dc.contributor.advisor | Topal, Fatih Esad | |
dc.contributor.author | Bilgin, Serkan | |
dc.date.accessioned | 2020-12-10T12:18:35Z | |
dc.date.available | 2020-12-10T12:18:35Z | |
dc.date.submitted | 2017 | |
dc.date.issued | 2018-08-06 | |
dc.identifier.uri | https://acikbilim.yok.gov.tr/handle/20.500.12812/282144 | |
dc.description.abstract | Çalışmamızda level1 hipovolemik şoklu hasta yönetiminde yeni bir yaklaşım olan inferior vena cava/abdominal aort oranının ultrason ile ölçümünün sonuçları değerlendirilmiştir.Bu amaçla Kızılay Kan Merkezi'ne gönüllü olarak kan vermeye gelen kişiler arasından 18-55 yaş arasında, 45 kilogram ağırlığının üstünde,herhangi bir hastalık öyküsü,herhangi bir tedavi öyküsü ve herhangi bir mental hastalığı olmayan kişiler arasından prospektif olarak incelenmişlerdir. Başvuran bağışçılarda bağış öncesi ultrason ölçümleri, bağış sonrası ultrason ölçümleri ve sıvı resüstasyonu sonrası ultrason ölçümleri yapılmış ve bu ölçümler karşılaştırılmıştır.Bulgulara bakıldığında 29 erkek(%74.4) 10 kadın(%25.6) toplamda 39 kişi ile bu çalışma yapılmıştır. Ortalama yaş dağılımı erkekler için 30,93±6,73 iken kadınlarda yaş dağılımı 30,2±7,86 olarak değerlendirilmiştir. Bağışçıların kan bağışı öncesi ortalama vena cava inferior(VCI) çap ölçümleri 17,32±0,39 mm iken bağış sonrası ortalama ölçümleri ise16,15±0,51 mm (p<0,001) olarak değerlendirilmiştir. Donörlere verilen 500 cc serum fizyolojik sonrası yapılan ölçümlerde VCI çapı ortalama değerleri 17,11±0,38 mm (p<0.05) olarak değerlendirilmiş ve her iki durumda da VCI çap değişiklikleri istatiksel olarak anlamlı bulunmuştur. Aynı şekilde bağış öncesi ortalama abdominal aorta(AA) çapının ölçümleri 14,18±0,28 mm iken bağış sonrası ortalama ölçümleri 14,1±0,22 mm (p< 0.001) olarak ölçülmüş ve istatiksel olarak anlamlı bir sonuç elde edilmiştir. Serum fizyolojik verilmesi sonrası ortalama AA ölçümleri ise 14,09±0,14 mm (p>0.05) olarak değerlendirilmiştir ve istatistiksel olarak anlamlı bir fark kan kaybı sonrası sıvı resüstasyonu ile AA çapında bulunamamıştır.VCI/AA çap indeksi, ortalama VCI çapının ortalama AA çapına matematiksel olarak bölünmesi ile elde edilmiştir. Bağış öncesi VCI/AA çap indeks ortalaması 1,22±0,04 mm iken bağış sonrası indeks oranı 1,14±0,04 mm olarak ölçülmüştür. Donörlere verilen 500 cc serum fizyolojik sonrası VCI/AA çap indeksi ise 1,21±0,03 mm olarak hesaplanmıştır. | |
dc.description.abstract | In our study, we evaluated the results of ultrasound measurement of inferior vena cava / abdominal aortic ratio for a new approach in level 1 hypovolemic shock patient management.For that purpose, among people who came to Kızılay Blood Transfusion Center voluntarily between the ages of 18-55, more than 45 kg weighted, have no story of illnesses, treatment or mental illness had been examined prospectively. For the donator applicants, ultrasonic measurements before the donation, ultrasonic measurements after the donation and ultasonic measurements after the fluid resuscitation had been done and these measurements had been compared.According to the results, the study had been done with 29 men (%74,4) 10 women (%25.6) total 39 people. It had been evaluated that mean age distribution for men were 30,93±6,73, while average age distribution for women were 30,2±7,86. It had also evaluated that the diameter measurements of the donators' vena cava inferior (VCI) before the blood transfusion was 17,32±0,39 mm, while it was 16,15±0,51 mm (p<0,001) after the blood transfusion. It had evaluated that after the measurements of 500 cc normal saline given to the donators, the mean rate of VCI diameter was 17,11±0,38 mm (p<0.05) In both of the cases, the diameter differences of VCI had been found significant statistically. In the same way It had measured that the measurement of the mean abdominal aorta (AA) diameter before the donation was 14,18±0,28 mm while it was 14,1±0,22 mm (p< 0.001) after the donation and a significant result had been received statistically. Also, it was evaluated that the mean AA measurements after the normal saline was 14,09±0,14 mm (p>0.05) and statistically there was no difference between the fluid resuscitation and AA after the loss of blood.The VCI/AA diameter index had been obtained by the division of the mean VCI diameter with the AA diameter mathematically. It was measured that the mean VCI/AA diameter index was 1,22±0,04 mm before the donation while it was 1,14±0,04 mm after the donation. It was measured that the diameter index given to the donors after the 500 cc normal saline was also 1,21±0,03 mm As a result, in that study with the mathematical calculation among the Level 1 hypovolemic shocked patients VCI/AA threshold value was measured as 1,14 mm. The rates under this measure might be the symptom of early hypovolemic shock according to our study. | en_US |
dc.language | Turkish | |
dc.language.iso | tr | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Attribution 4.0 United States | tr_TR |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject | İlk ve Acil Yardım | tr_TR |
dc.subject | Emergency and First Aid | en_US |
dc.title | Level1 hipovolemik şoklu hasta yönetiminde yeni bir yaklaşım inferior vena cava/abdominal aort oranının ultrason ile ölçümü | |
dc.title.alternative | The measurement with ultrasound of a new approach for inferior vena cava/abdominal aorta under level 1 hypovolemic shocked patient | |
dc.type | doctoralThesis | |
dc.date.updated | 2018-08-06 | |
dc.contributor.department | Acil Tıp Anabilim Dalı | |
dc.subject.ytm | Hypovolemia | |
dc.subject.ytm | Ultrasonography | |
dc.subject.ytm | Shock | |
dc.subject.ytm | Emergency medicine | |
dc.subject.ytm | Emergency service | |
dc.subject.ytm | Aorta-abdominal | |
dc.subject.ytm | Vena cava inferior | |
dc.identifier.yokid | 10169705 | |
dc.publisher.institute | İzmir Atatürk Eğitim ve Araştırma Hastanesi | |
dc.publisher.university | İZMİR KATİP ÇELEBİ ÜNİVERSİTESİ | |
dc.type.sub | medicineThesis | |
dc.identifier.thesisid | 484628 | |
dc.description.pages | 74 | |
dc.publisher.discipline | Diğer | |