Examination of corrosion effects on orthodontic brackets under simulated gastroesophageal reflux disease (GERD) – an ın-vitro study
dc.contributor.advisor | Nalbantgil, Didem | |
dc.contributor.author | Akin Özgünler, Elif | |
dc.date.accessioned | 2020-12-29T06:57:20Z | |
dc.date.available | 2020-12-29T06:57:20Z | |
dc.date.submitted | 2019 | |
dc.date.issued | 2020-04-01 | |
dc.identifier.uri | https://acikbilim.yok.gov.tr/handle/20.500.12812/339982 | |
dc.description.abstract | Bu çalışmanın amacı taklit edilmiş Gastroözofageal Reflü Hastalığı ortamında paslanmaz çelik braketlerin (N=180, üst santral kesici diş) korozyonu sonrası yüzey pürüzlülüğü ve iyon salınımını incelemektir. Farklı pH'lar ve sürelerin etkileri değerlendirilmiştir. Braketler rastgele 3 ana gruba ve 15 alt gruba ayrılmıştır (n = 12). Ana grupları oluşturan pH çözeltileri: gastrik regürjitasyonun şiddetli (pH 1,5) ve orta (pH 3,0) derecesini simüle edenler ve kontrol grubu olarak yapay tükürüktür (pH 7,0). Her pH grubu, braketlerin çözeltilerde geçen sürelerine (30 dakika, 12 saat, 24 saat, 1 hafta ve 1 ay) göre alt gruplara bölünmüştür. Örneklerin tümü belirtilen zamanlarda inkübatörde tutulmuştur. Braket slotlarının ortalama yüzey pürüzlülüğü optik profilometre ile incelenmiştir. Braketlerden çözeltilere salınan metal iyonlarını (Fe, Ni, Cr) belirlemek için indüktif olarak eşleşmiş plazma kütle spektrometresi (ICP-MS) kullanılmıştır. Deneyler öncesi her braket slotunun başlangıç yüzey pürüzlülüğü (ISR) ölçülmüştür. Deneylerden sonra, her braket slotunun final yüzey pürüzlülüğü (FSR) ve FSR-ISR farkı incelenmiştir ve sonuçlar, tüm ana pH gruplarında ve zaman alt gruplarında istatistiksel olarak karşılaştırılmıştır. Ayrıca, 30 dakika, 24 saat ve 1 aydaki iyon salımı incelenmiş ve sonuçlar tüm ana pH gruplarında ve belirtilen zaman alt gruplarında istatistiksel olarak karşılaştırılmıştır. pH grupları farklı zaman aralıklarında FSR açısından değerlendirildiğinde, tüm pH gruplarındaki istatistiksel olarak anlamlı fark ilk olarak 24 saat sonra ortaya çıkmıştır (p = 0,0001). FSR-ISR, tüm ana pH gruplarında ve zaman alt gruplarında istatistiksel olarak anlamlı bulunmuştur (p = 0,0001). Ortamın asiditesi arttıkça ve çözeltilerde geçen süre uzadıkça, braketlerin korozyonunun arttığı gözlenmiştir. En yüksek FSR, FSR-ISR ve iyon salımı, 1 ayda pH 1,5 grubunda bulunmuştur. pH 7,0 grubunun tüm zaman alt gruplarındaki iyon salımının (Ni için 30 dakika hariç) gastrik çözeltilerdeki iyon salınımından daha düşük olduğu bulunmuştur. Braketlerden iyon salınımı tüm zaman aralıklarında ve tüm pH gruplarında meydana gelmiştir, ancak iyon salınım miktarları toksik sınırların altında bulunmuştur. | |
dc.description.abstract | The aim of this study was to investigate the surface roughness and ion release of stainless steel brackets (N=180, upper central incisor) after corrosion under simulated Gastroesophageal Reflux Disease. The effects of different pHs and durations were evaluated. Brackets were randomly divided into 3 main groups and 15 subgroups (n=12). The pH solutions forming the main groups were: simulating severe (pH 1.5) and moderate (pH 3.0) forms of gastric regurgitation and artificial saliva (pH 7.0) as the control group. Each pH group was divided into subgroups according to the brackets' elapsed times in the solutions (30 minutes, 12 hours, 24 hours, a week, a month). All of the specimens were kept in an incubator, at specified times. The average surface roughness of bracket slots was examined with optical profilometer. Inductively coupled plasma mass spectrometry (ICP-MS) was used to determine the metal ions (Fe, Ni, Cr) released to the solutions from brackets. Before immersions, initial surface roughness (ISR) of each braket slot was measured. After immersions, final surface roughness (FSR) and the difference of FSR-ISR of each bracket slot were examined, and the results were compared statistically in all main pH groups and time subgroups. Also, ion release at 30 minutes, 24 hours and 1 month were examined and the results were compared statistically in all main pH groups and specified time subgroups. When the pH groups were evaluated in terms of FSR at different time intervals, the statistically significant difference in all pH groups firstly occured after 24 hours (p=0.0001). The FSR-ISR was statistically significant in all main pH groups and time subgroups (p=0.0001). As the acidity of the environment and the immersion time increased, increased corrosion of brackets was observed. The highest FSR, FSR-ISR and ion release were found in pH 1.5 group at 1 month. pH 7.0 group's ion release at all time subgroups (except 30 minutes for Ni) was found to be lower than gastric solutions. Ion release from the brackets occurred in all pH groups at all time intervals, but the amounts of ion release were below the toxic limits. | en_US |
dc.language | English | |
dc.language.iso | en | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Attribution 4.0 United States | tr_TR |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject | Diş Hekimliği | tr_TR |
dc.subject | Dentistry | en_US |
dc.title | Examination of corrosion effects on orthodontic brackets under simulated gastroesophageal reflux disease (GERD) – an ın-vitro study | |
dc.title.alternative | Gastroözofageal reflü hastalığı (GÖRH) taklit edilmiş ortamda ortodontik braketlerdeki korozyon etkilerinin incelenmesi – in-vitro çalışma | |
dc.type | doctoralThesis | |
dc.date.updated | 2020-04-01 | |
dc.contributor.department | Ortodonti Anabilim Dalı | |
dc.identifier.yokid | 10318322 | |
dc.publisher.institute | Sağlık Bilimleri Enstitüsü | |
dc.publisher.university | YEDİTEPE ÜNİVERSİTESİ | |
dc.identifier.thesisid | 618077 | |
dc.description.pages | 98 | |
dc.publisher.discipline | Diğer |