Show simple item record

dc.contributor.advisorAk, Dilek
dc.contributor.authorDal, Arin Gül
dc.date.accessioned2020-12-28T13:44:16Z
dc.date.available2020-12-28T13:44:16Z
dc.date.submitted2002
dc.date.issued2018-08-06
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/328831
dc.description.abstractÖZET Yüksek Lisans Tezi MİTOMİSİN C NİN SÜREKLİ AKIŞ ENJEKSİYON ANALİZİ İLE MİKTAR TAYİNİ, VALİDASYONU VE FLAKONLARINA UYGULANMASI ARIN GÜL DAL Anadolu Üniversitesi Sağlık Bilimleri Enstitüsü Analitik Kimya Anabilim Dalı Danışman:Doç. Dr. Dilek Doğrukol-Ak 2002 Bu çalışmada mitomisin C nin farmasötik flakonlarında miktar tayini için sürekli akış enjeksiyon analizi yöntemi tarif edilmektedir. Taşıyıcı çözelti olarak Britton-Robinson tampon sistemi kullanılmıştır ve akış hızı 1.0 mL/dk' dır. Mitomisin C sinyalleri UV-spektrofotometrik detektör kullanılarak 363 nm' de kaydedilmiştir. Miktar tayini için pik alanı ve pik yüksekliği sinyalleri kullanılmıştır. Yöntemin kesinliği ve doğrusallığı bu sinyallerle gösterilmiştir. Sinyal/gürültü oranı 3 kriterine göre yöntemin saptama sının olarak 1.93x1 0`8 M ve tayin sınırı olarak 6.45X10`8 M değerleri hesaplanmıştır. Yöntemin uygulanması ile elde edilen sonuçlar standart yöntemler olan UV-spektrofotometrik ve yüksek performanslı sıvı kromatografik yöntemlerin sonuçları ile karşılaştırılmıştır. Pik alanı sinyalleri ile standart yöntemler arasındaki farkın istatistiksel olarak önemli olmadığı bulunmuştur. Bu çalışmada geliştirilen sürekli akış enjeksiyon analizinin kesin, doğru, duyarlı ve ucuz bir yöntem olduğu söylenebilir. Anahtar Kelimeler: Mitomisin C, Sürekli Akış Enjeksiyon Analizi, Validasyon, Flakon
dc.description.abstractABSTRACT Master of Science Thesis A VALIDATED METHOD FOR THE DETERMINATION OF MITOMYCIN C BY FLOW-INJECTION ANALYSIS AND ITS APPLICATION TO FLACONS ARIN GÜL DAL Anadolu University Institute of Health Sciences Department of Analytical Chemistry Supervisor: Assoc. Prof. Dilek Doğrukol-Ak 2002 A flow injection analysis (FIA) method is described for the determination of mitomycin C in the pharmaceutical flacons in this study. Britton-Robinson buffer at pH 7.0 was used as carrier solvent at 1.0 mL/min of flow rate. Mitomycin C signals were detected at 363 nm using UV- spectrophotometric detector. Peak area and peak height signals were used for quantification of mitomycin C and the precision and linearity of the FIA were shown with these signals. The detection limit and determination limit of the method according to criteria of signal to noise 3 were 1.93x1 0`8 M and 6.45x1 0`8 M, respectively. The results obtained with the application of the method were compared to those of high performance liquid chromatography and UV spectrophotometry as standard methods. It was found that the difference of the standard methods and FIA was not statistically significant by using peak area response of FIA. It can be concluded that FIA developed with this study is a precise, accurate, sensitive and cheap method. Keywords: Mitomycin C, Flow-injection analysis, Validation, Flacon.en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectEczacılık ve Farmakolojitr_TR
dc.subjectPharmacy and Pharmacologyen_US
dc.titleMitomisin C`nin sürekli akış enjeksiyon analizi ile miktar tayini, validasyonu ve flakonlarına uygulanması
dc.title.alternativeA Validated method for the determination of mitomycin C by flow injection analysis and its application to flacons
dc.typemasterThesis
dc.date.updated2018-08-06
dc.contributor.departmentAnalitik Kimya Anabilim Dalı
dc.identifier.yokid119120
dc.publisher.instituteSağlık Bilimleri Enstitüsü
dc.publisher.universityANADOLU ÜNİVERSİTESİ
dc.identifier.thesisid116042
dc.description.pages26
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess