Farklı iletken maddelerin elektrikli pulpa testinin cevabına etkisi
dc.contributor.advisor | Bayram, Hüda Melike | |
dc.contributor.author | Demir Şerefli, Emine | |
dc.date.accessioned | 2020-12-10T11:06:11Z | |
dc.date.available | 2020-12-10T11:06:11Z | |
dc.date.submitted | 2019 | |
dc.date.issued | 2019-10-21 | |
dc.identifier.uri | https://acikbilim.yok.gov.tr/handle/20.500.12812/255527 | |
dc.description.abstract | Amaç: İletken materyal olarak su bazlı jeller ve diş macunları olarak iki grup materyal (Colgate Total diş macunu, Tebodont diş macunu, Flor jeli, Ultrason jeli ve Klorheksidin jeli) kullanılmasının ve cinsiyetin elektrikli pulpa testinin cevabına etkisini karşılaştırmaktır.Önemi: Elektrikli pulpa testinde kullanılan iletken maddenin ve cinsiyetin testin cevabına etkisi, dişlere doğru teşhis koymamızda önemlidir.Yöntem: Farklı iletken maddelerin ve cinsiyetin elektrikli pulpa testinin cevabına etkisini incelemek için 20 erkek, 20 kadın toplam 40 sağlıklı gönüllünün sağlıklı 40 üst keser dişi seçildi. Colgate Total, Tebodont, Flor jeli, Ultrason jeli ve Klorjeksidin jel iletken materyal olarak her dişe sırasıyla uygulanmıştır.Verilerin istatistiksel değerlendirilmesi IBM SPSS Versiyon 21.0 yazılımı kullanılarak, One-Sample Kolmogrov-Smirnov, Mann-Whitney U, Friedman ve Bonferroni düzeltmeli Wilcoxon testleriyle yapıldı.Bulgular: Pulpal duyu eşikleri açısından karşılaştırıldığında flor jeli; colgate, tebodont ve klorheksidin jelden (p<0.001, p<0.001 ve p=0.001) anlamlı derecede daha düşük eşik değerine sahipti. Ultrason jeliyle aralarında anlamlı farklılık bulunmamıştır. Colgate, tebodonttan (p=0.005 ) anlamlı derecede daha düşük eşik değerine sahipken ultrason jeli (p=0.001) ile karşılaştırıldığında anlamlı derecede daha yüksek eşik değeri gösterdi. Colgate ile chx jel arasında anlamlı bir farklılık bulunmadı. Tebodont; chx jel ve ultrason jeli karşılaştırıldığında (p<0.001) anlamlı düzeyde daha yüksek eşik değerine sahipti. Chx jel ve ultrason jeli arasında istaistiksel olarak anlamlı bir fark bulunmadı (p=0,013).Sonuç: Sonuç olarak su bazlı jel gruplarının diş macunlarından daha iyi bir iletkenliğe sahip olduğu ve cinsiyetin eşik değere anlamlı etkisi olmadığı bulunmuştur.Anahtar kelimeler: Elektrikli pulpa testi, pulpa eşik değeri, iletken madde | |
dc.description.abstract | Aim: To compare the effect of using two groups of materials (Colgate Total toothpaste, Tebodont toothpaste, Fluorine gel, Ultrasound gel and Chlorhexidine gel) which water-based gels and toothpastes as conductive materials and the effect of gender on electrical pulp testing.Importance: The effect of the conductive materials and gender is important for correct diagnosis on response of electrical pulp testing. Method: To investigate the effect of different conductive materials and gender on the response of electrical pulp test, 40 maxillary central tooth of 40 healthy volunteers (20 male and 20 female) were selected. Colgate Total, Tebodont, Fluorine gel, Ultrasound gel and Chlorjexidine gel were applied to each tooth respectively as the conductive material. The statistical evaluation was performed using the IBM SPSS Version 21.0 software, with the One-Sample Kolmogrov-Smirnov, Mann-Whitney U, Friedman and Bonferroni-corrected Wilcoxon tests. Results: In terms of pulpal sensory thresholds, fluorine gel; colgate, tebodont and chlorhexidine gel (p<0.001, p<0.001 and p=0.001) had significantly lower threshold value. No significant difference was found between ultrasound gel and fluorine gel. Colgate had a significantly lower threshold than tebodont (p=0.005), but significantly higher threshold than ultrasound gel (p=0.001). No significant difference was found between Colgate and chx gel. Tebodont; compared with chx gel and ultrasound gel (p<0.001), it had significantly higher threshold value. No statistically significant difference was found between Chx gel and ultrasound gel (p=0.013). It was found that water-based gel groups had better conductivity than toothpastes and gender had no significant effect on threshold value. Key words: Electrical pulp test, pulp threshold, conductive material | en_US |
dc.language | Turkish | |
dc.language.iso | tr | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Attribution 4.0 United States | tr_TR |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject | Diş Hekimliği | tr_TR |
dc.subject | Dentistry | en_US |
dc.title | Farklı iletken maddelerin elektrikli pulpa testinin cevabına etkisi | |
dc.title.alternative | The effect of different conductive materials on response of electrical pulp test | |
dc.type | doctoralThesis | |
dc.date.updated | 2019-10-21 | |
dc.contributor.department | Endodonti Anabilim Dalı | |
dc.subject.ytm | Conductors | |
dc.subject.ytm | Conductivity | |
dc.subject.ytm | Dental pulp | |
dc.subject.ytm | Toothpaste | |
dc.subject.ytm | Diagnostic tests | |
dc.identifier.yokid | 10236943 | |
dc.publisher.institute | Diş Hekimliği Fakültesi | |
dc.publisher.university | TOKAT GAZİOSMANPAŞA ÜNİVERSİTESİ | |
dc.type.sub | dentistThesis | |
dc.identifier.thesisid | 536776 | |
dc.description.pages | 81 | |
dc.publisher.discipline | Diğer |