Show simple item record

dc.contributor.advisorBayındır, Yusuf Ziya
dc.contributor.authorKaralar, Buket
dc.date.accessioned2020-12-03T11:37:05Z
dc.date.available2020-12-03T11:37:05Z
dc.date.submitted2020
dc.date.issued2020-06-10
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/40963
dc.description.abstractAmaç: Bu çalışmanın amacı, 3 farklı universal adezivin dentine bağlanma dayanımına aktif uygulama süresinin ve hava basıncının etkisinin incelenmesidir.Materyal ve Metot: Çalışmada 3 adet universal adeziv sistem kullanıldı:Scotchbond Universal (3M ESPE, St.Paul, MN, ABD), Clearfil Universal Bond Quick (Kuraray Noritake Dental Inc., Okayama, Japonya), One coat 7 Universal (Coltène Whaledent, Altstätten, İsviçre). 150 adet insan molar dişinin minesi uzaklaştırılarak düz dentin yüzeyleri elde edildi. Rastgele olacak şekilde kullanılan adezivlere ve hava basınçlarına (20 Psi, 40 Psi ve 60 Psi) göre gruplara ayrılan örnekler daha sonra farklıuygulama sürelerine göre (5 sn, 10 sn, 20 sn) alt gruplara ayrıldı (n=5). Her adeziv sistem için hava basıncı uygulanmayan bir grup da kontrol grubu olarak atandı (n=5). Kontrol gruplarında üretici firma talimatlarının önerdiği aktif uygulama süresi boyunca bağlayıcıajan uygulandı. Adeziv uygulanmış dişlerin üzerine kompozit yerleştirildi (Voco Grandio Universal Nanohibrit kompozit, Cuxhaven, Almanya). Makaslama bağlanma kuvveti, universal bir test cihazı (Instron 3344, Instron Corp, Wilmington, ABD) kullanılarak ölçüldü. Kaydedilen veriler varyans analizi (ANOVA) ve Tukey HSD testleri ile analiz edildi (p<0,05).Bulgular: Basınç değişkeni (p<0,05) hariç diğer tüm değişkenler ve interaksiyonlarında istatistiksel olarak anlamlı farklılık tespit edilemedi (p>0,05). 20 Psi basınç uygulandığında elde edilen bağlanma değerleri, 60 Psi basınçtan anlamlı derecede yüksek bulundu (p<0,05). 20 ile 40 psi basınçları arasında ve 40 ile 60 Psi basınçları arasında istatistiksel olarak anlamlı farklılık tespit edilemedi (p>0,05).Sonuç: Hava basınçlarının universal adeziv sistemlerin bağlanma dayanımı üzerinde önemli bir etkisi vardır. Hafif şiddette (gentle) hava basıncı uygulaması dentinle iyi bir bağlantı oluşturabilir.Anahtar Kelimeler: Hava Basıncı, Makaslama Bağlanma Dayanımı, Universal adeziv, Uygulama Süresi.
dc.description.abstractAim: The aim of this study was to investigate the effect of the active application time and air pressure on the bond strength of 3 different universal adhesives.Materials and Methods: Three universal adhesive systems were used in the study: Scotchbond Universal (3M ESPE, St. Paul, MN, USA), Clearfil Universal Bond Quick (Kuraray Noritake Dental Inc., Okayama, Japan), One coat 7 Universal (Coltène Whaledent, Altstätten, Switzerland). Flat dentin surfaces were obtained from 150 human molar teeth. The samples are randomly divided into groups according to the adhesivesand the air pressures (20 Psi, 40 Psi and 60 Psi) and then subdivided into groups according to different application times (5 sec, 10 sec, 20 sec) (n=5). For each adhesive system, a group without air pressure was assigned as the control group (n=5). In the control groups, the bonding agent was applied during the active application time recommended by the manufacturer's instructions. A composite resin was placed on the adhesive-treated dentin surfaces (Voco Grandio Universal Nanohybrid composite, Cuxhaven, Germany). Shear bond strength was measured using a universal testing machine (Instron 3344, Instron Corp., Wilmington, USA). Data were analyzed by ANOVA and Tukey HSD tests (p<0,05).Results: There was no statistically significant difference in all variables and interactions except pressure variable (p<0.05). The bonding values of 20 Psi were significantly higher than 60 Psi (p<0.05). No statistically significant difference was found between 20 and 40 Psi and between 40 and 60 Psi (p>0.05).Conclusion: Air pressures have a significant effect on the bond strength of universal adhesive systems. Applying gentle air pressure could create a good bond strength with dentine.Keywords: Air Pressure, Application Time, Shear Bond Strength, Universal Adhesive.en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectDiş Hekimliğitr_TR
dc.subjectDentistryen_US
dc.titleSelf-etch mod universal adezivlerin dentine bağlanma dayanımına adezivin uygulama süresi ve hava basıncının etkisi
dc.title.alternativeEffect of adhesive application time and air pressure on dentine bond strengthof self-etch mode universal adhesives
dc.typedoctoralThesis
dc.date.updated2020-06-10
dc.contributor.departmentRestoratif Diş Tedavisi Anabilim Dalı
dc.identifier.yokid10334710
dc.publisher.instituteDiş Hekimliği Fakültesi
dc.publisher.universityATATÜRK ÜNİVERSİTESİ
dc.type.subdentistThesis
dc.identifier.thesisid620624
dc.description.pages102
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess