The effects of skin-tissue morphometry on the mechanical impedance of rat glabrous skin
dc.contributor.advisor | Güçlü, Burak | |
dc.contributor.author | Gök, Çağlar | |
dc.date.accessioned | 2020-12-23T10:38:28Z | |
dc.date.available | 2020-12-23T10:38:28Z | |
dc.date.submitted | 2012 | |
dc.date.issued | 2018-08-06 | |
dc.identifier.uri | https://acikbilim.yok.gov.tr/handle/20.500.12812/327252 | |
dc.description.abstract | Bu tez çalışmasında, sıçan tüysüz derisinde iki farklı noktada (parmak ve ayak tabanı) 61µm genlikli iki farkli frekansta (40 Hz ve 250 Hz) mekanik empedans ölçümleri yapılmıştır. Kuvvet (F), hız (v) ve bunların arasındaki faz farkı(?) mekanikempedans komponentlerini hesaplamak için kaydedilmi³tir. Ayrıca mekanik ölçümlerin alındığı noktalardan deri örnekleri deri katmanlarının morfometrik analizi (toplam deri, toplam epidermis, stratum korneum, canlı epidermis ve dermis kalınlıkları) için histolojik olarak incelenmiştir. Bütün mekanik ve morfometrik ölçümler iki farklı koşul altındagerçekleştirilmiştir: normal koşul ve epidermis-sıyrılmış koşul.Normal koşulda two-way ANOVA sonuçlarına göre, lokasyonun deri direncini istatiksel anlamda az miktarda etkilediği görülmektedir (p=0.056), fakat frekansın istatiksel anlamda bir etkisi görülmemektedir (p=0.376). Frekansın empedans genliği üzerine etkisi istatiksel anlamda önemli bulunmuştur (p=0.018), bununla birlikte lokasyonun istatiksel anlamda bir etkisi görülmemiştir (p=0.684). Normal koşulda, 40 Hz frekansda, parmakda ve ayak tabanında, deri direnci ve stratum korneum kalınlığı arasında istatiksel anlamda önemli ve pozitif yönlü bir korelasyon vardır (r=0.061 p=0.06 parmak için, r=0.94 p<0.0001 ayak tabanı için). Sıyrılmış koşulda, 40 Hzfrekansda, parmakta, kalan epidermis kalınlığı deri direnci, sıkılığı ve empedans genliği ile istatiksel anlamda önemli ölçüde koreledir (r=0.91 p<0.001 deri direnci için,r=0.80 p<0.01 deri sıkılığı için, r=0.90 p<0.001 empedans genli§i için). Ayrıca 40 Hz'de, ayak tabanında, kalan epidermis kalınlığı ve mekanik empedans komponentleri arasında istatiksel anlamda önemli bir korelasyon görülmüştür.Sonuçlara göre, mekanik empedans için deri direnci büyük ölçüde belirleyicidir. Deri direnci 40 Hz'de lokasyondan etkilenmiştir ve deri direnci stratum korneum kalınlığı ile istatiksel anlamda önemli dercede koreledir. Bu duruma göre, stratum korneumun 40 Hz'de derinin mekanik özelliklerini belirledi§i düşünülmektedir. | |
dc.description.abstract | In this thesis, the mechanical impedance of rat glabrous skin was measured at two different locations: the digit and the sole in the hind paw, at two frequencies: 40 Hz and 250 Hz with amplitude of 61 µm. The force (F), the velocity (v) and the phase difference between them (?) were measured to calculate the mechanical impedance components. Skin samples were also studied histologically from the same locations where the impedance measurements were obtained. On the microscope images, morphometrical measurements of the skin layers were performed. All mechanical impedance and morphometrical measurements were done in two different conditions: the normal and the epidermis-peeled condition.In the normal condition, two-way ANOVA showed that the effect of the location on the resistance was marginally significant (p=0.056), whereas the frequency had no effect (p=0.376). The effect of the frequency on the modulus was found to be significant (p=0.018); however, the effect of the location on the modulus was not significant (p=0.684). In the normal condition, there was a significant correlation between the resistance and the stratum corneum thickness at 40 Hz in the sole and marginally in the digit (r=0.61, p=0.06 for the digit; r=0.94, p<0.0001 for the sole). In the peeled condition, at 40 Hz, the remaining epidermis thickness in the digit was significantly correlated with the resistance, the reactance and the modulus (r=0.91, p<0.001 for the resistance; r=0.80, p<0.01 for the reactance; r=0.90, p<0.001 for the modulus). No correlations were found at 250 Hz either on normal and peeled conditions.According to these results, the impedance was found to be largely governed by resistance. The resistance of the skin was affected by the location and it was highly correlated with the stratum corneum thickness at 40 Hz. This suggests that stratum corneum may determine the mechanical properties of the skin at 40 Hz. | en_US |
dc.language | English | |
dc.language.iso | en | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Attribution 4.0 United States | tr_TR |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject | Biyoloji | tr_TR |
dc.subject | Biology | en_US |
dc.subject | Biyomühendislik | tr_TR |
dc.subject | Bioengineering | en_US |
dc.title | The effects of skin-tissue morphometry on the mechanical impedance of rat glabrous skin | |
dc.title.alternative | Deri-doku morfometrisinin sıçan tüysüz derisinin mekanik empedansı üzerinde etkisi | |
dc.type | masterThesis | |
dc.date.updated | 2018-08-06 | |
dc.contributor.department | Biyomedikal Mühendisliği Anabilim Dalı | |
dc.identifier.yokid | 444997 | |
dc.publisher.institute | Biyo-Medikal Mühendislik Enstitüsü | |
dc.publisher.university | BOĞAZİÇİ ÜNİVERSİTESİ | |
dc.identifier.thesisid | 320803 | |
dc.description.pages | 62 | |
dc.publisher.discipline | Diğer |