Show simple item record

dc.contributor.advisorÇetinarslan, Berrin
dc.contributor.authorIşik, Ulaş
dc.date.accessioned2020-12-29T12:12:29Z
dc.date.available2020-12-29T12:12:29Z
dc.date.submitted2011
dc.date.issued2018-08-06
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/409413
dc.description.abstractAmaç: Diabetes Mellitus (DM), hiperglisemi ile karakterize kronik sistemik bir hastalıktır. DM tanısındaki temel testlerden biri OGTT olmakla birlikte maliyet etkin değildir ve uygulamada zorluklar mevcuttur. Bu çalışmada HbA1c ve OGTT'nin 1.saatinin yeni diyabet olgularını tespit edebilmedeki değeri ve HbA1c düzeylerinin MS(Metabolik Sendrom) varlığı ile korelasyonunun belirlenmesi amaçlanmıştır.Gereç ve Yöntem: Çalışmaya Kocaeli Üniversitesi Genel Dahiliye ve Diyabet Polikliniğine başvuran ve OGTT endikasyonu konulan 200 (141 erkek, 59 kadın) hasta alındı. APG'na göre normoglisemik olan 177 hastaya OGTT uygulandı. Hastalar ADA OGTT kriterlerine göre normoglisemik, BGT ve DM olarak gruplandırıldı. Tüm hastaların HbA1c düzeyi ölçüldü ve ADA kriterlerine göre < %6.5 değeri normal kabul edildi. MS varlığı IDF 2005 kriterlerine göre belirlendi. OGTT 1. saat plazma glukoz düzeyinin 200 mg/dl ve üzerinde olmasının tanıdaki yeri değerlendirildi.Bulgular: Hastalar OGTT sonucuna göre normoglisemik (n=104), BGT (n=50) ve DM (n=46) olarak gruplandırıldı. ADA'nın kabul ettiği HbA1c eşik değeri ?%6.5 değerinin bu çalışmada yeni diyabet olgularını tespit edebilme sensitivitesi %47 ve spesifisitesi %95 olarak saptandı. Bu çalışmada yeni diyabet olgularını saptamada en yüksek sensitivite (%84) ve spesifisite (%68)'ye sahip eşik değer %5.8 olarak bulundu. MS olan 145 (%72.5) hastanın ortalama HbA1c düzeyleri anlamlı olarak artmıştı (p=0.001). Diyabet tanısında OGTT 1. saat değerinin ?200 olmasının yeni DM olgularını saptamada sensitivitesi %69 ve spesifisitesi %73 olarak bulundu. OGTT ile 1.saat plazma glukozu 200mg/dl ve üzerinde olup 2. saat plazma glukozu 200mg/dl'nin altında olan 40 hastanın 14'ünün (%35) HbA1c değeri %5.8 ve üzerinde idi.Sonuçlar: ADA önerdiği diyabet tanısında HbA1c ?%6.5 eşik değer ile kullanılmasının özellikle sensivitesi bu çalışmada düşük bulunmuştur. Çalışmamızda HbA1C'nin diyabet tanısında kullanılabileceği en yüksek sensitivite ve spesifiteye sahip olduğu eşik değer %5.8 olarak saptanmıştır.Anahtar Kelimeler: HbA1c, D. Mellitus,
dc.description.abstractAim: Diabetes Mellitus (DM) is a chronic systemic disease characterised with hyperglicemia. One of the main tests of the diagnosing of DM is OGTT. Since OGTT is not cost-effective and difficult, cheaper and easier tests are needed. We aimed in this study to research the ability of the HbA1C and 1.hour plasma glucose levels in OGTT in the diagnosis of DM and to define the correlation with the metabolic syndrome (MS).Materials and Methods: The study group consisted of 200 patients (141 female, 59 male with mean age 46.3) who had OGTT indication from the Internal Medicine and Diabetes Mellitus Outpatient Clinics of Kocaeli University. 177 normoglicemic pateins according to fasting plasma glucose were performed OGTT. The results were classified in three groups involved normoglycemia, IGT and DM according to the criteria of ADA. MS was defined with IDF 2005 criteria. All patiens were performed the HbA1C analyze with the normal level <6.5% that ADA provided. We used as determinant for the 1.h plasma glucose level 200? mg/dl.Results: 104 patients had normal glucose levels. 46 patients were classified as DM and 50 patients as IGT. In our study we found the sensitivity of the HbA1C levels for the diagnosis of DM 47% and the specifity was 95%. The most sensitivity and spesifity having cut-off value of HbA1C was 5.8%. 145 patients of study group (72.5%) had metabolic syndrome. The HbA1C levels are statistically significant increased in MS group (p=0.001; HbA1C:5.8 vs 5.2). The sensitivity and the specifity of the 1.hour plasma glucose levels in OGTT were 69%, 73%, respectively. Glucose levels of 40 patients (35%) were ?200mg/dl in 1. hour and <200 mg/dl in 2. hour 14 patients from this group(35%) had HbA1c values ?5.8%.Conclusion: In our study the ADA provided HbA1C levels (6.5%) for the diagnosing DM had low sensitivity. Our results show the highest sensitivity and specifity in the diagnosing of DM was with the cut-off value 5.8. The patients with the plasma glucose levels in OGTT 1.hour >200 and 2.hour<200 mg/dl should be monitored closely for the developing of DM.Key words: HbA1c, Diabetes Mellitus, OGTTen_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectEndokrinoloji ve Metabolizma Hastalıklarıtr_TR
dc.subjectEndocrinology and Metabolic Diseasesen_US
dc.titleHbA1C düzeyinin diyabetes mellitus tanısındaki yeri, mevcut tanı kriterleri ile karşılaştırılması
dc.title.alternativePlace HbA1C in the diagnosis of diabetes mellitus, comparison with current diagnostic criteria
dc.typedoctoralThesis
dc.date.updated2018-08-06
dc.contributor.departmentİç Hastalıkları Anabilim Dalı
dc.subject.ytmMetabolic diseases
dc.subject.ytmDiabetes mellitus
dc.subject.ytmDiagnosis
dc.subject.ytmDiagnosis-differential
dc.subject.ytmHemoglobin A-glycosylated
dc.identifier.yokid402395
dc.publisher.instituteTıp Fakültesi
dc.publisher.universityKOCAELİ ÜNİVERSİTESİ
dc.type.submedicineThesis
dc.identifier.thesisid293489
dc.description.pages45
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess