dc.description.abstractÇalışmamızın amacı; Yoğun bakım ünitesinde takip ve tedavisi yapılan hastalarında sıvı tedavisinde ters Trendelenburg pozisyonunun santral venöz basınç ?y? dalgası değerine olan etkisinin araştırılmasıdır.Fakülte Etik Kurulunun onayı alındıktan sonra hastalar, yakınlarından aydınlatılmış onamları alınarak çalışmaya dahil edildiler. Hastalar; Grup I: sıvı açığı olan, Grup II: sıvı açığı olmayan olarak gruplandırıldı.Hemodinamik monitörizasyon sağ internal juguler vene PAC yerleştirilmesi ile sağlandı, tüm hastaların EKG ve santral venöz basınç dalgası mönitörizasyonu yapıldı.KH, Art S, Art D, OAB, CVP, PAM, PCWP, CO, CI, SV, SVI, SVR, SVRI, PVR, PVRI, LVSW, LVSWI, RVSW, RVSWI, LHCPP, ?y? dalgası değerlerinin ölçümü ilk olarak supin pozisyonda, ikinci olarak 30 derece ters Trendelenburg pozisyonuna alındıktan 1 dakika sonra, üçüncü ölçümler supin pozisyonda hastalara 10 dakikada 500 ml %0,9 NaCl verildikten sonra ve son olarak hastalar tekrar 30 derece ters Trendelenburg pozisyonuna alındıktan sonra yapıldı. Bu parametreler gruplar arasında ve grup içinde karşılaştırıldıHastaların demografik verileri ile KH, Art S, Art D, OAB, CO, CI, SV, SVI, SVR, SVRI, PVR, PVRI, LVSW, LVSWI, RVSW, RVSWI ve LHCPP değerlerinde gruplar arasında ve grup içi değerlendirilmede istatistiksel olarak anlamlı farklılık bulunmadı. Gruplar arası ve grup içi değerlendirmede Grup I'de yapılan ölçümlerde PAM, PCWP CVP ve y dalgası ölçümünde, Grup II'de ise CVP ve y dalgası ölçümünde istatistiksel olarak anlamlı farklılık olduğu görüldü (p<0,05Sonuç olarak; YBÜ'de takip edilen hastalarda, santral venöz kateteriyle ölçümü yapılan ?y? inişinin değerlendirilmesi sonucunda sıvı tedavisinin yönlendirilebileceği anlaşıldı.
dc.description.abstractThe aim of this study is to find out the effect of reverse Trendelenburg position on central venous pressure of ?y? wave value during the fluid therapy on the patients having been treated in ICU.After the approval ethic committee of the faculty and their primary relatives? approval and permission, the patients were included to this study. These patients were classed in two groups; Group I (the patients lacking fluid) and Group II (the patients not lacking fluid).Hemodynamic monitorization was conducted by placing of right internal vein PAC. All patients? ECG and central venous pressure wave monitorizations were carried out.The measurements for HR, Art S, Art D, MAP, CVP, PAM, PCWP, CO, CI, SV, SVI, SVR, SVRI, PVR, PVRI, LVSW, LVSWI, RVSW, RVSWI, LHCPP ?y? wave values were taken first in supine position, second 1 minute after 30 degrees reverse Trendelenburg position, third after 500 ml. of 0,9% NaCl was given to the patients in 10 minutes, and last after the patients were returned to 30 degrees reverse Trendelenburg position.No statistically meaningful difference was found between groups and within groups assessments for the demographic data and KH, Art S, Art D, OAB, CO, CI, SV, SVI, SVR, SVRI, PVR, PVRI, LVSW, LVSWI, RVSW, RVSWI, LHCPP measures of the patients. During between groups and within groups assessments, statistically meaningful differences were recorded in Group I?s PAM, PCWP CVP, and y wave measurements, and in Group II?s CVP, and y wave measurements.In conclusion, determination of fluid therapy was found by the evaluation of ?y? value measured with central venous catheter on the patient having been treated in ICU.en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectAnestezi ve Reanimasyontr_TR
dc.subjectAnesthesiology and Reanimationen_US
dc.titleSıvı tedavisinde hastaya verilen pozisyonun santral venöz basınç ?y? dalgası değerine olan etkisinin araştırılması
dc.title.alternativeInvestigation of effects of patients? position on central venous pressure?s ?y? wave value during the fluid therapy
dc.typedoctoralThesis
dc.date.updated2018-08-06
dc.contributor.departmentAnesteziyoloji ve Reanimasyon Anabilim Dalı
dc.identifier.yokid337719
dc.publisher.instituteTıp Fakültesi
dc.publisher.universityFIRAT ÜNİVERSİTESİ
dc.type.submedicineThesis
dc.identifier.thesisid242101
dc.description.pages84
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess