Show simple item record

dc.contributor.advisorBağcı, Cahit
dc.contributor.authorCengiz, Beyhan
dc.date.accessioned2020-12-29T13:01:11Z
dc.date.available2020-12-29T13:01:11Z
dc.date.submitted2002
dc.date.issued2018-08-06
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/417677
dc.description.abstractKURŞUNA MARUZ KALAN İŞÇİLERDE BAZI HEMATOLOJİK PARAMETRELER VE ELEKTROKARDİYOGRAFİ BULGULAR Araş. Gör. Beyhan CENGİZ Yüksek Lisans Tezi Gaziantep Üniversitesi Sağlık Bilimleri Enstitütüsü, Fizyoloji Anabilim Dalı Tez Yöneticisi: Prof. Dr. Cahit BAĞCI Şubat-2002, 34 sayfa ÖZET Kurşuna maruz kalmanın kan parametreleri ile kalp damar sistemi üzerine etkilerinin araştırılması. Bu çalışma; 26 kontrol, 34 egzoz tamircisi ve 20 akü sanayisinde çalışmakta olan toplam 80 erkek birey üzerinde yapılmıştır. Çalışmada öncelikle bireylerin anamnezleri alındı, kan basınçları (Riester marka, Germany) tansiyon aleti ile ölçüldü. Elektrokardiyografileri (Kenz marka Japan) elektrokardiyografi aleti ile 25 mm/sn hıza ve 10 mV/mm genliği ayarlanarak alındı. İki tüp kan alındı. Alınan kanlardan bir tanesiyle kan hücreleri sayımı (Coulter Gen S System 2, Germany) yapıldı. Diğer tüp içindeki kan atomik, absorpsiyon spektrofotometre ile kan kurşun seviyeleri (UNICAM 939 AA, England) ölçüldü. Kan kurşun düzeyleri kontrol grubunda 14,60 ± 2,6 ı^g/dl, egzoz tamircilerinde 26,49 ± 9,4 jıg/dl, akü işçilerinde 36,91 ± 2.6 pıg/dl ve P değeri 0,001 'dir. Hemotokrit değer kontroi grubunda %44.78 ± 3,05, egzoz tamircilerinde %45,70 ±3,54, akü işçilerinde %42,56 ± 3,86 ve P değeri 0,008 bulunmuştur. Hemoglobin miktarı kontrol grubunda 14,97 + 1,14 gr/dl,egzoz tamircilerinde 15,09 ± 0,95 gr/dl, akü işçilerinde 13,78 ± 1,57 gr/dl ve P değeri 0,001 'dir. MCHC kontrol grubunda 33,45 ± 0,63 gr/dl, egzoz tamircilerinde 33,08 ± 1,23 gr/dl, akü işçilerinde 32,34 ± 1,69 gr/dl ve P değeri 0,012'dir. MCH kontrol grubunda 29,47 ± 1,46 pg, egzoz tamircilerinde 29,15 ± 1,23 pg, akü işçilerinde 28,11 ±2,34 pg ve P değeri 0,019'dur. RDW miktarı kontrol grubu %13,01 ± 0,85, egzoz tamircileri %13,46 ± 0,59, akü işçileri %14,80 ±1,64 ve P değeri 0,001 'dir. Sistolik kan basıncı kontrol grubu 129,78 ± 5,02 mmHg, egzoz tamircilerinde 134,35 ± 4,56 mmHg, akü işçilerinde 137,30 ± 17,65 mmHg ve P değeri 0,239'dur. Diastolik kan basıncı kontrol grubu 71,42 ± 1,83 mmHg, egzoz tamircilerinde 70,29 ± 8,78 mmHg, akü işçilerinde 73,29 ± 11,91 mmHg ve P değeri 0,386'dır. Elektrokardiografi sonuçlarına bakıldığında, kontrol grubunda R-R aralığı 0,85 ± 0,15 sn, P-R aralığı 0,12 ± 0,019 sn, QT aralığı 0,35 ± 0,027 sn, QTc intervalinde 0,38 ± 0,029 sn, egzoz tamircilerinde R-R aralığı 0,81 ± 0,14 sn, P-R aralığı 0,12 ± 0,020 sn, QT aralığı 0,37 ± 0,048 sn, QTc intervali 0,41 ± 0,055 sn, akü işçilerinde R-R aralığı 0,93 ± 0,37 sn, P-R aralığında 0,13 ± 0,020 sn, QT aralığı 0,35 ± 0,021 sn ve QTc intervali 0,39 ± 0,031 sn değerleri bulunmuştur. Çalışma sonunda kan kurşun seviyesi ile hemotolojik bulgular arasından ilişki olduğu tesbit edilmiştir. Kan basıncı istatistiksel açıdan anlamlı olmamakla beraber matematiksel olarak küçük bir artış gözlenmektedir. Elektrokardiyografik açıdan kan kurşunu ile QTC açısında bir uzama olduğu ve bunun da istatistiksel açıdan anlamı olduğu gözlenmiştir. Anahtar Kelimeler: kurşun, kan, kan basıncı, elektrokardiyografi
dc.description.abstractTHE EFFECTS OF INDUSTRIAL LEAD ON CERTAIN HEMATOALOGICAL AND ELECTROCARDIOGRAPHICAL PARAMETERS IN WORKERS. Res. Asist. Beyhan CENGİZ M.S. Thesis Gaziantep University Graduate School of Health Sciences, Department of Physiology Supervisor: Prof. Dr. Cahit BA?CI February - 2002, 34 Pages ABSTRACT To determine the effect of industrial lead exposure on cardiovascular system and hematological parameters. This study was performed on a total of 80 workers, 34 workers in exhaust repair, 20 workers in battery industry and 26 control workers. Medical history, blood pressure, electrocardiogram, and blood count and blood lead levels were examined in all individuals. For medical history standard set of questions were asked to the individuals. Blood pressure measurements were done by the same sphygmomanometer (Riester, Germany) on right arm while sitting position. Electrocardiogram (EKG) was recorded by portable EKG device (Kenz, JAPAN), the speed was set on 25 mm/second and 10 mV/mm. Complete blood count was studied by autoanalizer (Coulter Gen S System 2, Germany). Blood lead levels were measured by atomic absorption spectrophotometer (UNICAM 939 AA, England). Standard solution for lead was prepared for before the measurements and spectrophotometer was set on wavelength 283.3 for blood lead level measurement. Mean blood lead levels were 14.6+ 2.6 fig/dl in controls, 26.49+9.4 jLLg/dl in exhaust workers, 36.91+ 2.6 (.ig/dl in battery industry workers. The difference among the groups was statistically significant (p<0.001 ).Blood hematocrit contents were 44.78+ 3.05, 45.7+ 3.54, 42.56+ 3.86 respectively in controls, exhaust workers and in battery workers (p=.008). Blood hemoglobin levels were 14.97+ 1.14, 15.09+ 0.95 and 13.78+ 1.14 respectively (p=0.001). The other blood parameter MCHC were measured as 33.45+ 0.63 in control, 33.08+J.23 in exhaust workers and 32.34+ 1.69 in battery workers (p=0.012). MCH were 29.47+ 1.46, 29.15+ 1.23 and 28.11 + 2.34 respectively within the groups (p=0.019). RDW were 13.01+ 0.85 in controls, 13.46+ 0.59 in exhaust workers and 14.80+ 1.64 in battery workers (pO.001). Systolic and diastolic blood pressures were not different among the groups. The systolic blood pressures were 129+ 5.02 in controls, 134.35+ 4.56 in exhaust workers and 137.30+ 17.56 in battery workers (p=0.239) and diastolic blood pressure were 71.42+ 1.83, 70.29+ 8.78 and 73.29+ 11.91 respectively (p=0.386). Electrocardiographic (ECG) analysis of the groups lead us the following findings. Control group mean ECG results were 0.85+JD.15 of R-R interval, 0.12+0.019 P-R interval, 0.35+ 0.027 of QT interval and 0.38+ 0.029 of QTcjnterval. The same intervals for the exhaust workers were 0.81 + 0.14 of R-R, 0.12+_0.020 of P-R, 0.37+_0.048 of QT, and 0.41+_0.055 QTc. For the battery workers, the same ECG parameters were 0.93 + 0.37 for R- R, 0.13+.0.020 for P-R, 0.35+_0.021 for QT and 0.39+0.031 - Industrial lead exposure causes high blood levels of lead and it effects blood parameters in individuals in Gaziantep area. Better precautions should be taken for the workers dealing with lead. Key words: Lead, Blood pressure, Electrocardiography, blooden_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/embargoedAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectFizyolojitr_TR
dc.subjectPhysiologyen_US
dc.subjectHematolojitr_TR
dc.subjectHematologyen_US
dc.subjectKardiyolojitr_TR
dc.subjectCardiologyen_US
dc.titleKurşuna maruz kalan işçilerde bazı hematolojik parametreler ve elektrokardiyografik bulgular
dc.title.alternativeThe Effects of industrial lead on certain hemetological and electrocardioraphical parameters in workers
dc.typemasterThesis
dc.date.updated2018-08-06
dc.contributor.departmentFizyoloji Anabilim Dalı
dc.identifier.yokid115514
dc.publisher.instituteSağlık Bilimleri Enstitüsü
dc.publisher.universityGAZİANTEP ÜNİVERSİTESİ
dc.identifier.thesisid115051
dc.description.pages34
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/embargoedAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/embargoedAccess