadan alınan karotlarm 1,88 ile 52,00 N/mm2 arasında değişen eşdeğer küp karakteristik basınç dayanımlarına sahip olduğunu göstermektedir. Bu dayanımların ortalama ve standart sapma değerleri sırasıyla 16,54 N/mm2 ve 8,314 olarak bulunmuştur. İstatistik sonuçların beton kaynağı (yerinde dökme, santral ve hazır beton) ve sınıfına (BS14, BS16, BS18, BS20, BS25, BS30) göre yapılan değerlendirmeler, yerinde dökme betonun BS18 beton dayanım koşullarım sağlayamadığım göstermektedir. Karotlarm basınç dayanım deney sonuçlarının ortalama değerlere göre hesaplandığında yerinde dökme betonun %77'si, karakteristik dayanımlara göre hesaplandığında ise %91'i BS14 beton sınıfının basınç dayanımının altında kalmıştır. Tahribatlı metot olarak bilinen karot alımıyla yerinde beton dayanımının tayininin yapı elemanına verdiği zarar düzeyinin belirlenmesi için yapılan deneysel çalışmada farklı üç dayanımda referans, karot alınmış ve karot deliği rötresiz tamir harcıyla doldurulmuş küp numunelere basınç deneyi uygulanmıştır. Bunun sonucunda, betonda gerekli dayanımın elde edilebilmesi için karot deliklerinin doldurulması gerektiği görülmüştür. Ayrıca, karot deliklerinin, rötresiz tamir betonuyla doldurulması ile, düşük dayanımlı betonlarda %100 ve yüksek dayanımlı betonlarda %93 lük basınç dayammı elde edildiği bulunmuştur. | |
dc.description.abstract | TESTING FOR CONCRETE QUALITY IN ISTANBUL BUILDINGS BY CORE SAMPLES Burcu AKÇAY Keywords: Concrete Cores, In-situ Tests, Concrete Quality, Istanbul Buildings. Abstract: The most devastating cause of the August 1999 Gölcük earthquake was obviously the measure of damage occurred in reinforced concrete structures. An attempt has, therefore, been made to document the strength and quality of concrete material used to built the various types of buildings (including houses, governmental and industrial buildings) around the city of Istanbul, located in the first-degree dangerous area for a potential earthquake risk. In this respect, the concrete core samples, collected by the research and development laboratories of the Istanbul branch of Chamber of Civil Engineers, have been tested for their compressive strength. Sample collection applied to a total of 551 buildings, of which the construction details such as the dates for construction, number of storeys, the source and class of the concrete material are known. As a result of the statistical analyses of the collected data, it has been found that the tested core samples from 511 buildings have equivalent cube characteristics of between 1.88 and 52.00 N/mm2. The mean and standard deviation of these characteristic strength values have been found to be 16.54 N/mm2 and 8.314 respectively. The statistical results calculated using the source (e.g., cast in place and ready mixed) and class (e.g., C14, C16, C18,C20, C25 and C30) of concrete material indicate that the cast in place concrete is, in general, quite far away from meeting the strength quality of C18 concrete. The results gathered using the mean values show that approximately 77% of cast in place concrete is below the quality required for C14 concrete. This ratio increases to be about 91% when the equivalent cube characteristics are considered. In addition to the statistical analyses, another analyses method, known as 'the destructive method' applied to examine the destruction formed in the members of structures by core sampling. For this purpose, compressive strength of three different types of concrete cube samples (with and without core sampled and filled samples) has been determined. As a result, it has been shown that it was necessary to fill the cored holes to receive the level of quality required. It has also been documented that filling the holes with a non-shrink repairing mixture gives a strength of about 100% of the original strength of low quality concrete and a strength of 93% of the original strength of high quality concrete. 11 | en_US |
dc.language | Turkish | |
dc.language.iso | tr | |
dc.rights | info:eu-repo/semantics/embargoedAccess | |
dc.rights | Attribution 4.0 United States | tr_TR |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject | İnşaat Mühendisliği | tr_TR |
dc.subject | Civil Engineering | en_US |
dc.title | İstanbul binalarında karot yardımıyla beton nitelik tayini | |
dc.title.alternative | Testing concrete quality using core samplaes in İstanbul buildings | |
dc.type | masterThesis | |
dc.date.updated | 2018-08-06 | |
dc.contributor.department | Diğer | |
dc.subject.ytm | Cores | |
dc.subject.ytm | Buildings | |
dc.subject.ytm | Istanbul | |
dc.subject.ytm | Earthquake | |
dc.subject.ytm | Concrete strength | |
dc.identifier.yokid | 100012 | |
dc.publisher.institute | Fen Bilimleri Enstitüsü | |
dc.publisher.university | KOCAELİ ÜNİVERSİTESİ | |
dc.identifier.thesisid | 96828 | |
dc.description.pages | 189 | |
dc.publisher.discipline | Diğer | |