Show simple item record

dc.contributor.advisorÖzel, Haluk Emre
dc.contributor.authorGüder, Gizem
dc.date.accessioned2020-12-29T12:15:49Z
dc.date.available2020-12-29T12:15:49Z
dc.date.submitted2016
dc.date.issued2019-03-07
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/410208
dc.description.abstractBu çalışma, Er:YAG lazer veya frez ile hazırlanmış kavitelerde adeziv sistem-dentin bağlantısının in vitro olarak mikrosızıntı açısından değerlendirilmesi amacıyla yapılmıştır. Mikrosızıntı ve SEM analizleri için çürüksüz ve restorasyonsuz 40 daimi insan premolar dişi üzerinde mine ve dentin yüzey hazırlığı Er:YAG lazer (minede 400 mJ/20 Hz; dentinde 200 mJ/20 Hz) veya aeratöre takılan elmas frezler ile oluşturulmuş örnekler rastgele 8 gruba ayrılmıştır: 1.Grup: Frez + Clearfil SE Bond (Kuraray); 2.Grup: Er:YAG lazer (Syneron Dental Lasers) + Clearfil SE Bond; 3.Grup: Frez + Single Bond Universal (3M ESPE); 4.Grup: Er:YAG lazer + Single Bond Universal; 5.Grup: Frez + OptiBond All-in-One (Kerr); 6.Grup: Er:YAG lazer + OptiBond All-in-One; 7.Grup: Frez + Asit + Adper Single Bond 2 (3M ESPE); 8.Grup: Er:YAG Lazer + Asit + Adper Single Bond 2. Örnekler 5ºC ve 55ºC arasında 1000 termal siklus gerçekleştirmiş ve 24 saat %0,5 bazik fuksinde bekletilmiştir. Longitudinal kesit alınmış sınıf V kavitelerdeki adeziv sistem-dentin ara yüzeyinde boya penetrasyonu, ışık mikroskobu altında iki gözlemci tarafından önceden hazırlanmış skor tablosuna göre değerlendirilmiştir. SEM analizi ile adeziv sistem-dentin ara yüzeyleri ve hibrit tabakanın yapısı incelenmiştir. Gruplarda elde edilen mikrosızıntı değerleri, Mann Whitney U Testi, Kruskal Wallis tek yönlü varyans analizi ve Dunn's Post Hoc Testi ile istatistiksel olarak değerlendirilmiştir. Kavite hazırlık yönteminin grupların mikrosızıntı değerleri arasında istatistiksel olarak anlamlı bir fark oluşturmadığı tespit edilmiştir (p>0,05). Asit ile pürüzlendirme işlemini takiben uygulanan bir total-etch adeziv olan Adper Single Bond 2, çalışmamızda servikal yüzeylerde en fazla mikrosızıntının görüldüğü adeziv sistem olmuştur. Self-etch adezivler bağlanma ve mikrosızıntı açısından daha başarılı bulunmuştur. Servikal yüzeylerdeki mikrosızıntı düzeyleri arasındaki fark istatistiksel olarak anlamlı bulunmuştur (p<0,001). OptiBond All-in-One self-etch adeziv sistemi servikal yüzeylerde en az mikrosızıntıya yol açmıştır. Sonuç olarak, elde edilen bulgularda Er:YAG lazerin geleneksel yönteme alternatif bir kavite hazırlama yöntemi olarak kullanılabileceği, ancak lazer ile hazırlanan dentin yüzeylerinde optimal adeziv bağlanmanın sağlanabilmesi için gelecek araştırmalara gereksinim olduğu belirlenmiştir.
dc.description.abstractThe aim of this study was to assess the adhesive systems/dentin interfaces on Er:YAG laser and bur prepared cavities by in-vitro study of microleakage and SEM analysis. The specimens were prepared on 40 permanent human premolars without caries and restorations by Er:YAG laser (enamel 400mj/20Hz, dentin 200mj/20 Hz) and diamond bur in a high-speed hand piece for microleakage test and SEM analysis and they were randomly assigned to 8 groups: Group1: Bur + Clearfil SE Bond (Kuraray); Group2: Er:YAG laser (Syneron Dental Lasers) + Clearfil SE Bond; Group3: Bur + Single Bond Universal (3M ESPE); Group4: Er:YAG laser + Single Bond Universal; Group5: Bur + OptiBond All-in-One (Kerr); Group6: Er:YAG laser + OptiBond All-in-One; Group7: Bur + Acid Etch + Adper Single Bond 2 (3M ESPE); Group8: Er:YAG Laser + Acid Etch + Adper Single Bond 2. The specimens were subjected to a thermal cycling regimen of 1000 cycles between 5ºC and 55ºC; then they were immersed in a solution of 0,5% basic fuchsin dye for 24 hours. The teeth/restoration interfaces in longitudinally sectioned class V cavities were assessed for dye penetration under a light microscope by two investigators with a score table prepared in advance. The dentin/adhesive interfaces were evaluated for the structure of hybrid layer by SEM analysis. Data of microleakage test were statistically analyzed by Mann Whitney U Test, Kruskal Wallis Test and Dun's Post Hoc Test. No significance (p>0,05) had been determined between microleakage levels in Er:YAG laser prepared cavities and bur prepared cavities. In this study, Adper Single Bond 2, a total-etch adhesive system that is used after acid etching, have shown the utmost microleakage levels on cervical surfaces of cavities. Self-etch adhesives were found to be more successful on adhesion and microleakage. The difference between microleakage levels on cervical surfaces of all groups was statistically significant (p<0,001). OptiBond All-in-One self-etch adhesive has shown the least microleakage levels on cervical surfaces. In conclusion, data has demonstrated that Er:YAG laser cavity preparation could be a promising alternative to conventional bur preparation; however, further investigations are required for optimal bonding protocols on laser treated surfaces.en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectDiş Hekimliğitr_TR
dc.subjectDentistryen_US
dc.titleEr:Yag lazer ve geleneksel yöntem ile hazırlanmış sınıf v kavitelerde uygulanan farklı adeziv sistemlerin mikrosızıntı açısından incelenmesi
dc.title.alternativeMicroleakage study of different adhesive systems in class v cavities prepared BY ER:Yag laser and conventional technique
dc.typedoctoralThesis
dc.date.updated2019-03-07
dc.contributor.departmentRestoratif Diş Tedavisi ve Endodonti Anabilim Dalı
dc.subject.ytmLasers
dc.subject.ytmDental restoration
dc.subject.ytmDental leakage
dc.subject.ytmDental bonding
dc.subject.ytmMicroscopy-electron
dc.identifier.yokid10104429
dc.publisher.instituteDiş Hekimliği Fakültesi
dc.publisher.universityKOCAELİ ÜNİVERSİTESİ
dc.type.subdentistThesis
dc.identifier.thesisid417441
dc.description.pages153
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess