Characterisation of ultrasonic transducers used in medical applications and investigation of their effects in phantom tissue
dc.contributor.advisor | İnce, Ahmet Turan | |
dc.contributor.advisor | Karaböce, Baki | |
dc.contributor.author | Karaböce, Baki | |
dc.date.accessioned | 2020-12-29T06:46:10Z | |
dc.date.available | 2020-12-29T06:46:10Z | |
dc.date.submitted | 2014 | |
dc.date.issued | 2018-08-06 | |
dc.identifier.uri | https://acikbilim.yok.gov.tr/handle/20.500.12812/338815 | |
dc.description.abstract | Bu tezin genel amacı yüksek yoğunluklu tıbbi uygulamalarda kullanılan odaklanmış ultrason (HIFU) dönüştürücüleri karakterize etmek ve fantom dokudaki etkisini araştırmaktır. HIFU dönüştürücülerin iki türü, elektrik akustik ve termal yöntemlerle karakterize edilmiştir. HIFU dönüştürücülerin anlık giriş elektrik gücünün ölçülmesi için yeni bir yöntem kullanılmıştır. Amaç uygulanan elektrik enerjisine karşı üretilen ultrasonik güçler arasında bir ilişki kurmak ve HIFU dönüştürücülerin etkinliğini ölçmektir. Ultrasonik basınç ölçüm sistemi, TÜBİTAK UME Ultrasonik Laboratuvarı'nda tasarlanmış ve üretilmiştir. Sistem, su deposu, konumlandırma sistemi, ölçüm cihazları ve kontrol/yazılım bölümlerinden oluşur. Basınç alanının ölçülmesi ve 2-eksen ve 3-eksen haritalama incelenerek HIFU tarafından yayılan alan araştırılmıştır. Fantom dokuda sıcaklık ölçüm düzeneği kurulmuştur. TÜBİTAK UME Sıcaklık Laboratuarı'nda üretilen iki sıcaklık sensörü kullanılmıştır. Pt100 (Platin dirençli termometre) sıcaklık sensörleri ve ısılçiftler fantom doku içine yerleştirilmiştir. Sıcaklık değişimi ve sıcaklık dağılımı araştırılmıştır. Ultrasonik güç, elektrik gücü, ultrasonik basınç ve sıcaklık artışı arasındaki ilişkiler sunulmuştur. Literatürde mevcut teorik model ile deneysel sonuçlar karşılaştırılmış ve uyum gözlenmiştir. Ultrason basınç alanı için teorik model, KZK (Khokhlov, Zabolotskaya and Kuznetsov) doğrusal olmayan parabolik denklemi ve fantom dokudaki sıcaklık artışına sebep olan genellikle Pennes' bioheat transfer denklemi ile açıklanan HIFU enerji emilimi kullanılarak gerçekleştirilmiştir. | |
dc.description.abstract | The overall goal of this thesis is to characterize the high intensity focused ultrasound (HIFU) transducers used in medical applications and to investigate the effect in phantom tissue. Two types of HIFU transducers have been characterized by electrical, acoustical and thermal methods. A new method has been presented for measurement of instantaneous input electrical power of HIFU transducers. The aim is to establish a relationship between ultrasonic powers produced due to applied electrical power and measure the effectiveness of HIFU transducers. New ultrasound pressure measurement system has been designed and constructed at TUBİTAK UME Ultrasound Laboratory. System consists of a water tank, positioning system, measurement devices and a controlling program. The ultrasound field radiated by HIFU has been investigated by measuring its pressure field and mapping in 2-D and 3-D. A temperature measurement set up in a phantom tissue has been constructed. Two temperature sensors that were produced at TÜBİTAK UME Temperature laboratories were used. Platinum resistance (Pt100) temperature sensors and thin wire thermocouples are embedded into a phantom tissue. Temperature change and temperature distribution have been investigated. Correlations between ultrasonic power, electrical power, ultrasonic pressure and temperature rise have been presented. Theoretical model found in literature and experimental results were compared and an agreement was shown. Theoretical model for ultrasound pressure field was realized by using a KZK (Khokhlov, Zabolotskaya and Kuznetsov) nonlinear parabolic equation and temperature rise in phantom tissue caused by absorption of HIFU energy is often described using Pennes' bioheat transfer equation. | en_US |
dc.language | English | |
dc.language.iso | en | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Attribution 4.0 United States | tr_TR |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject | Fizik ve Fizik Mühendisliği | tr_TR |
dc.subject | Physics and Physics Engineering | en_US |
dc.subject | Fiziksel Tıp ve Rehabilitasyon | tr_TR |
dc.subject | Physical Medicine and Rehabilitation | en_US |
dc.title | Characterisation of ultrasonic transducers used in medical applications and investigation of their effects in phantom tissue | |
dc.title.alternative | Medikal uygulamalarda kullanılan ultrasonik dönüştürücülerin karakterizasyonu ve etkilerinin fantom dokuda araştırılması | |
dc.type | doctoralThesis | |
dc.date.updated | 2018-08-06 | |
dc.contributor.department | Fizik Anabilim Dalı | |
dc.subject.ytm | Ultrasonic therapy | |
dc.subject.ytm | Physical medicine | |
dc.subject.ytm | Ultrasound | |
dc.identifier.yokid | 10044135 | |
dc.publisher.institute | Fen Bilimleri Enstitüsü | |
dc.publisher.university | YEDİTEPE ÜNİVERSİTESİ | |
dc.identifier.thesisid | 416197 | |
dc.description.pages | 146 | |
dc.publisher.discipline | Diğer |