Design of a wide Range kVp-meter
dc.contributor.advisor | Ülgen, Ali Yekta | |
dc.contributor.author | Tümer, Murat | |
dc.date.accessioned | 2020-12-23T10:39:39Z | |
dc.date.available | 2020-12-23T10:39:39Z | |
dc.date.submitted | 2007 | |
dc.date.issued | 2018-08-06 | |
dc.identifier.uri | https://acikbilim.yok.gov.tr/handle/20.500.12812/327342 | |
dc.description.abstract | Röntgen görüntülerinin kalitesini belirleyen faktörlerden biri olan kVp ayar heryl mutlaka ölçülmeli ve standartlara göre %5'ten büyük bir sapma varsa yeniden kalibreedilmelidir. Bu çal³mada bir kVp-metre tasarlanm³ ve prototipi üretilmi³, daha sonrada çal³mas kesinlik, duyarlk ve güvenlilirlik açsndan denenmi³tir. Tasarlanrkenmetallerin gelen fotonlarn enerjileri ile, bir anlamda da röntgen tüpünün kVp'si ilede§i³en geçirgenli§inden yararlanlm³tr. Bu prototip üzerinde yaplan ölçümlerde iyisonuçlar elde edilmi³tir. Kesinlik ve duyarlk sapmalarnn %1'in altnda oldu§u tespitedilmi³tir. Tansal radyolojide kullanlan bu ölçüm presibi mamogra cihazlarndada geçerli oldu§undan cihaz mamogra kVp'lerinin ölçümünde de kullanlabilmektedir.Mamogra kipinin ölçüm kesinli§i ve duyarl§nn da %1'in altnda oldu§u ölçülmü³tür.Anahtar Sözcükler: kilovolt peak, röntgen ³n, fotodiyot, bakr süzgeç, do§rusalzayatma katsays, kalibrasyon | |
dc.description.abstract | The kVp setting is one of the major factors aecting the image quality in X-rayimaging and should be annually measured and calibrated if necessary. In this thesis, akVp-meter is designed and a prototype unit was built and the performance was testedin terms of accuracy and reliability. The design is based on the dependency of theattenuation coecient of metals on the energy of the incident photons, which is relatedto kVp. The tests on the prototype showed that the accuracy and precision are bothbelow 1% in the diagnostic range. As the same measuring principle applies for mam-mography unit, this device can be also used for kVp measurements of mammographyunits. The accuracy and precision in the mammography mode are below 1%, too.Keywords: kilovolts peak, X-ray, photodiode, copper lter, linear attenuation coe-cient, calibration. | en_US |
dc.language | English | |
dc.language.iso | en | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Attribution 4.0 United States | tr_TR |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject | Biyomühendislik | tr_TR |
dc.subject | Bioengineering | en_US |
dc.title | Design of a wide Range kVp-meter | |
dc.title.alternative | Geniş bant kVp-metre tasarımı | |
dc.type | masterThesis | |
dc.date.updated | 2018-08-06 | |
dc.contributor.department | Diğer | |
dc.identifier.yokid | 200993 | |
dc.publisher.institute | Biyo-Medikal Mühendislik Enstitüsü | |
dc.publisher.university | BOĞAZİÇİ ÜNİVERSİTESİ | |
dc.identifier.thesisid | 199376 | |
dc.description.pages | 66 | |
dc.publisher.discipline | Diğer |