Prostat kanseri radyoterapi tedavi planlarında hacimsel yoğunluk ayarlı ark tedavisi ve dinamik yoğunluk ayarlı radyoterapi tekniklerinin karşılaştırılması
dc.contributor.advisor | Korcum Şahin, Aylin Fidan | |
dc.contributor.author | Bilek, Yilmaz | |
dc.date.accessioned | 2020-12-02T12:05:39Z | |
dc.date.available | 2020-12-02T12:05:39Z | |
dc.date.submitted | 2018 | |
dc.date.issued | 2019-05-17 | |
dc.identifier.uri | https://acikbilim.yok.gov.tr/handle/20.500.12812/30933 | |
dc.description.abstract | Amaç: Bu çalışmanın amacı prostat kanseri radyoterapi tedavisinde D-IMRT ve VMAT tedavi tekniklerinin dozimetrik olarak karşılaştırılmasıdır.Yöntem: Yüksek riskli 10 prostat kanseri hastasına CMS Monaco TPS kullanılarak Linak tabanlı 9-alan D-IMRT ve çift ark VMAT teknikleri ile planlar tasarlandı. PTV 46, PTV 56 ve PTV 74'e sırasıyla 46, 56 ve 74 Gy doz SIB tekniği ile uygulandı. Her iki teknik ile oluşturulan planlarda aynı doz sınırlamaları kullanıldı. İki planlama tekniği; PTV 46, PTV 56, PTV 74 yapılarındaki doz sarımı ve HI ile CI değerleri bakımından karşılaştırıldı. Kritik organlarda, rektum için V50, V60, V65, V70 değerleri mesane için V65, V70 değerleri, femur başları için ise V40 değerleri incelendi. Her iki teknik ile elde edilen planların tedavi süreleri, segment sayıları ve MU değerleri karşılaştırıldı. Ayrıca hastaların aldığı integral doz olarak V37 değerlendirildi. Elde edilen tüm veriler Wilcoxon testi uygulanarak istatistiksel olarak değerlendirildi.Bulgular: D-IMRT ve VMAT teknikleri ile hedef hacimler için, birbirlerine yakın doz sarımları elde edilmiştir. PTV 74 için hesaplanan HI ve CI değerleri her iki teknikte benzer bulunmuştur. Her iki planlama tekniği ile tüm kritik organlar, doz sınırlamalarının altında tutulabilmiştir. Ayrıca OAR koruması açısından iki teknikten, birbirlerine yakın sonuçlar elde edilmiştir. VMAT tekniği ile oluşturulan planlardan elde edilen segment ve MU sayıları D-IMRT tekniği ile oluşturulan planlara göre fazla olmasına rağmen tedavi süresinin daha kısa olduğu gözlenmiştir (p: 0,005). Sonuç: Prostat kanseri radyoterapi tedavisinde kullanılan 9-alan D-IMRT tekniği ve VMAT tekniklerinden hem PTV sarımları hem kritik organ korumaları açısından benzer dozimetrik sonuçlar elde edilmiştir. Sadece tedavi süresi açısından VMAT tekniğinin D-IMRT tekniğine belirgin bir üstünlüğü gözlenmiştir. | |
dc.description.abstract | Objective: The aim of this study is to compare dosimetric values of D-IMRT and VMAT treatment techniques in the treatment of prostate cancer radiotherapy.Method: Treatment plans were designed for 10 high-risk prostate cancer with Linac based 9-fields D-IMRT and double arc VMAT techniques using CMS Monaco TPS. 46, 56 and 74 Gy doses were prescribed to PTV 46, PTV 56 and PTV 74 as SIB, respectively. The same dose constrains were used in the plans generated by both techniques. Two planning techniques; were compared to HI and CI values as well as the dose coverage of PTV structures. Critical organs were assessed V50, V60, V65, V70 for the rectum, V65, V70 for the bladder and V40 for the femur heads. The treatment times, segment numbers and MU values of the plans obtained with both techniques were compared. V37 was also evaluated as integral dose of the patients. All obtained data were statistically evaluated by Wilcoxon test.Results: With D-IMRT and VMAT techniques, similar dose coverage were obtained for target volumes. HI and CI values calculated for PTV 74 were found to be the similar in both techniques. With both planning techniques, all critical organs could be kept below the dose limits. In addition, in terms of OAR protection, close results were obtained from both techniques. Although the segment and MU numbers obtained from the plans generated by the VMAT technique were higher than the plans generated by the D-IMRT technique, the treatment time was found shorter (p: 0.005).Conclusion: Similar dosimetric results were obtained from 9-fields D-IMRT and VMAT techniques used in the treatment of prostate cancer radiotherapy in terms of PTV dose coverage and critical organ protection. The VMAT technique has an advantage over the D-IMRT technique only in terms of treatment time. | en_US |
dc.language | Turkish | |
dc.language.iso | tr | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Attribution 4.0 United States | tr_TR |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject | Fizik ve Fizik Mühendisliği | tr_TR |
dc.subject | Physics and Physics Engineering | en_US |
dc.subject | Onkoloji | tr_TR |
dc.subject | Oncology | en_US |
dc.title | Prostat kanseri radyoterapi tedavi planlarında hacimsel yoğunluk ayarlı ark tedavisi ve dinamik yoğunluk ayarlı radyoterapi tekniklerinin karşılaştırılması | |
dc.title.alternative | Comparison of volumetric modulated arc therapy and dynamic intensity modulated radiation therapy techniques in prostate cancer radiotherapy treatment plans | |
dc.type | masterThesis | |
dc.date.updated | 2019-05-17 | |
dc.contributor.department | Radyasyon Onkolojisi Anabilim Dalı | |
dc.subject.ytm | Medical physics | |
dc.subject.ytm | Neoplasms | |
dc.subject.ytm | Prostatic neoplasms | |
dc.subject.ytm | Radiotherapy | |
dc.subject.ytm | Radiotherapy-computer assisted | |
dc.subject.ytm | Radiotherapy-intensity-modulated | |
dc.identifier.yokid | 10200356 | |
dc.publisher.institute | Sağlık Bilimleri Enstitüsü | |
dc.publisher.university | AKDENİZ ÜNİVERSİTESİ | |
dc.identifier.thesisid | 520574 | |
dc.description.pages | 89 | |
dc.publisher.discipline | Diğer |