Farklı oranlardaki biyoaktif cam ile modifiye edilen rezin esaslı fissür örtücülerin antibakteriyel ve fiziksel özelliklerinin karşılaştırmalı olarak değerlendirilmesi
dc.contributor.advisor | Aykut Yetkiner, Arzu | |
dc.contributor.author | Garip, Gökçe | |
dc.date.accessioned | 2020-12-29T06:19:06Z | |
dc.date.available | 2020-12-29T06:19:06Z | |
dc.date.submitted | 2017 | |
dc.date.issued | 2018-08-06 | |
dc.identifier.uri | https://acikbilim.yok.gov.tr/handle/20.500.12812/334202 | |
dc.description.abstract | ÖZETFarklı Oranlardaki Biyoaktif Cam ile Modifiye Edilen Rezin Esaslı Fissür Örtücülerin Antibakteriyel ve Fiziksel Özelliklerinin Karşılaştırmalı Olarak DeğerlendirilmesiGünümüzde restoratif materyallerin gelişimine paralel olarak koruyucu diş hekimliğinde önemli yer tutan pit ve fissür örtücülerin birçok farklı tipi üretilmektedir. Diş hekimliğindeki bu gelişmelerden bir tanesi de remineralize edici ve antibakteriyel özelliğe sahip olduğu bildirilen biyoaktif camın (BAC) restoratif materyallere eklenerek kullanılmasıdır. Bu çalışmanın amacı farklı oranlarda BAC eklenen rezin esaslı fissür örtücülerin fiziksel özelliklerinin ve antibakteriyel etkinliklerinin araştırılmasıdır.Çalışmada yüksek, orta ve düşük doldurucu içerikli rezin esaslı fissür örtücülerin her birine ağırlıkça %5, %10 ve %15 oranlarında BAC eklendi. BAC eklenmeyen fissür örtücüler kontrol grubu olarak kullanıldı. Elde edilen yeni materyallerin makaslama bağlanma dayanımı, mikrosertlik, mikrosızıntı ve antibakteriyel etkinlikleri değerlendirildi. Fissür örtücülerin mineye olan makaslama bağlanma dayanımı üniversal test cihazı ile değerlendirildi. Disk şeklinde hazırlanan fissür örtücülerin mikrosertlikleri Vicker's testi ile belirlendi. Mikrosızıntı değerlendirmesinde boya penetrasyon yöntemi kullanıldı. Fissür örtücülerin S. mutans üzerine antibakteriyel etkisi agar difüzyon test yöntemi ile değerlendirildi.Çalışmada uygulanan testler sonucunda fissür örtücüye %5 oranında BAC eklenmesinin fissür örtücününün makaslama bağlanma dayanımını değiştirmediği görülmüştür (p>0,05). %5 oranında BAC eklenen fissür örtücüler kontrol grubundan yüksek mikrosertlik değeri gösterirken, %10 ve %15 oranlarda BAC eklenenlerin mikrosertlikleri kontrol grubundan düşük bulunmuştur (p<0,05). Fissür örtücünün doldurucu oranının artmasıyla makaslama bağlanma dayanımı ve mikrosertliğinin arttığı görülmüştür. Ayrıca fissür örtücüye %5 oranında BAC eklenmesinin genel olarak fissür örtücünün mikrosızıntısını olumsuz yönde etkilemediği görülmüştür. Agar disk difüzyon testi ile değerlendirilen farklı oranlarda BAC içeren tüm örneklerde S. mutans'a karşı antibakteriyel etkinlik tespit edilmemiştir.Sonuç olarak rezin esaslı fissür örtücülere %5 oranında BAC eklenmesi fissür örtücülerin mekanik özelliklerini olumsuz yönde etkilemediği için tavsiye edilebilir.Anahtar sözcükler: antibakteriyel etkinlik, biyoaktif cam, makaslama bağlanma dayanımı, mikrosertlik, mikrosızıntı, rezin esaslı fissür örtücü | |
dc.description.abstract | ABSTRACTComparative Evaluation of Antibacterial and Physical Characteristics of Resin-Based Fissure Sealants Modified With Bioactive Glass In Different ProportionsNowadays many different types of pit and fissure sealants are marketed in preventive dentistry with the development of restorative materials. One of these developments in dentistry is the use of bioactive glass (BAG) which is reported to have remineralization and antibacterial activity added into restorative materials. The aim of this study was to evaluate the antibacterial and physical characteristics of resin-based fissure sealants modified with bioactive glass in different proportions.In this study 5%, 10% and 15% BAG by weight was added to each high, medium and low filler containing resin based fissure sealants. BAG free sealants were used as control group. Shear bond strength, microhardness, microleakage and antibacterial activity of created new materials were evaluated. Shear bond strength to the enamel of fissure sealants was evaluated with universal test machine. Microhardness of the disc-shaped prepared fissure sealants was determined by Vicker's test. Dye penetration method was used in microleakage evaluation. Antibacterial effect of fissure sealants on S. mutans was evaluated by agar diffusion test method.As a result of the tests used in this study it was shown that adding BAG in sealants in 5% proportions did not change shear bond strength (p>0.05). While added 5% BAG added fissure sealants showed higher hardness values than control group, fissure sealants with high proportions of BAG such as 10% and 15% showed lower hardness values than control group (p<0.05). It has been observed that shear bond strength and microhardness increases by increasing the amount of filler of fissure sealants. It has also been observed that adding 5% BAG to fissure sealant mostly did not affect microleakage of sealants negatively. In all samples containing different ratios of BAG, any antibacterial activity could not be determined against S. mutans in agar diffusion test.Adding BAG with the ratio of 5% to fissure sealants can be recommended for its non-negative effects on the mechanical properties of fissure sealants.Keywords: antibacterial activity, bioactive glass, microhardness, microleakage, resin based fissure sealant, shear bond strength | en_US |
dc.language | Turkish | |
dc.language.iso | tr | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Attribution 4.0 United States | tr_TR |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject | Diş Hekimliği | tr_TR |
dc.subject | Dentistry | en_US |
dc.title | Farklı oranlardaki biyoaktif cam ile modifiye edilen rezin esaslı fissür örtücülerin antibakteriyel ve fiziksel özelliklerinin karşılaştırmalı olarak değerlendirilmesi | |
dc.title.alternative | Comparative Evaluation of Antibacterial and Physical Characteristics of ResinBased Fissure Sealants Modified With Bioactive Glass In Different Proportions | |
dc.type | doctoralThesis | |
dc.date.updated | 2018-08-06 | |
dc.contributor.department | Pedodonti Anabilim Dalı | |
dc.subject.ytm | Dental fissures | |
dc.subject.ytm | Anti-bacterial agents | |
dc.subject.ytm | Dental stress analysis | |
dc.subject.ytm | Dental leakage | |
dc.subject.ytm | Dental materials | |
dc.subject.ytm | Bioactive glass | |
dc.subject.ytm | Pit and fissure sealants | |
dc.identifier.yokid | 10146866 | |
dc.publisher.institute | Diş Hekimliği Fakültesi | |
dc.publisher.university | EGE ÜNİVERSİTESİ | |
dc.type.sub | dentistThesis | |
dc.identifier.thesisid | 462379 | |
dc.description.pages | 114 | |
dc.publisher.discipline | Diğer |