dc.description.abstractAmaç: Bu çalışmada polieter eter keton (PEEK), cam fiber ve zirkonyum oksit post-kor restorasyonların kırılma dayanımlarının ve sonlu elamanlar analizi ile post-kor ve diş kökünde oluşan stres dağılımlarının incelenmesi amaçlanmıştır.Yöntem: Kırılma dayanımı testi için üst santral dişlerde 1.4 mm (dar) ve 1.6 mm (geniş) çapındaki drillerle 7.5 mm (kısa) ve 10 mm (uzun) derinliğinde post boşlukları oluşturuldu (N=120). Post yuvalarına cam fiber, zirkonyum oksit ve PEEK postlar uygulandı (n=10). Örnekler için koping oluşturuldu, simante edildi. Universal test cihazı ile dişin uzun aksına 45 eğimle statik yükleme yapıldı. Sonlu eleman analizi için modellenen üst santral dişin insizal sınırının 2 mm servikalinden ve dişin uzun aksına 45 açı ile 100 N kuvvet uygulandı. Maksimum ve minumum Von Misses stresleri kaydedildi ve stres dağılımını yansıtan görseller elde edildi. Kırılma dayanımı verileri istatistiksel olarak One-Way ANOVA ve LSD testi ile değerlendirildi.Bulgular: Kırılma dayanımları istatistiksel olarak değerlendirildiğinde post boyutları PEEK post korlar için anlamlı fark oluşturmadı (p>0.05). Zirkonyum oksit gruplarda en düşük anlamlı kırılma dayanımı kısa-dar grupta gözlendi. Cam fiber gruplarında en yüksek kırılma dayanımı uzun-geniş grupta bulgulandı. Kısa-geniş grup dışında diğer boyutlarda PEEK'in kırılma dayanımı cam fibere kıyasla anlamlı derecede düşüktü. Post-korlar için maksimum Von Misses değerleri en yüksek PEEK post-korda (32,76 MPa) görüldü. Bu değerler cam fiber ve zirkonyum oksit post için sırasıyla 0,80 MPa ve 21,17 MPa'dı. Diş kökünde oluşan maksimum Von Misses değerleri ise en yüksek cam fiber postlu modelde (72,79 MPa) iken, zirkonyum oksit ve PEEK postlu modellerde sırasıyla 69,01 MPa ve 58,22 MPa'dı.Sonuç: Bu çalışmada PEEK post-korlar yeterli kırılma dayanımı göstermiştir. En yüksek kırılma dayanımı ortalaması cam fiber post gruplarında gözlenmiştir. Sonlu eleman analizi ile değerlendirildiğinde PEEK post-korun diş kökünde oluşturduğu maksimum Von Misses değeri diğer modellere kıyasla daha düşüktü.Anahtar Kelimeler: post-kor, PEEK, CAD/CAM, cam fiber, zirkonyum oksit
dc.description.abstractObjective: The aim of the present study was to investigate the fracture resistance of polyether ether ketone (PEEK), glass fiber and zirconium oxide post-core restorations and stress distributions of post-cores and roots by using finite element analysis (FEA).Method: Post cavities of 7.5 and 10 mm depth were formed with 1.4 and 1.6 mm diameter drills at maxillary central incisors (N=120). Glass fiber, zirconium oxide and PEEK posts were applied to post cavities (n=10). Coping was generated for samples. Static load was applied on the long axis of tooth with 45 inclination with universal tester. FEA 100 N force was applied along to long axis of the tooth at 45 angle. Von Misses stress values were recorded and images were obtained. Fracture resistance data were statistically evaluated by using One-Way ANOVA and LSD test.Results: When fracture resistance were evaluated, the post dimensions didn't show statistically significant difference in PEEK posts (p> 0.05). Among zirconium oxide groups, the lowest fracture resistance was observed in short-narrow group and the result was statistically significant. The highest fracture resistance in glass fiber groups was seen in long-wide groups. The PEEK's fracture resistance was significantly lower than glass fiber in other sizes except short-wide group. The highest Von Misses value of posts was seen in PEEK post-core (32.76 MPa). These values were 0.80 MPa and 21.17 MPa for glass fiber and zirconium oxide post. The highest Von Misses values in roots were in glass fiber post model (72.79 MPa), whereas 69.01 MPa and 58.22 MPa in zirconium oxide and PEEK posts.Conclusion: PEEK posts showed adequate fracture resistance. The highest value of fracture resistance was observed in glass fiber post groups. The highest Von Misses value of root which was caused by PEEK post-core was lower than the all other models.Key words: post-core, PEEK, CAD/CAM, glass fiber, zirconium oxideen_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectDiş Hekimliğitr_TR
dc.subjectDentistryen_US
dc.titleÜç farklı post-kor sisteminin kırılma dayanımlarının incelenmesi ve sonlu eleman analizi ile stres dağılımlarının değerlendirilmesi
dc.title.alternativeInvestigation of the fracture strengths of three different post-core systems and evaluation of the stress distribution using finite element analysis
dc.typedoctoralThesis
dc.date.updated2020-03-04
dc.contributor.departmentProtetik Diş Tedavisi Anabilim Dalı
dc.subject.ytmDental materials
dc.subject.ytmDental restoration
dc.subject.ytmDental stress analysis
dc.subject.ytmFinite elements stress analysis
dc.subject.ytmCAD/CAM
dc.subject.ytmZirconium oxide
dc.subject.ytmPost and core technique
dc.identifier.yokid10263116
dc.publisher.instituteSağlık Bilimleri Enstitüsü
dc.publisher.universityAKDENİZ ÜNİVERSİTESİ
dc.identifier.thesisid556856
dc.description.pages138
dc.publisher.disciplineDiğer