dc.description.abstractAmaç: Projenin amacı akciğer tüberkülozu kuşkusu olan hastaların solunum yolu örneklerinin mikroskobik incelemesinde LED floresan mikroskopi (LED FM) ile Erlich Ziehl Nelseen (EZN) boyama yöntemini karşılaştırmak ve kültür sonuçları referans alınarak LED FM'nin performansını araştırmaktır.Gereç ve Yöntem: Araştırmada Şubat 2018-Aralık 2019 döneminde Manisa Celal Bayar Üniversitesi Hafsa Sultan Hastanesi Tüberküloz Laboratuvarında akciğer tüberkülozu ön tanılı hastalardan alınan solunum yolu örnekleri incelenmiştir. NALC-NaOH yöntemi ile işlenen örneklerden ikişer yayma hazırlanmış ve yaymalar iki okuyucu tarafından kör olarak hem EZN hem de LED FM ile incelenmiştir. Performans değerlendirmesinde kültür sonuçları referans alınmıştır.Bulgular: Araştırmada 1499 solunum yolu örneği değerlendirilmiştir. Örneklerin 134'ünün (%8.9) kültüründe mikobakteri üremiştir. Kültür sonuçları referans alındığında LED FM'nin duyarlılığı %64,2, özgüllüğü %96, pozitif prediktif değeri %61.4 ve negatif prediktif değeri %96.5 bulunmuştur. EZN yönteminin duyarlılığı ise %51.5, özgüllüğü %99.9, pozitif prediktif değeri %97.2 ve negatif prediktif değeri %95.4'dir. Ancak LED FM'de yayma şüpheli, kültür negatif (54/1365) sonuçlar EZN'den (0/1365) anlamlı olarak yüksek bulunmuştur. Bunun nedeninin okuyucuların deneyim eksikliğine bağlı olduğu düşünülmüştür. LED FM inceleme süresi %69 zaman tasarrufu sağlanmıştır. LED floresan mikroskopların maliyetleri yüksek olmakla birlikte florokrom boyama maliyeti EZN boyama yönteminden ucuz bulunmuştur. Okuyucular arasındaki uyum iyi derecede bulunmuş ve okuyuculara yapılan anket sonucu rutin incelemede LED FM tercih edilebileceği belirlenmiştir. Sonuç: LED FM'nin duyarlılığı EZN'den %12.7 daha yüksek bulunmuştur. Ancak yanlış pozitif sonuç oranının yüksek olması nedeni ile LED FM'nin okuyuculara gerekli eğitim verildikten sonra kullanıma girmesi gereklidir. LED FM'nin ülkemizde büyük ölçekli laboratuvarlarda kullanılmasının maliyet etkin olacağı düşünülmüştür.
dc.description.abstractAim: The aim of the Project is to compare of the results of LED fluorescent microscopy (LED FM) and Erlich Ziehl Nelseen (EZN) staining in the examination of the respiratory specimens and to evaluate the performance of LED fluorescent microscopy with culture. Materials and Methods: In the study, the respiratory specimens obtained from patients prediagnosed with pulmonary tuberculosis were examined in the Tuberculosis Laboratory of Manisa Celal Bayar University Hafsa Sultan Hospital between February 2018 and November 2019. Two smears from each specimen processed with NALC-NaOH method were prepared and they were evaluated both EZN and LED FM by blind readers. The results of culture were used as reference for determination of the performance of LED FM.Results: In the study 1499 respiratory specimens were evaluated with LED FM. Mycobacteria were grown in the culture of 134 specimens (8.9%). When the culture was accepted as reference method, the sensitivity, specificity, positive predictive value and negative predictive value of LED FM were found as 64.2%, 96%, 61.4% and 96.5%, respectively. However scarce positive-culture negative results (54/1365) with LED FM were obtained significantly higher than the results with EZN (0/1365). The reason of this was thought to be due to the lack of the experience of the readers. The reading time of LED FM was 69% time saving. While the costs of LED fluorescent microscopes are high, the cost of fluorescent stains found to be cheaper than the EZN staining method. The consistency between the readers was found to be good and it was determined that LED FM could be preferred in routine examination as a result of the survey conducted to the readers.Conclusions: The sensitivity of LED FM was found 12.7% higher than the sensitivity of EZN. However, because of the high rate of false positive results, the introduction of LED-FM should be accompanied by appropriate training of the readers. It is also thought that the use of LED FM will be cost-effective in large-scale laboratories in our country.en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectMikrobiyolojitr_TR
dc.subjectMicrobiologyen_US
dc.titleTüberküloz tanısında led floresan mikroskopinin performansının değerlendirilmesi
dc.title.alternativeEvaluation of the performance of led fluorescent microscopy in diagnosis of tuberculosis
dc.typedoctoralThesis
dc.date.updated2020-06-01
dc.contributor.departmentTıbbi Mikrobiyoloji Anabilim Dalı
dc.identifier.yokid10332588
dc.publisher.instituteTıp Fakültesi
dc.publisher.universityMANİSA CELÂL BAYAR ÜNİVERSİTESİ
dc.type.submedicineThesis
dc.identifier.thesisid622175
dc.description.pages73
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess