Show simple item record

dc.contributor.advisorÜnal, Nedim
dc.contributor.authorÖzden, Hilmi
dc.date.accessioned2020-12-29T11:26:06Z
dc.date.available2020-12-29T11:26:06Z
dc.date.submitted1995
dc.date.issued2018-08-06
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/401078
dc.description.abstractÖZET MRG tekniği ile Omurga'nın torakal bölümünde; medulla spinalis, dura materden itibaren canalis vertebralis, corpus vertebralislerin, sagittal (AP) ve transvers (RL) çap ölçümleri yapılmıştır. M. spinalis alanı ve spatium subarachnoideüm çapları ise ölçüm değerleri yardımı ile hesaplanmıştır. Ankara Sevgi Hastanesi'ne MRG için başvuran 50 olgu üzerinde yaptığımız çalışma prospectif olarak gerçekleştirilmiştir. Horizontal kesitlerde elde ettiğimiz çapları istatistiksel olarak değerlendirdik. Torakal bölümde; m. spinalis sagittal çapı Tı'den Tn'e doğru gittikçe artmakta (6.71 nını-7.24 mm), transvers çap ise Tı'den (8.92 mm) T5'e (8.93 mm) kadar sabit, T5'den (8.93 mm) T9'a (8.70 mm) kadar 0.2 mm'lik bir azalma olmaktadır. Tıo'dan (8.80 mm) Tn'e (9.10 mm) doğru artmaktadır. Vertebra seviyelerine karşılık gelen medulla spinalis alanları bu çaplar kullanılarak hesaplanmıştır. Canalis vertebralis'e ait bulgularımızda ise sagittal çap Tı'de (11.07 mm) genişleme, T2'de (10.94 mm) azalma göstermektedir. Sagittal çap T3'den (11.04 mm) T10'a (11.50 mm) kadar sabittir, Tıo'dan (11.50 mm) itibaren T^'ye (14.06 mm) doğru artmaktadır. Transvers çap ise Tı'de (13.85 mm) geniş T2'de (12.74 mm) azalmaktadır, T3'den (13.26 mm) Tg'a (13.52 mm) kadar sabittir. T10'dan (13.84 mm) itibaren büyümektedir. Canalis vertebralis'de m.spinalis'in Intumescentia Lumbalis bölgesine uyan seviyelerde genişleme izlenmiştir. Corpus vertebralis ölçümlerinde sagittal çap Tı'den (16.21 mm) Tn'e (27.16 mm), transvers çap Tı'den (25.57 mm) T^'ye (35.64 mm) doğru artmaktadır. Spatium subarachnoideum'un sagitU.pı T^den (4.22 mm) Ti2'ye (7.33 mm) doğru artmaktadır. Transvers çapı ise Tı'den (4.82 mm) T3'e (4.34 mm) küçülmüş T4'den (4.10 mm) TI2'ye (9.02 mm)11 doğru artmıştır. Elde edilen ölçümleri, daha önceki morfolojik ve radyolojik çalışmaların sonuçlarıyla karşılaştırdık. Araştırmacıların kadavra ölçümleri, direkt röntgen, myelografi, myelo-BT ve BT çalışmaları, MRG ile karşılaştırıldığında; MRG'nin kadavra ölçüm değerlerine yakın değerler vermesi, diğer tekniklere göre üstün olduğunu göstermiştir. İlaveten bir kadavra'dan, çalıştığımız bölgenin makroskobik ölçümleri, radyografi, myelo-BT ve MRG ile ölçümleri elde edilmiştir. Bu çalışma ilerdeki çalışmalara bir örnek teşkil etmesi için yapılmıştır. 50 olguluk çalışmamız ise radyolojik görüntüleme alanında çalışan hekimlerin başvurabileceği bir örneklem oluşturmaktadır. Anahtar Kelimeler : Manyetik Rezonans Görüntüleme, Columna vertebralis, Vertebrae thoracales, Medulla spinalis, Canalis vertebralis, Corpus vertebralis, Spatium subarachnoideum, Sagittal ve transvers çaplar.
dc.description.abstractHI SUMMARY The sagittal (AP) and the transverse (RL) diameters of the spinal cord, spinal canal (from dura mater) and vertebral body, at the thoracic part of the spine, were measured by MRI. The area of the spinal cord and diameters of subarachnoid space were calculated by the use of those measurements. This study is performed prospectively at the Ankara Sevgi Hospital in 50 patients undergoing MR imaging for various disorders. The results were interpreted statistical. At the thoracic part the sagittal diameter of the spinal cord increased gradually from Tj toTn (6.71 mm-7.24 mm), the transverse diameter was constant from T! (8.92 mm) to T5 (8.93 mm), decreased from T5 (8.93 mm) to T 9 (8.70 mm) by 0.2 mm and increased from T10 (8.80 mm) to Tn (9.10 mm). The areas of the spinal cord that correspond to the same levels of vertebral bodies were calculated by the use of diameters. Our results about spinal canal showed that the sagittal diameter widened at T i( 1 1.07 mm), but narrowed at T2 (10.94). The sagittal diameter was constant from T3 (11.04 mm) to Tjo( 11.50 mm), but increased from T10 (1 1.50 mm) to T12 (14.06 mm). However, transverse diameter widened at Tj (13.85 mm) and narrowed at T2 (12.74 mm) and constant from T 3 (13.26 mm) to T9 (13.52 mm). It gradually increased, from T10 (13.84 mm). There is a widening at the lumbal enlargement of spinal cord that corresponds to the levels of spinal canal. The measurements of the vertebral body showed that the sagittal diameters were increased from Tj (16.21 mm) to Tn (27.16 mm), and the transverse diameters were increased from-T(25.57 mm) to Tj2 (35.64 m m ). The sagittal diameters of the subarachnoid space increased from T4IV (4.22 mm) to T 1 2 (7.33 mm), however the transverse diameters were decreased from Tj (4.82 mm) to T3 (4.34 mm) and increased from T4 (4.10 mm) to TJ2 (9.02 mm). We compared, obtained measurement results with the results of previous morphologic and radiologic studies. When compared to the macroscobic measurements of the thoracic cord of eadeveric cases, radiographic, myelographic, myelo-CT and CT measurements. MRI was superior to the others for being closer to the macroscobic measurements of the cadaveric cases. In addition, macroscobic measurements of the studied part and the measurements by radiography, myelo-CT and MRI were obtained from 1 cadaveric case. This study was made to be a sample case for the following studies. This study of 50 case is a sample for the clinitions working at the field of radiologic imaging for refering. Key words Magnetic Resonance Imaging, Thoracic cord*, spinal canal, vertebral body, subarachnoid space, sagittal and transverse diameters. *îngili&ce makalelerde `thoracic cord` terimi ile omurga'nin torakal bölümüne karşılık gelen m. spinalis anlaşılmaktadır.en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectMorfolojitr_TR
dc.subjectMorphologyen_US
dc.titleOmurga`nın Torakal Bölümü`nde medulla spinalis çaplarının manyetik rezonans görüntüleme (MRG) tekniği ile ölçümü ve değerlendirilmesi
dc.typedoctoralThesis
dc.date.updated2018-08-06
dc.contributor.departmentAnatomi Anabilim Dalı
dc.subject.ytmSpinal cord
dc.subject.ytmMagnetic resonance imaging
dc.subject.ytmSpine
dc.identifier.yokid48047
dc.publisher.instituteSağlık Bilimleri Enstitüsü
dc.publisher.universityESKİŞEHİR OSMANGAZİ ÜNİVERSİTESİ
dc.identifier.thesisid48047
dc.description.pages107
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess